Page 1
MA-112 AIRPURIFIER READ AND SAVE THESE INSTRUCTIONS INSTRUCTION MANUAL AND WARRANTY INFORMATION Lifetime warranty if replacing filters on time MA-112...
IMPORTANT SAFETY INSTRUCTIONS: IN ORDER TO AVOID ANY DAMAGE TO YOU, OTHERS OR PROPERTY, FOLLOW THE FOLLOWING SAFETY PRECAUTIONS: IF THE POWER CORD OR UNIT DOES NOT WORK, CONTACT MEDIFY CUSTOMER SERVICE IMMEDIATELY. READ ALL INSTRUCTIONS BEFORE USING. WARNING – TO REDUCE THE RISK OF BURNS, FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS •...
Page 3
UNIQUE FEATURES & SPECIFICATIONS FOUR-STEP FILTER PURIFICATION SYSTEM FIRST STEP: PRE FILTER Removes large particles such as: Dust, Dander, Hair and others SECOND STEP: TRUE HEPA H13 FILTER HEPA H13 is a higher grade of TRUE HEPA that can remove 99.9% of particles down to 0.1 microns as well as PM2.5 particles such as smoke, pollen, dust mites and others.
Page 4
TECHNICAL DATA • Voltage: 220-240V AC SOHz • Rated power: 120W • Noise level: < 69 dB(A) • Unit dimensions: 28.311 H x 15.711W x 15.411 D • Unit weight: 32.8 lbs. AIR OUTLET COVER HANDLE SENSOR COVER CONTROL PANEL INDICATOR LIGHT OF AIR QUALITY FRONT PANEL BACK COVER...
BEFORE USE LEARNING ABOUT AIR QUALITY INDICATOR LIGHT The air quality indicator reflects the current air quality INDICATOR LIGHT OF AIR QUALITY condition. Air Quality Indicator Light Index Blue / Excellent Green / Average Red / Poor DISASSEMBLY AND INSTALLATION METHODS OF SIDE COVERS 1.
Page 6
INSTALLING THE AIR PURIFIER Do not obstruct the air intake or the clean air outlet. 50cm To ensure enough ventilation, make sure there is a 20 inch (or 50 cm) distance between the air inlet and the wall or 50cm nearby furniture.
Page 7
3. Do not disassemble the filters. Filters sets come in one piece for maximum efficiency. 4. Remove any exterior packaging of the filter sets. Place the filters back in the air purifiers once the packaging has been removed. 5. To reinstall the side covers, align the fixed slots and insert the covers into the slots.
IONIZER MODE Press the Ionizer button . The unit will beep and the indicator light of the Ionizer will be on. Press the Ionizer button again and the unit will leave the Ionizer mode. The indicator light for the Ionizer will be off. When the filter replacement indicator is on, the user needs to replace the filter and press the Ionizer button for 3 seconds to reset it.
Page 10
2. Disassemble the cover of the air quality sensor. 3. Use a dry swab to clean the air quality sensor, air intake and air outlet. Use a hair dryer to blow out the sensor area or use a vacuum cleaner. Either works well to clean the sensor.
FILTER REPLACEMENT LIGHT INDICATOR TO REPLACE THE FILTER The indicator light will remind users when it is time to change your filter. 1. Remove all existing filters from the unit. Remove all packaging from new filter sets. Then, install the new filters into the unit in the same order as existing filters.
(6) months of after 3,000 hours of use. The filter replacement indicator will let you know when it is time to replace it. Medify Air will replace the defective unit at no charge to you and reimburse you for any shipping charges.
Need help?
Do you have a question about the MA-112 and is the answer not in the manual?
Questions and answers