Cleveland PS130W Operating Instructions And Owner's Manual

Cleveland PS130W Operating Instructions And Owner's Manual

Wood pellet fire stove
Table of Contents

Advertisement

Available languages

Available languages

INSTALLER: Leave this manual with the appliance.
READ INSTRUCTIONS CAREFULLY: Please read this entire manual before installation and use of this
pellet fuel-burning room heater. Failure to follow these instructions could result in property damage, bodily
injury or even death. Do not allow anyone who has not read these instructions to assemble, light, adjust or
operate the stove. Place instructions in a safe place for future reference.
PS60W (F500200)
PS130W (F500205)
THE AUTHORITY HAVING JURISDICTION (SUCH AS MUNICIPAL BUILDING DEPARTMENT, FIRE
DEPARTMENT, FIRE PREVENTION BUREAU, ETC.) SHOULD BE CONSULTED BEFORE INSTALLATION
TO DETERMINE ANY NEED TO OBTAIN A PERMIT. OBSERVE ALL LOCAL BUILDING CODES.
OPERATING INSTRUCTIONS
AND OWNER'S MANUAL
WOOD PELLET FIRE STOVE
Cleveland Ironworks a subsidiary of Enerco Group Inc.
4560 West 160th st Cleveland, Ohio 44135 1-800-251-0001
CONSUMER: Save these Instructions for future reference.
Model #
PS60W
PS130W
PSBF66W
PSBF66W (F500210)
Apple Store
Google Play Store
66688 REV F

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PS130W and is the answer not in the manual?

Questions and answers

Tim Sweeney
February 1, 2025

Need to know center height of exhaust port please. Stove I'm replacing is 11 7/8"

Subscribe to Our Youtube Channel

Summary of Contents for Cleveland PS130W

  • Page 1 DEPARTMENT, FIRE PREVENTION BUREAU, ETC.) SHOULD BE CONSULTED BEFORE INSTALLATION TO DETERMINE ANY NEED TO OBTAIN A PERMIT. OBSERVE ALL LOCAL BUILDING CODES. Cleveland Ironworks a subsidiary of Enerco Group Inc. 4560 West 160th st Cleveland, Ohio 44135 1-800-251-0001 66688 REV F...
  • Page 2: Table Of Contents

    SMART STOVE WIFI CONNECTION ............15 WIFI CONTROLS ................16 MULTI FUNCTION CONTROLS ............17 MANUAL STOVE OPERATION ............18 MAINTENANCE ................19 WIRING DIAGRAM ................27 SERVICE PARTS ................28 Cleveland Iron Works Wood Pellet Fire Stove Operating Instructions and Owner’s Manual...
  • Page 3: Specifications

    [Amperes] Auger Motor R.P.M. This manual describes the installation and operation of the brand “Cleveland Iron Works” wood pellet fire stove. This stove meets the applicable U.S. Environmental Protection Agency’s emission limits for pellet fired heaters sold after 2020. Under specific test conditions these stoves have been shown to deliver heat at rates ranging from:...
  • Page 4: Getting Started

    “L” or “PL” which is listed to UL 641, ULC S609 (Standard for 650°C Factory-Built Chimneys), or ULC/ORD C441. Install per chimney manufacturer’s instructions (see page 9) Cleveland Iron Works Wood Pellet Fire Stove Operating Instructions and Owner’s Manual...
  • Page 5: Safety Precautions

    For auxiliary information regarding pellet stove safety and operation information contact the National Fire Protection Association (NFPA) by mail at: NFPA, Batterymarch Park, Quincy, MA 02269 or visit the NFPA website: https://www.nfpa.org/ Cleveland Iron Works Wood Pellet Fire Stove Operating Instructions and Owner’s Manual...
  • Page 6: Clearance To Combustibles

    • It has at least 13” (330 mm) of clearance from the protecting the floor area underneath the stove. each side to the nearest body. Cleveland Iron Works Wood Pellet Fire Stove Operating Instructions and Owner’s Manual...
  • Page 7 See Figure 2 or 3. Cleveland Iron Works Wood Pellet Fire Stove Operating Instructions and Owner’s Manual...
  • Page 8: Installation

