Mitsubishi Heavy Industries SRK63ZR-WF Technical Manual page 25

Inverter wall mounted type residential air-conditioners
Hide thumbs Also See for SRK63ZR-WF:
Table of Contents

Advertisement

(2) Correction of cooling and heating capacity in relation to one way length of refrigerant piping
Piping length [m]
Cooling
Heating
(3) Correction relative to frosting on outdoor heat exchanger during heating
Air inlet temperature of
outdoor unit in °C WB
Adjustment coefficient
How to obtain the cooling and heating capacity
7
10
15
1.0
0.99
0.975
1.0
1.0
1.0
-15
-10
-9
0.95
0.95
0.94
SRK63ZR-WF
6.3
SRK63ZR-WF
24
-
20
25
0.965
0.95
1.0
1.0
-7
-5
-3
0.93
0.91
0.88
6.1k
-
'09•SRK-DB-087D
'22 • SRK-T-362
30
0.935
1.0
-1
1
3
5 or more
0.86
0.87
0.92
1.00