Specifications

For complete technical specifications, see the technical datasheet: 
etcconnect.com/Products/High-End-Systems/Lighting-Fixtures/SolaFrame/Studio/Documentation.aspx.

Environment

• Ambient operating temperature range: -10°C to 35°C (14°F to 95°F).
• Relative humidity: 0%–90%, non-condensing.
• Storage temperature: -20°C to 60°C (-4°F to 140°F).
• Indoor use only.
• Dry locations only, IP20 rated.

Power

WARNING:
to avoid damage to the fixture's internal power supply and other electrical
components. Using a dimmable power source can damage the fixture and
will void the warranty.

Electrical

• 100–240 VAC at 50/60 Hz
• Maximum power consumption: 629 W; with Defogger 667 W

Input and Power Factor

The values listed below were measured with the fixture in Standard mode with LEDs at full and
all motors functioning.
VAC
Amps
100
6.3
120
5.2
200
3.0
208
2.9
220
2.8
230
2.7
240
2.5
CAUTION:
breaker to trip. Ensure that the circuit can handle the fixture's maximum
potential draw before you connect it.
Specifications
Connect the fixture to a non-dimmable power source in order
Hz
Watts
50
629
60
614
50
588
60
587
50
586
50
592
60
585
Using this fixture below 100 V on a 15 A breaker may cause the
VA
PF
628
0.99
619
0.99
610
0.97
604
0.97
613
0.96
615
0.96
607
0.96