    80 inches (203 cm), of an electrical outlet. Lay the power cord out such that it will not come into contact with the stove’s surface. Cleveland Iron Works Wood Pellet Fire Stove Operating Instructions and Owner’s Manual...
  • Page 9 • Class A listed chimney complying with the requirements for Type HT chimneys in the Standard Figure 6 for Chimneys, Factory-Built, Residential Type and ONLY APPROVED CANADIAN WALL PASS Building Heating Appliance, UL 103. THROUGH Cleveland Iron Works Wood Pellet Fire Stove Operating Instructions and Owner’s Manual...
  • Page 10 24 gauge thickness. Fasteners used to secure chimney section shall not penetrate chimney flue liner. Cleveland Iron Works Wood Pellet Fire Stove Operating Instructions and Owner’s Manual...
  • Page 11: Additional Mobile Home Requirements

    • The stove must be provided a permanently ducted source of outside air to support combustion which meets the following requirements: — The duct must be made of metal exclusively, not other materials such as plastic. Cleveland Iron Works Wood Pellet Fire Stove Operating Instructions and Owner’s Manual...
  • Page 12 Do not mix brands of components for the same ventilation system. The following figures illustrate various methods and requirements of using a manufactured chimney and connection pipes to vent the stove. Cleveland Iron Works Wood Pellet Fire Stove Operating Instructions and Owner’s Manual...
  • Page 13: Operation

    NOT TOUCH THE STOVE. KEEP CHILDREN, • The pellets should be less then 30mm long, with a CLOTHING AND FURNITURE AWAY. diameter between 5 and 6.5 mm. CONTACT MAY CAUSE SKIN BURNS. Cleveland Iron Works Wood Pellet Fire Stove Operating Instructions and Owner’s Manual...
  • Page 14 Creosote formation and removal. To slow the build can take 5 to 15 minutes depending on the model up of creosote within your chimney burn only the of stove. recommended fuel, see page 13. Cleveland Iron Works Wood Pellet Fire Stove Operating Instructions and Owner’s Manual...
  • Page 15: Smart Stove Wifi Connection

    Note: On the PS60W and PS130W, you must remove Auto side panel to access rear of display panel. Refer to Removing Back & Side Panel in the Maintenance section.
  • Page 16: Wifi Controls

    • P1 [Maximum Power] Settings configurations scheduled • P2 [Medium Power] Settings Figure 17 Wifi Controls operation • P3 [Low Power] Settings • P4 [Minimum Power] Settings Cleveland Iron Works Wood Pellet Fire Stove Operating Instructions and Owner’s Manual...
  • Page 17: Multi Function Controls

    PS60W, PS130W, AND PSBF66W MULTI FUNCTION CONTROLS Manual / Automatic Wireless Connection Confirm Rate Select Notification Light Notification Light Up Selector MULTI FUNCTION DISPLAY Display Screen Settings Time Power Down Selector Figure 18a Mounted Multi Function Controls Panel Press to cycle between temperature reports...
  • Page 18: Manual Stove Operation

    Note: Each box represents an hour of the day over a 24 hour period. The first box is 00:00 (Midnight) and the last box is 23:00 (11 PM). 5. Press the Settings button to go back to home. Cleveland Iron Works Wood Pellet Fire Stove Operating Instructions and Owner’s Manual...
  • Page 19: Maintenance

    Figure 20 Outlet Duct Cleveland Iron Works Wood Pellet Fire Stove Operating Instructions and Owner’s Manual...
  • Page 20 During start manufacturer. See pages 29 through 32. up, shut down, and erroneous operation of the stove incomplete combustion can produce ash, soot, and Cleveland Iron Works Wood Pellet Fire Stove Operating Instructions and Owner’s Manual...
  • Page 21 Pull the hot surface igniter free, and install replacement service part. See Figure 22 and 24. Figure 22 Igniter Disassembly Cleveland Iron Works Wood Pellet Fire Stove Operating Instructions and Owner’s Manual...
  • Page 22 1. Vacuum Pressure Switch: A safety vacuum switch is • To remove the PS130W rear plate, remove the 8 located behind the left door, fastened to the base. screws securing it at the bottom and rear of the If a low pressure is created in the firebox by a leak, stove.
  • Page 23 1. Check wires and connection points. Open circuit at temperature sensor #1 ESO1 2. Replace Motherboard. Short circuit at sensor #2, hopper 1. Check wires and connection points. ESC2 temperature 2. Replace Motherboard. Cleveland Iron Works Wood Pellet Fire Stove Operating Instructions and Owner’s Manual...
  • Page 24 2. Check that the auger is not blocked. If it is jammed, or with pellets. blocked, remove the cause of the jamming. disconnected. 3. Check that the auger screw fastening the auger to the motor is secure. Cleveland Iron Works Wood Pellet Fire Stove Operating Instructions and Owner’s Manual...
  • Page 25 4. Increase the cross sectional area of the ducting. 5. Increase the fan’s speed to increase the rate of combustion. 6. Contact the manufacturer for assistance. Cleveland Iron Works Wood Pellet Fire Stove Operating Instructions and Owner’s Manual...
  • Page 26 Heat exchange tubes or flue pass is Clean the heat exchanger tubes or flue pass. dirty. Cleveland Iron Works Wood Pellet Fire Stove Operating Instructions and Owner’s Manual...
  • Page 27: Wiring Diagram

