OPERATOR’S MANUAL TABLE OF CONTENTS GENERAL WARNINGS ........................4 1.1. SYMBOLS............................4 1.2. INTENDED USE ..........................5 1.2.1. CLASSIFICATION ........................... 5 1.2.2. ENVIRONMENTAL CONDITIONS ....................5 1.2.3. WARRANTY ............................ 5 1.3. SAFETY WARNINGS ........................6 1.4. DISPOSAL AT THE END OF LIFE ....................6 1.5.
Read this manual thoroughly before using the device. • The devices described in this manual are manufactured by CEFLA s.c. - via Selice Provinciale 23/A - 40026 Imola (BO) Italy, a manufacturer complying with the European Directive on medical devices.
• PHOTOBIOLOGICAL SAFETY classification. • Classification of the equipment in accordance with standards EN 62471:2008 and IEC 62471:2006: - VENUS PLUS -L version / VENUS PLUS CL -L version / VENUS PLUS CL MCT version / VENUS PLUS E version: Risk group 1. 1.2.2. ENVIRONMENTAL CONDITIONS The equipment is to be installed in rooms that satisfy the following requirements: •...
OPERATOR’S MANUAL 1.3. SAFETY WARNINGS WARNING! • Equipment installation, expansion and technical support must be performed EXCLUSIVELY by personnel authorised by the manufacturer to carry out these operations. • The dental light must be installed on a specific control and power supply device, such as a dental unit, or with an electric system that complies with the standard IEC 60364-7-710;V2 (i.e. the regulations concerning the electric systems to be used in surgeries) or equivalent standards in force in the country where the equipment is installed.
Transparent screen. c) Removable handles suitable for cold sterilization. d) ON switch. e) Brightness adjustment knob. VENUS PLUS -L version, VENUS PLUS CL -L version light body: a) Light source consisting of 2 multichip LEDs. c) Removable handles sterilizable inside autoclave.
PLUS MCT version, VENUS E version lights for installation on dental unit: f) Self-balancing arm. VENUS PLUS CL version, VENUS PLUS CL -L version, VENUS PLUS CL MCT version for ceiling installation: f) Self-balancing arm. i) Flange for ceiling installation.
NOTE for CL version: the light is powered by the main switch mounted at the time of installation. • To turn light off, move switch (d) up again. VENUS PLUS -L version, VENUS PLUS CL -L version lights: • To turn light on, move switch (d) up.
OPERATOR’S MANUAL VENUS lights, E version: • To turn the light on and off, operate the switch (d) or sweep in the sensitivity field (5 cm) of the sensor (k). ON/OFF ON / OFF NOTE: if the light does not turn on or off when sweeping your hand rapidly across the sensor, sweep it across again more slowly. 3.2. BRIGHTNESS ADJUSTMENT Turn the knob (e): • Clockwise: increases brightness.
OPERATOR’S MANUAL 3.3. CHANGING OPERATING MODE AND COLOUR TEMPERATURE (VENUS PLUS MCT version and VENUS PLUS CL MCT version lights only) By briefly pressing on one of the two buttons on the head unit handles, it is possible to choose between two operating modes of the light: • Standard •...
NOTE: Without the handle, the light is no longer balanced and the optical unit will tend to move upwards. VENUS PLUS -L version, VENUS PLUS CL -L version, VENUS PLUS MCT version, VENUS PLUS CL MCT version, VENUS E version...
Do not use sponges or, in any case, any material that can be reused. • Light arms and optical unit cover. Clean the outer parts of the equipment using STER 1 PLUS (CEFLA S.C.) or a similar product. • Transparent screen and reflector.
OPERATOR’S MANUAL MAINTENANCE REMOVING THE TRANSPARENT SCREEN VENUS PLUS, VENUS PLUS CL version lights only. WARNING! Carry out this operation with the light off and after it has cooled down. To remove the transparent screen proceed as follows: • remove the handles (see paragraph 3.4.);...
OPERATOR’S MANUAL 5.2. REPLACING THE BULB VENUS PLUS, VENUS PLUS CL version lights only. WARNING! Carry out this operation after having cut the power to the device to which the lamp is connected and only after it has cooled down.
• Light source: 2 multichip LEDs. • Maximum temperature on accessible surfaces (during normal use): < 50°C. • Total weight: 5.5 kg. VENUS PLUS CL -L version model lights: • Continuous operation. • Power supply voltage: 100/115/230 V~ 50/60 Hz. • Power absorbed: 18 VA.
Page 17
• Light source: 6 power LEDs. • Maximum temperature on accessible surfaces (during normal use): < 50°C. • Total weight: 5.5 kg. VENUS PLUS CL MCT version model lights: • Continuous operation. • Power supply voltage: 100/115/230 V~ 50/60Hz. • Power absorbed: 18 VA.
• Brightness does not change when acting on the proper knob. Call Technical Service. VENUS PLUS -L version, VENUS PLUS CL -L version, VENUS PLUS MCT version, VENUS PLUS CL MCT version, VENUS E version model lights: • The lamp cannot be turned on with the proper knob or NO TOUCH sensor (if available).
OPERATOR’S MANUAL TECHNICAL SERVICE For any technical intervention request on the product, whether under warranty or out of warranty, please contact the TECHNICAL SERVICE of the dealer or retailer who supplied the product.