Download Print this page

Power-On Commissioning; Troubleshooting - Huawei MERC-1300W-P Quick Manual

Smart pv optimizer
Hide thumbs Also See for MERC-1300W-P:

Advertisement

4

Power-On Commissioning

1. The physical layout of the optimizers must be provided so that you can easily
locate faulty optimizers based on the physical layout diagram.
2. The physical layout of the optimizers must be provided to use the optimizer
disconnection detection function. After optimizer disconnection detection is
performed, the locating result can be viewed on the Layout screen.
3. Choose Maintenance > Subdevice management > Auto search to add an
optimizer. For details about the physical layout of optimizers, see the
Smart PV Optimizer User Manual
scan the QR code to obtain the
If changes occur in the system, such as adding, deleting, and replacing an optimizer, adjusting
the physical position of an optimizer, or adjusting the PV string connected to the solar inverter
input, turn off the DC and AC switches of the inverter and wait for 5 minutes before performing
the operation to avoid personal injuries. After the change is performed, the optimizer search
process must be performed again and the physical layout diagram must be updated. Otherwise,
the networking is incomplete, optimizer faults cannot be located, or the system fails.
5

Troubleshooting

1. Open the FusionSolar app, log in to intl.fusionsolar.huawei.com using the installer account,
choose Me > Device commissioning, and connect to the WLAN hotspot of the solar inverter.
2. Select installer and enter the login password. Tap Log In. The device commissioning screen is
displayed.
3. Choose Device monitoring, select the PV string and check the optimizer status.
Status Description
Green
The optimizer is running properly.
The optimizer is offline. Check that the SN and
Gray
location information are correct and search for the
device again.
Red
The optimizer is faulty.
Yellow The optimizer is disconnected.
FusionSolar App Quick Guide
or
FusionSolar App Quick Guide
8
MERC
. You can
.
Optimizer status

Advertisement

loading