Do you have a question about the PS60W and is the answer not in the manual?
Questions and answers
DENISE HARRISON
February 20, 2025
PROGRAM PRESET RATES, PS130W MULTI FUCNTION CONTROLS
CONFIRM THEY ARE SET
1 comments:
Mr. Anderson
February 20, 2025
To program preset rates on the Cleveland PS60W and PS130W using multi-function controls, follow these steps:
1. Access Preset Configurations: Use the multi-function display to navigate to the preset configuration settings. 2. Select Preset Option: Choose one of the four preset power settings: - P1 (Maximum Power) - P2 (Medium Power) - P3 (Low Power) - P4 (Minimum Power) 3. Adjust Speed Settings: Modify the speeds of the combustion fan and room air circulation fan according to the desired preset. 4. Enable or Disable Preset: Use the preset configuration button to toggle whether a preset is enabled or turn off the feature entirely. 5. Confirm and Save Settings: Finalize the selection to set the stove to operate according to the chosen preset rate.
These settings help control the stove’s temperature output and efficiency.
Page 1
THE AUTHORITY HAVING JURISDICTION (SUCH AS MUNICIPAL BUILDING DEPARTMENT, FIRE DEPARTMENT, FIRE PREVENTION BUREAU, ETC.) SHOULD BE CONSULTED BEFORE INSTALLATION TO DETERMINE ANY NEED TO OBTAIN A PERMIT. OBSERVE ALL LOCAL BUILDING CODES. Cleveland Ironworks a subsidiary of Enerco Group Inc. 4560 West 160th st Cleveland, Ohio 44135 1-800-251-0001...
ADDITIONAL MOBILE HOME REQUIREMENTS ......... 10 OPERATION ..................12 SMART STOVE WIFI CONNECTION ........... 14 WIFI CONTROLS ................15 PS60W, PS130W, AND PSBF66W MULTI FUNCTION CONTROLS ..16 MAINTENANCE .................17 WIRING DIAGRAM ................25 SERVICE PARTS ................26 Cleveland Iron Works Wood Pellet Fire Stove...
Electric Current During Lighting Phase [Amperes] Auger Motor R.P.M. This manual describes the installation and operation of the brand “Cleveland Ironworks” wood pellet fire stove. This stove meets the applicable U.S. Environmental Protection Agency’s emission limits for pellet fired heaters sold after 2020.
For auxiliary information regarding pellet stove safety and operation information contact the National Fire Protection Association (NFPA) by mail at: NFPA, Batterymarch Park, Quincy, MA 02269 or visit the NFPA website: https://www.nfpa.org/ Cleveland Iron Works Wood Pellet Fire Stove Operating Instructions and Owner’s Manual...
• It has at least 13” (330 mm) of clearance from the the specification, this is a sufficient method for each side to the nearest body. protecting the floor area underneath the stove. Cleveland Iron Works Wood Pellet Fire Stove Operating Instructions and Owner’s Manual...
Locate the air intake kit packaged with the stove. See IN YOUR AREA. Figure 4. Take measurements of your space and plan for the installation of horizontal venting to the outside Cleveland Iron Works Wood Pellet Fire Stove Operating Instructions and Owner’s Manual...
Page 7
THEN THE STOVE MUST BE INSTALLED SUCH THAT PARTS & MATERIALS REQUIRED (NOT SUPPLIED) IT IS ATTACHED TO THE STRUCTURE. • Floor Protection (see “FLOORING SPACE” and “FLOORING MATERIAL” on page 5) Cleveland Iron Works Wood Pellet Fire Stove Operating Instructions and Owner’s Manual...
Page 8
Type HT chimneys in the Standard ONLY APPROVED CANADIAN WALL PASS for Chimneys, Factory-Built, Residential Type and THROUGH Building Heating Appliance, UL 103. • A International Conference of Building Officials Cleveland Iron Works Wood Pellet Fire Stove Operating Instructions and Owner’s Manual...
Page 9
24 gauge thickness. Fasteners used to secure chimney section shall not penetrate chimney flue liner. Cleveland Iron Works Wood Pellet Fire Stove Operating Instructions and Owner’s Manual...
• The stove must be provided a permanently ducted source of outside air to support combustion which meets the following requirements: — The duct must be made of metal exclusively, not other materials such as plastic. Cleveland Iron Works Wood Pellet Fire Stove Operating Instructions and Owner’s Manual...
Page 11
Do not mix brands of components for the same ventilation system. The following figures illustrate various methods and requirements of using a manufactured chimney and connection pipes to vent the stove. Cleveland Iron Works Wood Pellet Fire Stove Operating Instructions and Owner’s Manual...
• The pellets should be less then 30mm long, with a diameter between 5 and 6.5 mm. • Do not use the pellet sediment & debris at the Cleveland Iron Works Wood Pellet Fire Stove Operating Instructions and Owner’s Manual...
