Olsberg HKI Leo 28/9251 Instructions Manual page 23

Table of Contents

Advertisement

Available languages

Available languages

Produktdatenblatt
Stove product data sheet
Technical Documentation according to Regulation (EU) 2015/1185 for solid fuel local space heaters (with additional parameter of Technical Documentation according to Regulation (EU)2015/1186)
Model identifier
Manufacturer| Adress
Test reports
Test laboratory
Harmonized Standards
Other technical standards and specifications
Indirect heating function [yes / no]
Direct heat output
Indirect heat output
1
Characteristics when operating with the preferred fuel
Seasonal space heating energy efficiency ηs [%]:
Energy efficiency index (EEI):
Energy efficiency class
Fuel
Wood logs, moisture content ≤ 25 %
Compressed wood, moisture content < 12 %
Lignite briquettes
Other fuels
5
Specification
nominal heat output
minimum heat output (partial load heat output according to standard)
Auxiliary power consumption at nominal heat output
Auxiliary power consumption at minimum heat output
Auxiliary power consumption in standby mode
Permanent pilot flame power requirement (if applicable)
Specific precautions for assembly, installation or maintenance
Fuel efficiency at nominal heat output (Based on the net calorific value (NCV)
Fuel efficiency at minimum heat output (Based on the net calorific value (NCV)
Type of heat output/room temperature control (select one):
Single-stage heat output, no room temperature control
two or more manual stages, no room temperature control
with mechanic thermostat room tem-perature control
with electronic room temperature con-trol
with electronic room temperature con-trol plus day timer
with electronic room temperature con-trol plus week timer
Other control options (multiple selection possible)
room temperature control, with pres-ence detection
room temperature control, with open window detection
with distance control option
1
No entry is made for fireplaces without water-bearing components.
Values for the annual efficiency and emissions are to be given here for the preferred fuel.
2
Values for annual fuel efficiency and emissions are to be given here for all other, other suitable fuels.
3
Corresponds to the partial load heat output according to EN 16510
4
Wood-like biomass, non-wood-like biomass, anthracite and dry steam coal, hard coal coke, low-temperature coke, bituminous coal, peat briquettes, briquettes made
5
from a mixture of fossil fuels, other fossil fuels, briquettes made from a mixture of biomass and fossil fuels, other mixture of biomass and solid fuels
Leo
Olsberg GmbH | Hüttenstraße 38 | 59939 Olsberg | Deutschland
1015-CPR-30-16335/TZ
Engineering Test Institute Hudcova 424/56b, 621 00 Brno,
Tschechien
EN 13240
CEN/TS 15883:2010
no
5,4 kW
0,0 kW
72,13 %
110
A+
Preferred
Other suitable
ηs
fuel (only
fuel (s)
:
[x%]:
3
one):
:
2
yes
yes
72,1
no
yes
72,0
no
no
no
no
Item
P
nom
P
min
el
max
el
min
el
SB
P
pilot
Fire protection and safety distances such as distances to combus-
tible building materials, among others, must be observed under all
circumstances!
A sufficient supply of combustion air for the appliance must be gua-
ranteed at all times. Air-suction systems can interfere with the com-
bustion air supply!
ηth,nom
ηth,min
yes
no
no
no
no
no
no
no
no
Emissions at nominal
Emissions at minimum
heat output
heat output
PM OGC
CO
NOx PM
OGC
[x] mg/Nm3 (13 % O2)
[x] mg/Nm3 (13 % O2)
19
68
94
622
20
72
678
105
Value
5,0
0,0
0,000
0,000
0,000
N. A.
82,5
0,0
4
CO
NOx
Unit
kW
kW
kW
kW
kW
kW
%
%
23

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hki leo 28/9253

Table of Contents