Panasonic KX-TGCA20EX Service Manual page 43

Telephone equipment
Table of Contents

Advertisement

Items
(F)*
Battery Monitor Check
(G)
Battery Low
Confirmation
(H)* BBIC Clock Adjustment
(I)*
Transmitted Power
Confirmation
(J)*
Modulation Check and
Adjustment
(K)*
Frequency Offset
Confirmation
(L)*
Sensitivity Receiver
Confirmation
(M)*
Power RAMP
Confirmation
Check
Point
-
1. Apply 2.25 V between BATT+ and BATT-.
2. Execute the command
sendchar PAD
sendchar LED 0
sendchar CRX 0 1
sendchar AD1
It assumes that the return value is XX.
a) XX: 70: No need to adjust
b) XX: 66 ~ 6F: Need to adjust
XX: 71 ~ 7A: Need to adjust
Write AD value of 2.25 V to EEPROM.
ex) read data: XX = 6A, write data: YY = 6A
read data: XX = 73, write data: YY = 73
EEPROM = 0009(Low Voltage) write "YY"
Execute the command "wreeprom 00 09 01 YY".
EEPROM = 000A(No Voltage) write "YY -C"
Execute the command "wreeprom 00 0A 01 ZZ".
Note:
ZZ = YY - C
c) XX: 00 ~ 65: Reject
XX: 7B ~ FF: Reject
-
1. Apply 2.40 V between BATT+ and BATT-.
2. Confirm that there is no flashing of Battery Icon.
3. Apply 2.25 V ± 0.08 V between BATT+ and BATT-.
4. Confirm that there is flashing of Battery Icon.
CKM
1. Apply 2.6 V between BATT+ and BATT- with DC power.
2. Input Command "sendchar sfr", then you can confirm the current value.
3. Check X'tal Frequency. (10.368 MHz ± 100 Hz).
4. If the frequency is not 10.368 MHz ± 100 Hz, adjust the frequency of CKM
executing the command "sendchar sfr xx xx (where xx is the value)" so that the
reading of the frequency counter is 10.368000 MHz ± 5 Hz.
Note:
Clear the registered information for Base Unit before measurement, because the
Frequency will not possibly get stable due to the registered information.
Pressing the button of "3" "5" "7" "#"clears the registration.
Register to it on Base Unit after measurement.
-
Short Antenna pattern to GND.
1. Configure the DECT tester (CMD60) as follows;
<Setting>
• Test mode: PP
• RFPI: 0102030405
• Traffic Carrier: 5
• Traffic Slot: 4
• Mode: Loopback
• RF LEVEL = -70 dBm
• PACKET: PP32Z
2. Execute the command "sendchar TST 01 02 03 04 05".
3. Initiate connection from DECT tester.
4. Confirm that the NTP value at ANT is 19 dBm ~ 25 dBm.
-
Follow steps 1 to 3 of (I).
4.Confirm that the B-Field Modulation is -350 ± 50/+350 ± 50 kHz/div using data
type Fig 31.
-
Follow steps 1 to 3 of (I).
4.Confirm that the frequency Offset is < ± 20 kHz.
-
Follow steps 1 to 3 of (I).
4.Set DECT tester power to -88 dBm.
5.Confirm that the BER is < 1000 ppm.
-
Follow steps 1 to 3 of (I).
4.Confirm that Power RAMP is matching.
KX-TGC210/KX-TGC212/KX-TGC213/KX-TGC220/KX-TGC222/KX-TGCA20
Procedure
43
Check or
Replace Parts
IC1, R45
IC1, R45
IC1, X1, C47
IC1, C801,
C859, C860,
C861, C862
Refer to (I)
Refer to (I)
Refer to (I)
Refer to (I)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents