mspa OSLO Owner's Manual
Hide thumbs Also See for OSLO:

Advertisement

Owner's Manual
OSLO
F-OS063W
EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OSLO and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for mspa OSLO

  • Page 1 Owner’s Manual OSLO F-OS063W...
  • Page 2: Table Of Contents

    For FAQ, Manuals, Videos or Spare Parts, please visit www.the-mspa.com/support Due to MSpa's continuous product improvement process, MSpa reserves the right to change the specifications and appearance of its products, which may result in updates to the instruction manual without prior notice. MSpa Official Site...
  • Page 3: Safety Precautions

    IMPORTANT SAFETY INSTRUCTIONS For your own safety and that of your product, make sure to follow the safety precautions below. Fail to follow the instruction may result in serious injury, property damage or death. Improper installation or operation will void the warranty.
  • Page 4 The plug of spa shall be more than 3.5m away from the pool. WARNING: WARNING: Spray head must not be used. WARNING: The outlet of Spa must not be connected to any tap or fitting other than those specified. WARNING: Electric installations should fulfill the requirements of local standards.
  • Page 5 A green coloured terminal or a terminal marked G, GR, Ground, Grounding, or the symbol* is located inside the electric box. To reduce the risk of electric shock, this terminal must be connected to the grounding means provided in the electric supply service panel with a continuous copper wire equivalent in size to the circuit conductors supplying this equipment.
  • Page 6 Warning Label Instruction Please carefully read the warning label at the first time you are going to use MSpa. Please post this warning label on where is at a distance to MSpa within 1.5m/5’, people in spa can see it clearly.
  • Page 7: Specifications

    Notify customer service of any damaged or missing parts at the time of purchase. Plastic wood panel *3 Spa liner with Corner Open-end panel *1 Top trim *4 One with MSpa Logo LED light strip beam *4 Jet Control Box Bottom seal *4 Buckle spa cover...
  • Page 8: First Use And Setup Preparation

    FIRST USE AND SETUP PREPARATION Site preparation and requirements ● The spa can be installed indoors or outdoors in around 15 minutes by 2 persons. For household use only. ● The spa must be set up on a flat, smooth, and supporting surface that can bear the maximum load of the filled spa with the listed maximum number of occupants.
  • Page 9: Spa Setup

    SPA SETUP...
  • Page 10 BUBBLE min. DOWN Long press the BUBBLE button for more than 3 seconds to stop inflation. Connect the light strip cable to the control box.
  • Page 11: Control Operation

    CONTROLLER OPERATION Wi-Fi Icon Low Temperature Warning LED Display Filter Button HEATER Button Ozone Button BUBBLE Button Timer Button Adjust the bubble level by pressing the button (L1:300W, L2:450W, L3:700W ) Up Button DOWN Button JET Button UVC Button LED display °C °F Once powered-up, press the RESET on the GFCI.
  • Page 12 Unlock Lock NOTE: Always keep the spa cover on to minimize heat loss when heating the water. Make sure the cover, and mostly its side facing water, will not come into contact with the ground or any other dirt when not in use.
  • Page 13: Led Light Strip Operation

    Celsius/Fahrenheit Toggle Button The temperature can be displayed in either Celsius or Fahrenheit. Press the DOWN button for 3 seconds to toggle between the two options. SAFETY LOCK Press the UP and DOWN buttons at the same time for 3 seconds to lock/unlock the controller. In safety lock mode, the controller is disabled and the spa retains all previous settings.
  • Page 14: Water Maintenance And Chemicals

    WATER MAINTENANCE AND CHEMICALS CAUTION: ALWAYS ENSURE THE SPA IS UNPLUGGED BEFORE STARTING ANY MAINTENANCE WORK TO AVOID THE RISK OF INJURY OR DEATH. FILTER CARTRIDGE MAINTENANCE 1. Inspect and clean the filter cartridge gently after each use. Follow the steps below: NOTE: Change the filter cartridge every 3-5 days, if the filter cartridge remains soiled and discolored.
  • Page 15: Drainage, Cleaning And Storage

    Water Treatment: ● It is good practice with an existing spa to keep all air jets open and valves closed to allow chemically treated water to flush through all pipework. ● Always follow the chemical manufacturer's instructions and health and hazard warnings. ●...
  • Page 16 Disassemble Instructions Remove all the parts in the reverse order of the installation steps. NOTE: To remove the liner, use an L-wrench to pry the retaining block out of the side panel slot. Do not drag the liner directly. Spa Bladder Deflation 1.
  • Page 17: Precautions For Winter Use

    Storage and Preparation for Future Use 1. Drain and clean the spa by following the “Drainage” and “Spa Cleaning” sections. 2. Refer to the instructions to deflate air bladder. 3. Make sure all the spa components and accessories are thoroughly clean and dry before storage.
  • Page 18: Troubleshooting

    Spa in&outlet connection not Tighten the in&outlet connection securely tight SPA LEAKING Drainage valve is not closed Close the drainage valve. Contact the MSpa Service Center, completely if the spa is still leaking Temperature set too low Set a higher temperature...
  • Page 19: Mspa Limited Warranty

    ● This warranty is valid only in the country of purchase in such countries where MSpa sells and services the same model with identical technical specifications.Warranty service outside the country of purchase is limited to the terms and conditions of the corresponding warranty in the country of service.