    NOTE: IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 105 °C AND RATED FOR 600V Cleveland Iron Works Wood Pellet Fire Stove Operating Instructions and Owner’s Manual...
  • Page 28 Cleveland Iron Works Wood Pellet Fire Stove Operating Instructions and Owner’s Manual...
  • Page 29 Cleveland Iron Works Wood Pellet Fire Stove Operating Instructions and Owner’s Manual...
  • Page 30: Service Parts

    Vacuum Switch 66651 Ash Pan Lock Parts 66660 Auger Assembly 66640 Igniter Ground Screw 66617 Hopper Lid Switch 66641 Combustion Blower 66652 Magnet 66612 Circulation Blower 66653 Door, Latch Cleveland Iron Works Wood Pellet Fire Stove Operating Instructions and Owner’s Manual...
  • Page 31 THIS PAGE INTENTIONALLY LEFT BLANK ESTA PÁGINA INTENCIONALMENTE SE DEJA EN BLANCO CETTE PAGE A ÉTÉ INTENTIONNELLEMENT LAISSÉE VIERGE Cleveland Iron Works Wood Pellet Fire Stove Operating Instructions and Owner’s Manual...
  • Page 32 Please include the model number, date of purchase, and description of problem in all communication. LIMITED WARRANTY Enerco Group, Inc. (EGI) warrants Cleveland Iron Works Wood Pellet Fire Stoves to be free from imperfections in workmanship or material, at the date of manufacture. After installation, If covered components are found...
  • Page 33 DANS VOTRE LOCALITÉ (AUTORITÉS DE PRÉVENTION DES INCENDIES, SERVICE DE LA CONSTRUCTION MUNICIPAL, ETC.). RESPECTEZ TOUS LES CODES DE LA CONSTRUCTIONS LOCAUX. Cleveland Ironworks une filiale de Enerco Group Inc. 4560 West 160th st Cleveland, Ohio 44135 1-800-251-0001 66688 REV F...
  • Page 34 Le présent manuel décrit la procédure d’installation et de fonctionnement des poêles à grenailles de bois Cleveland Ironworks. Votre poêle est conforme aux limites d’émission de l’EPA (Environmental Protection Agency) des États-Unis pour les poêles à grenailles fabriqués après l’année 2020. Sous des conditions d’essai précises, il a été...
  • Page 35: Spécifications

    ** Selon la zone climatique. Les différences de climat et la localisation affectent les attributs comme le rendement du poêle et la production de monoxyde e carbone. Guide du propriétaire et intructions d’utlisation Cleveland Iron Works Poêle à grenailles de bois...
  • Page 36: Commencer

    UL 641, ULC S609 (Norme « Standard for 650°C Factory- Built Chimneys »), ou ULC/ORD C441. Installer selon les instructions du fabricant de cheminée (voir page 9) Cleveland Iron Works Poêle à grenailles de bois Guide du propriétaire et intructions d’utlisation...
  • Page 37: Précautions De Sécurité

    NFPA (National Fire Protection Association), par la poste, à : NFPA, Batterymarch Park, Quincy, MA 02269, U.S.A. ou visitez le site Web de la NFPA : https://www.nfpa.org/ Guide du propriétaire et intructions d’utlisation Cleveland Iron Works Poêle à grenailles de bois...
  • Page 38: Distances De Dégagement Des Matériaux Combustibles