Page 13
3. • Cleaning Cycle: The firepot draws dust, ash, & MINIMIZING CREOSOTE FORMATION Cleveland Iron Works Wood Pellet Fire Stove Operating Instructions and Owner’s Manual...
Smart Stove app. connection option on the “Devices” tab at the Cleveland Iron Works Wood Pellet Fire Stove Operating Instructions and Owner’s Manual...
PS60W, PS130W, AND PSBF66W MULTI FUNCTION CONTROLS Manual / Automatic Wireless Connection Confirm Rate Select Notification Light Notification Light Up Selector MULTI FUNCTION DISPLAY Display Screen Settings Time Down Selector Power Figure 18a Mounted Multi Function Controls Panel Press to cycle between temperature reports...
Figure 20 Outlet Duct Cleveland Iron Works Wood Pellet Fire Stove Operating Instructions and Owner’s Manual...
Page 18
See pages 27 through 29. year to determine if cleaning is necessary. During start up, shut down, and erroneous operation of the stove incomplete combustion can produce ash, soot, and Cleveland Iron Works Wood Pellet Fire Stove Operating Instructions and Owner’s Manual...
Page 19
Pull the hot surface igniter free, and install replacement service part. See Figure 23 and 25. Figure 23 Igniter Disassembly REPLACING: AUGER SYSTEM Cleveland Iron Works Wood Pellet Fire Stove Operating Instructions and Owner’s Manual...
Page 20
If a low pressure is created in the firebox by a leak, stove. opening the door to the firebox, a blocked flue, or • To remove the PS60W side panels, remove the an unsealed ash drawer then the switch will shut scews securing it on the rear of the heater. Then the stove off as a precaution.
Page 21
1. Check wires and connection points. ESO1 Open circuit at temperature sensor #1. 2. Replace Motherboard. 1. Check wires and connection points. ESC2 Short circuit at temperature sensor #2. 2. Replace Motherboard. Cleveland Iron Works Wood Pellet Fire Stove Operating Instructions and Owner’s Manual...
Page 22
2. Check that the auger is not blocked. If it is blocked, jammed, or pellets. remove the cause of the jamming. disconnected. 3. Check that the auger screw fastening the auger to the motor is secure. Cleveland Iron Works Wood Pellet Fire Stove Operating Instructions and Owner’s Manual...
Page 23
4. Increase the cross sectional area of the ducting. 5. Increase the fan’s speed to increase the rate of combustion. 6. Contact the manufacturer for assistance. Cleveland Iron Works Wood Pellet Fire Stove Operating Instructions and Owner’s Manual...
Page 24
Heat exchange tubes or flue pass is Clean the heat exchanger tubes or flue pass. dirty. Cleveland Iron Works Wood Pellet Fire Stove Operating Instructions and Owner’s Manual...
NOTE: IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 105 °C AND RATED FOR 600V Cleveland Iron Works Wood Pellet Fire Stove Operating Instructions and Owner’s Manual...
Page 26
Cleveland Iron Works Wood Pellet Fire Stove Operating Instructions and Owner’s Manual...
Page 27
Cleveland Iron Works Wood Pellet Fire Stove Operating Instructions and Owner’s Manual...
66638 Fire Pot Fireproof Plate 66658 Remote (not shown) 66639 Vacuum Switch 66649 Door Hinge 66659 Accessory Kit 66640 Igniter 66650 Rear Cover Fixed Plate 66660 Auger Assembly Cleveland Iron Works Wood Pellet Fire Stove Operating Instructions and Owner’s Manual...
Page 29
This Warranty gives you specific legal rights, and you may have other rights which vary from state to state. Cleveland Ironworks Inc. reserves the right to make changes at any time, without notice or obligation, in colors, specifications, accessories, materials and models.
Need help?
Do you have a question about the PS60W and is the answer not in the manual?
Questions and answers
PROGRAM PRESET RATES, PS130W MULTI FUCNTION CONTROLS CONFIRM THEY ARE SET
To program preset rates on the Cleveland PS60W and PS130W using multi-function controls, follow these steps:
1. Access Preset Configurations: Use the multi-function display to navigate to the preset configuration settings.
2. Select Preset Option: Choose one of the four preset power settings:
- P1 (Maximum Power)
- P2 (Medium Power)
- P3 (Low Power)
- P4 (Minimum Power)
3. Adjust Speed Settings: Modify the speeds of the combustion fan and room air circulation fan according to the desired preset.
4. Enable or Disable Preset: Use the preset configuration button to toggle whether a preset is enabled or turn off the feature entirely.
5. Confirm and Save Settings: Finalize the selection to set the stove to operate according to the chosen preset rate.
These settings help control the stove’s temperature output and efficiency.
This answer is automatically generated