Repair; Battery; Disassembling; Motor And Pump Section - Makita DMP180 Repair Manual

Cordless inflator
Hide thumbs Also See for DMP180:
Table of Contents

Advertisement

4

REPAIR

4-1

Battery

4-1-1

Disassembling

1
Remove the battery.
4-2

Motor and Pump section

4-2-1
Disassembling
[1]
[3]
Fig.1
[1]
[2]
Fig.2
[2]
Fig.3
[6]
[1]
[2]
[5]
[4]
1
Remove Swim ring adapter [1] and Ball adapter [2]
from Fixed bracket.
2
Remove Screws 3x14 [1] (10 pcs), then remove
Housing.
3
Remove Mats [2] (2 pcs).
4
Remove Lead wires of Motor assembly [1] to
release the lock by pinching the claw on the
connector of PCB [2].
5
Loosen the screw on Clamp [3] with a slotted
screwdriver [4], then remove Tube on the side of
Pressure sensor [5] with 1R311, and then pull out
Tube. Remove Fixed bracket [6].
6
Remove Motor assembly [1] from Housing.
Note that Rubber (Cylinder) may come off (be left on
Housing side) when Motor assembly [1] is removed
from Housing.
4 / 9
Note

Advertisement

Table of Contents
loading