Page 1
MA-15 AIRPURIFIER READ AND SAVE THESE INSTRUCTIONS INSTRUCTION MANUAL AND WARRANTY INFORMATION Lifetime war ranty if filters are r eplaced on time MA-15-SMART Rev: 11/16/21...
IMPORTANT SAFETY INSTRUCTIONS: IN ORDER TO AVOID ANY DAMAGE TO YOU, OTHERS OR PROPERTY, FOLLOW THE FOLLOWING SAFETY PRECAUTIONS: IF THE POWER CORD OR UNIT DOES NOT WORK, CONTACT MEDIFY CUSTOMER SERVICE IMMEDIATELY. READ ALL INSTRUCTIONS BEFORE USING. WARNING – TO REDUCE THE RISK OF BURNS, FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS •...
Page 3
• Do not use the air purifier in the room with fumigation type pesticides. Chemical residue could be accumulated inside the machine and then released causing harm. The room should keep ventilated thoroughly after you use insecticide and then start to use air purifier. •...
• Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock or fire, or damage the air purifier. • Do not block air intakes or exhaust in any manner. Do not use on any soft surface, like a bed, where openings may become blocked.
Page 5
SUGGESTED ROOM SIZE Up to 165 sf every 15 min and up to 330 sf every 30 min. Portable air purifiers will be more effective in rooms where all the doors and windows are closed. AIR CHANGES PER HOUR This air purifier will purify the air up to 165 sf every 15 min and up to 330 sf every 30 min (assuming an 8 FT/2.43 M ceiling)one time per hour on high speed in a closed room.
CONTROL PANEL HOW TO USE BEFORE TURNING THE UNIT ON • Take the air purifier out of the box and remove the clear protective plastic bag. • Place the air purifier on a firm, level surface. • Plug the power cord into a standard AC outlet. POWER BUTTON AND FAN SPEED SETTINGS •...
Page 7
4. Tap “+” in the upper right corner to add a device. 5. Select "Air Purifier" 6. Choose “Medify Air” 7. Ensure that Bluetooth, Camera, and Location of the mobile device are enabled 8. the next page will jump out of two network configuration mode, one is to scan the QR code...
Page 8
9. If scanning QR code is selected for network configuration, please follow the following steps. Long press child-lock + SPEED button of the purifier for 3S. After hearing a "drip" sound, restart the • machine and enter the mode of scanning QR code for network configuration, and the WIFI icon will turn into a red light flashing.
Page 9
10. If you choose not to scan the QR code for network configuration, please follow the following steps. • Long press ON/OFF+UV key 3S, hear the sound of "drip", restart after entering the non-scanning QR code network mode, WIFI icon will turn green flashing. •...
Page 10
11. After the WIFI configuration of the purifier is successful • Enter the device interface of APP Select the air purifier device that has been added. • • Enter the APP control interface of the air purifier, and the air purifier can be controlled through the mobile APP.
Page 11
HOW TO CONFIGURE NOTIFICATION AND SMART REORDER SETTINGS Smart Reorder helps track your filter purchases from Amazon.com, so that the device can notify you or re-order filter for you when your inventory runs low. To use smart reorder, please complete the following: •...
2. Take away the grilles from the unit. To purchase genuine Medify replacement True HEPA H13 filters, model MA-15, go back to your retailer where you purhased your air purifier, or visit www.medifyair.com.
Page 13
6. Plug the power cord into a standard AC outlet. Press and hold the Timer+UV button for 3 seconds to reset the indicator. To purchase genuine Medify replacement True HEPA H13 filters, model MA-15, go back to your retailer where you purhased your air purifier, or visit www.medifyair.com.
CLEANING AND MAINTENANCE CLEANING THE PRE-FILTER NOTE: For best performance, vacuum the pre-filter once a month under normal usage. 1. Unplug the air purifier. Remove the True HEPA H13 filter as described in the Replacing the True HEPA H13 Filter section. Vacuum the white side of the True HEPA H13 filter using the brush attachment of your vacuum cleaner, cleaning it thoroughly.
This product earned the ENERGY STAR by meeting strict energy efficiency guidelines set by the US EPA. US EPA does not endorse any manufacturer claims of healthier indoor air from the use of this product. The energy efficiency of this ENERGY STAR qualified model is measured based on a ratio between the model’s CADR for dust and the electrical energy it consumes, or CADR/Watt.
If you have any additional questions, please contact customer service. All names and trademarks are property of Medify Air. Our company reserves the right to change the product at any time, without prior notice, and the company has no obligation to adjust any products supplied earlier.
Page 17
Medify Air replacement filters at least once every four (4) months or after 2,000 hours of use. Within the first 30 days, Medify Air will replace the defective unit at no charge to you and reimburse you for any shipping charges. After 30 days, Medify Air’s obligation and liability under this Lifetime Warranty is dependent on your use of our genuine filters, purchased on our website or from our authorized resellers, which can be found on our website.