Master Station Quick Start Guide
The ViLX-TMS3-W-8/0 master station/ViLX-ACM3-8 Assist Call master is part of the Lexicomm
Network EVC system suitable for medium to large applications up to 512 lines. It is
compatible with Vox Ignis range of Type A, Type B, Type C outstations and the Assist Call
range of emergency assistance alarms.
This guide summarises applicable information from the full
manual, which is available from the Vox-Ignis website by
scanning this QR code. The installation and commissioning
manual and the User Guide are contained on the micro SD card
that is fitted to the rear of the ViLX-TMS3-W-8/0 master
station display PCB.
Figure 1

1. Important Safety Information

This Equipment must only be installed and maintained by a suitably skilled and competent
person.
This Equipment is defined as Class 1 in EN IEC62368-1:2020+A11:2020 (Low Voltage
Directive) and must be EARTHED.
Caution
Indoor Use Only
Shock Hazard-
Warning
Isolate Before Opening
TO REDUCE THE RISK OF FIRE OR
Warning
ELECTRIC SHOCK, DO NOT EXPOSE THIS
UNIT TO RAIN OR MOISTURE
Warning
THIS UNIT MUST BE EARTHED
Warning
NO USER SERVICEABLE PARTS
Figure 2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TMS3 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Lexicomm TMS3

  • Page 1 Lexicomm Network TMS3 EVCS Master Station Quick Start Guide The ViLX-TMS3-W-8/0 master station/ViLX-ACM3-8 Assist Call master is part of the Lexicomm Network EVC system suitable for medium to large applications up to 512 lines. It is compatible with Vox Ignis range of Type A, Type B, Type C outstations and the Assist Call range of emergency assistance alarms.
  • Page 2 Each ViLX-TMS3-W-8/0 Master Station requires local isolation with verification as per the Electricity at Work Regulations 1989, returning to a B6A breaker clearly marked “EMERGENCY VOICE COMMUNICATION SYSTEM. DO NOT TURN OFF”. 2. Anti-static handling guidelines Make sure that electrostatic handling precautions are taken immediately before handling PCBs and other static sensitive components.
  • Page 3 The ViLX-TMS3-W-8/0 Master Station weighs 6kg with batteries, so care should be taken to securely mount the Station on stud walling. Network address EVC connection Mains supply Figure 4 Lines Lines Mains Earth Relay Block contacts Dual Line Card Dual Line Card...
  • Page 4 5.3 Network Address The TMS3 master station factory default network address is 1, network address 2 is the default address for a system expander panel. When additional panels are added to the network, the next address will be address 3. It is not essential that network addresses run sequentially, and a gap can be left in the address sequence, however this is less desirable and makes fault finding more difficult.
  • Page 5 Figure 6 6.3 Power Up Power up the ViLX-TMS3 Master Station using mains only, fed via a double pole isolator local to the panel fed from a dedicated circuit. The AC power indicator will be illuminated, and the DC power indicator is extinguished. The PSU fault and General fault indicators will be illuminated.
  • Page 6 7. Settings Menu For a full description of the menus and features of the TMS3 master station, the full installation and commission manual should be consulted. All menus are accessed from the home screen as shown in Figure 7.
  • Page 7 The panel settings screen is shown by pressing the icon on the settings screen. At the top of the screen is the address and name of the panel that is being configured. This panel can be changed by pressing the icons.
  • Page 8 8. Operational Flowcharts 8.1 TMS Home/Menu Structure 8.2 TMS Settings Structure 9. What’s included Remove the ViLX-TMS3 from its packing, and check the contents against the following list: • ViLX-TMS3 Master Station. • Quick Start Guide. • Accessory pack with the following contents:- 1 ×...

This manual is also suitable for:

Vilx-tms3-w-8/0

Table of Contents