Parameter Adjustment - S4A ED100 Quick Start Manual

Intelligent automatic flat door system
Table of Contents

Advertisement

Parameter adjustment

Electric lock +
Emergency power supply +
COM
Double door interlock (in)
COM
Double door interlock (out)
Double door synchronization (in)
COM
Double door synchronization (out)
1. Remote learning button
2. Opening speed
3. Buffer angle of opening door
4. Closing speed
5. Buffer angle of closing door
6. Hold open time
7. Reserved function key
Switch setting (K) : After setting, power off, restart is effective
K1: When the power is turned on, in the initial state, the door moves to the correct position in the direction of closing
the door, and if it moves in the direction of opening the door, the switch position is changed.
K2: When the double door is synchronized, the active door is placed and the driven door is placed (on)
K3: Choose PUSH arm or PULL arm
K4: The door is opened and the forbidden force is placed (on)
Remote learning button
K1 Opening direction selection
Opening speed
K2 Master driven door selection
Door opening angle
K3 Choose PUSH arm or PULL arm
Closing speed
K4 Tightness selection
Closing buffer angle
Hold open time
Reserved function
Clockwise speed is getting faster
Increased clockwise angle
Clockwise speed is getting faster
Increased clockwise angle
Time is longer in clockwise direction
About 21 seconds in 3/4 position
Sensor power supply
Sensor power supply
Sensor signal
Sensor signal
+12V
0V
COM
Open. the door for
collision/ start
Crashproof when
closing the door
Entrance guard signal
About 7 seconds at 1/4 position
About 14 seconds in 1/2 position