Fitted Within A Suspended/False Ceiling - Space-Ray 600 Installation Manual

Electric radiant heat panel
Table of Contents

Advertisement

Fig. F
Fig. G
Fig. H
Fig. J
Models
600
900
1200
Table 3 - Ceiling mount hole centres
6
A
B
C
595
595
82
595
895
82
595
1195
82
Fig. J
Fig. K

4.1.3 Fitted within a suspended/false ceiling

Always isolate the heater from the mains supply when
mounting or adjusting the heater position.
The heat panels are suitable for mounting in false/
suspended ceilings as the dimensions are the
same as standard ceiling tiles.
The heater must be positioned with respect to the
minimum clearances shown in Fig. D.
1. Ensure that the ceiling grid frame is suitablly sized
to accommodate the heater.
2. Check the ceiling grid frame to ensure there is no
damage and that it is flat.
3. Ensure that the return edge (on which the heater
will sit) sufficiently covers all sides of the heater
panel when it lays within the frame see Fig. L.
4. Check that the ceiling frame has sufficent supports
to accomodate the weight of the panel heater, es-
pecially if more than one heater is to be installed.
5. Ensure the heater is seated fully in the frame
without any gaps to maintain the fire rating of the
ceiling.
6. Ensure the mains supply cord does not rest on the
heater.
D
432
732
1032
CAUTION

Advertisement