VCTp Software Updating, I2C (continued)
LC-32GA5E
LC-37P55E
4. Check installation LPT driver using "C:\Program Files\Micronas\LptDrv\LptDrvTest.exe". After run this software, if
LPT driver is installed properly must appear this screen:
����� ��� ���� ��������� �� ��� ������ �� ��������� �������� ���� ������ ���� �������
 �� ��� ������ �� ��� ��� ����� ������ �� ����� �������� ���� ��������
•If the result is not OK, check inside PC bios: Parallel Port Mode=EPP
To run VCTp software update program, please click over "VCTP" icon from "START\All programs\Micronas\Visual
I2C\IC\VCTP" and after Visual I2C finish their starting process click on "TVT" module. As additional method, it's pos-
sible to create a direct access to "C:\Program Files\Micronas\Visual I2C\ic\vct6wxyP\vctq_tvt.vi2c" and launch it from
Windows Desktop.
��������������������� ������������������������������ ��� ������ �� ���� ������� ��������
To start updating process follow next instructions:
1. Set Autoread in ON option.
2. Click on "GO" button.
3. Wait until "40" appears in Bootloader Version field.
4. Close DOS pop up windows pressing any key ("Press any key to continue...".).
5. Click on the "Erase flash" button and wait for a seconds and set the AutoRead to OFF.
6. Check in the desired software version is selected in the "Load BinàFlash" option. If it's not the correct one,
please double click on the file name and select it. The first time this software is use it's necessary to confirm write
Addressing margin as from 0x0 to 0x7ffff.