    51 mm (2 po) sur les côtés. De plus, le poêle à grenailles de bois devra être positionné suffisant pour protéger le plancher sous le poêle. de sorte : Cleveland Iron Works Poêle à grenailles de bois Guide du propriétaire et intructions d’utlisation...
  • Page 39 être inséré adéquatement dans le poêle pour que l’allumeur puisse entrer en contact avec les grenailles. Voir figure 2 ou 3. Figure 5 Poignée de porte Guide du propriétaire et intructions d’utlisation Cleveland Iron Works Poêle à grenailles de bois...
  • Page 40: Installation

    LA STRUCTURE DE LA MAISON. (6,5 pi) sur le mur derrière le poêle. Placer le cordon d’alimentation de façon qu’il ne vienne en contact avec la surface du poêle. Cleveland Iron Works Poêle à grenailles de bois Guide du propriétaire et intructions d’utlisation...
  • Page 41 HT de la norme UL 103 (Standard for Chimneys, SEULEMENT UN TUYAU DE TRAVERSÉE Factory-Built, Residential Type and Building Heating CONFORME AUX NORMES CANADIENNES Appliance) Guide du propriétaire et intructions d’utlisation Cleveland Iron Works Poêle à grenailles de bois...
  • Page 42 à deux montants d’acier de calibre minimum n 24. La quincaillerie de fixation de la section de cheminée ne doit pas perforer sa paroi interne. Cleveland Iron Works Poêle à grenailles de bois Guide du propriétaire et intructions d’utlisation...
  • Page 43: Exigences Supplémentaires Pour Les Maisons Mobiles

    Boulonné au plancher niveau de façon permanente pour ne pas qu’il Figure 11 Cheminée verticale de maison mobile puisse être déplacé, être basculé ou placé de façon Guide du propriétaire et intructions d’utlisation Cleveland Iron Works Poêle à grenailles de bois...
  • Page 44 Cheminée pré-fabriquée traversant même système d’aération. un grenier Les illustrations ci-dessous montrent différentes méthodes et exigences d’utilisation de cheminée pré- fabriquée et des tuyaux de raccordement au poêle Cleveland Iron Works Poêle à grenailles de bois Guide du propriétaire et intructions d’utlisation...
  • Page 45: Fonctionnement

    (moins de 1 %) • Les grenailles devraient être de moins de 30 mm de long et de diamètre entre 5 et 6,5 mm. Guide du propriétaire et intructions d’utlisation Cleveland Iron Works Poêle à grenailles de bois...
  • Page 46 : qu’elles correspondent aux exigences de votre poêle telles • Cycle de nettoyage : Le pot de combustion est nettoyé qu’indiquées à la page 3. Cleveland Iron Works Poêle à grenailles de bois Guide du propriétaire et intructions d’utlisation...
  • Page 47: Connexion Wi-Fi " Smart Stove

    Remarque : Sur les modèles PS60W et PS130W, vous devez retirer le panneau latéral pour accéder à l’arrière du panneau d’affichage. Reportez-vous à la section Auto Retrait du panneau arrière et latéral dans la section...
  • Page 48: Commandes Wi-Fi

    • P2 [réglage de chauffage intermédiaire] Figure 17 Commandes Wi-Fi horaire du poêle • P3 [réglage de chauffage bas] • P4 [réglage de chauffage minimum] Cleveland Iron Works Poêle à grenailles de bois Guide du propriétaire et intructions d’utlisation...
  • Page 49: Commandes Multifonctions

    COMMANDES MULTI-FONCTIONS POUR PS60W, PS130W ET PSBF66W Témoin d’avis Manuel/Automatique Témoin d’avis de connexion Sélecteur Confirmer Sélection de taux Wi-Fi d’accroissement MULTI FUNCTION DISPLAY Afficheur Paramètres Minuterie Sélecteur de décroissement Alimentation Figure 18a Panneau multi-fonction monté Actionner pour faire défiler les lectures de Alimentation température (en °...
  • Page 50: Opération Manuelle Du Poêle

    SÉLECTION DU TAUX visibles. (« RATE SELECT ») 3. Utilisez le bouton Time pour changer la journée. Cleveland Iron Works Poêle à grenailles de bois Guide du propriétaire et intructions d’utlisation...
  • Page 51: Entretien

    Assurez-vous de replacer le pot de combustion dans la bonne orientation de sorte que les grenailles puissent être alimentées et allumées sans problème. Figure 20 Canalisation de sortie Guide du propriétaire et intructions d’utlisation Cleveland Iron Works Poêle à grenailles de bois...
  • Page 52 Des cendres, de la suie et de la créosote peuvent se remplacement de la porte complète fournie par le produire durant le démarrage, l’extinction et le mauvais fabricant. Voir pages 29 àthrough 32. Cleveland Iron Works Poêle à grenailles de bois Guide du propriétaire et intructions d’utlisation...
  • Page 53 Sortir l’allumeur et le remplacer par le nouveau. Voir les figures 22 et 24. Figure 22 Démontage de l’allumeur Guide du propriétaire et intructions d’utlisation Cleveland Iron Works Poêle à grenailles de bois...
  • Page 54 Figure 26 Ventilateur d’échappement du modèle • Pour retirer les panneaux latéraux du modèle PSBF66W PS130W, retirer les vis de fixation à l’arrière de l’unité et faire glisser le panneau vers l’arrière. COMPOSANTS DE SÉCURITÉ • Pour retirer la plaque arrière du modèle PS130W, Pressostat de vide : Un pressostat de vide est fixé...
  • Page 55 2. Remplacer la carte mère. Capteur de température n 2 en 1. Vérifier les fils et les points de raccordement. ESO2 2. Remplacer la carte mère. circuit ouvert Guide du propriétaire et intructions d’utlisation Cleveland Iron Works Poêle à grenailles de bois...
  • Page 56 3. S’assurer que la vis de fixation de la tarière au moteur est bien serrée. Cleveland Iron Works Poêle à grenailles de bois Guide du propriétaire et intructions d’utlisation...
  • Page 57 5. Augmenter la vitesse du ventilateur pour augmenter le taux de combustion. 6. Veuillez communiquer avec le fabricant pour assistance. Guide du propriétaire et intructions d’utlisation Cleveland Iron Works Poêle à grenailles de bois...
  • Page 58 Les tubes de l’échangeur de Nettoyer les tubes de l’échangeur de chaleur. chaleur sont sales. Cleveland Iron Works Poêle à grenailles de bois Guide du propriétaire et intructions d’utlisation...
  • Page 59: Schéma De Câblage

    REMARQUE : SI DES FILS QUELCONQUES DOIVENT ÊTRE REMPLACÉS ILS DEVRONT CORRESPONDRE AUX SPÉCIFICATIONS DE CÂBLAGE ORIGINAL DE TEMPÉRATURE NOMINALE DE 105 °C AVEC ISOLANT DE CLASSE DE 600 V Guide du propriétaire et intructions d’utlisation Cleveland Iron Works Poêle à grenailles de bois...
  • Page 60 Cleveland Iron Works Poêle à grenailles de bois Guide du propriétaire et intructions d’utlisation...
  • Page 61 Guide du propriétaire et intructions d’utlisation Cleveland Iron Works Poêle à grenailles de bois...
  • Page 62: Pièces De Service

    / a Plaque ignifuge 66660 66640 Allumeur 66617 Commutateur de couvercle de trémie 66649 Charnière de porte 66641 Souffleur à combustion 66650 Couvercle Arrière Plaque Fixe Cleveland Iron Works Poêle à grenailles de bois Guide du propriétaire et intructions d’utlisation...
  • Page 63 THIS PAGE INTENTIONALLY LEFT BLANK ESTA PÁGINA INTENCIONALMENTE SE DEJA EN BLANCO CETTE PAGE A ÉTÉ INTENTIONNELLEMENT LAISSÉE VIERGE Guide du propriétaire et intructions d’utlisation Cleveland Iron Works Poêle à grenailles de bois...
  • Page 64 Adresser toute demande de compensation de garantie à : Service Department, Cleveland Ironworks, Inc., 4560 W. 160TH ST., CLEVELAND, OHIO 44135 U.S.A. Indiquez votre nom, adresse et numéro de téléphone, le numéro de modèle et le numéro de série de votre produit et décrivez les détails concernant la demande de compensation. Veuillez également nous indiquer la date d’achat ainsi que les nom et adresse du dépositaire où...

This manual is also suitable for:

Ps60wPsbf66w

Table of Contents

Save PDF