Elevator control panel & elevator floor expansion board (13 pages)
Summary of Contents for ZKTeco EC16
Page 1
USER MANUAL Elevator Control Panel & Elevator Floor Extension Board Applicable Models: EC16 & DEX16 Version: 1.1 Date: March 2023 English Thank you for choosing our product. Please read the instructions carefully before operation. Follow these instructions to ensure that the product is functioning properly.
Page 2
ZKTeco supplied equipment vests in and is the property of ZKTeco. The contents hereof should not be used or shared by the receiver with any third party without the express written permission of ZKTeco.
Page 3
ZKTeco shall in no way be responsible (i) in case the machine/unit/equipment malfunctions due to any non-compliance of the instructions contained in this manual (ii) in case of operation of the machine/unit/equipment beyond the rate limits (iii) in case of operation of the machine and equipment in conditions different from the prescribed conditions of the manual.
Page 4
With years of experience in the industrialization of biometric verifications, ZKTeco was officially established in 2007 and now has been one of the globally leading enterprises in the biometric verification industry owning various patents and being selected as the National High-tech Enterprise for 6 consecutive years.
Page 5
EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual Document Conventions Conventions used in this manual are listed below: GUI Conventions For Software Convention Description Bold font Used to identify software interface names e.g., OK, Confirm, Cancel.
EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual Table of Contents 1 SAFETY INSTRUCTIONS ........................7 ..........................7 MPORTANT ECURITY NSTRUCTIONS ..............................8 NSTALLATION AUTIONS 2 OVERVIEW ............................9 ..............................9 YSTEM NTRODUCTION ......................... 9 ACKAGE NCLOSURE NTRODUCTION ..........................
Page 7
EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual 5.3.4 V QR C ............................. 40 ERIFICATION 6 COMMUNICATION CONNECTION ..................... 41 ....................41 CCESS ONTROL ETWORKING IRES AND IRING TCP/IP C .............................. 42 OMMUNICATION ..............................43 ODIFY THE ADDRESS 7 OTHERS ...............................
EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual Safety Instructions Important Security Instructions Before operating the equipment, please read and strictly follow all security and operation instructions. Please keep the instructions in good condition for future reference.
EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual Installation Cautions To protect the wiring from rats, all wires should be placed in pipes. It is recommended to use PVC conduits or galvanized tubes. Although the control panel has a good anti-static, anti-lightning, and anti-leakage design, it is important to ensure that the case of the control panel and the AC ground wire are connected perfectly and the AC ground wire is grounded.
Package C Enclosure Introduction EC16 elevator master controller is a bare board, which can be installed and fixed to Package C enclosure, and the DEX16 expansion board supports stacking and fixing on the master control board.
EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual Description Description Floor Button Control Port Power Input Extend Port Ethernet Interface (LAN1) Wiegand TCP/IP Reader Interface (LAN2) RS-485 U disk interface LED Indicator Reset Button Elevator Door Closing Button...
User Manual LED Indicators Description LED indicators on the EC16 When the EC16 elevator controller is powered on, the LED indicators under normal circumstances will show the following. Figure 1-3 LED indicator diagram of the elevator controller POWER indicator (Red): ...
EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual Terminal Instructions Figure 3-1 Terminal diagram of the elevator controller and the expansion board The terminals are described as follows: Terminal Number Description Floor Button Used to connect elevator buttons for floor selection control.
Page 15
DIP Switch order of the expansion board and follow the operation prompt next to it. Used to connect the signal output terminal of the EC16 controller (i.e. Extend RS-485 Input Port) or the signal output terminal of the upper level DEX16.
EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual Wiring Description Elevator Controller Networking Cabling Figure 4-1 Diagram of elevator controller networking cabling Note: Make sure the power is turned off before wiring. Wiring in the energized state may cause serious damage to the equipment.
EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual Connection Power Supply This device uses the adapter matched with the Package C enclosure to supply power to the elevator controller, providing a 12V power supply which takes into account the power consumption of the elevator controller itself, the power consumption of up to seven DEX16 expansion boards and the output power consumption of the RS-485 reader.
EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual Ethernet Connection to the Computer Connect the elevator controller and the computer software via Ethernet cable. The wiring is shown in the following diagram. Figure 4-3 Ethernet wiring diagram...
EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual Elevator Control and Elevator Button Wiring Elevator Button Wiring Description Figure 4-4 Elevator button wiring schematic Instruction: Connect Signal Cable 1 to the NO terminal on the corresponding floor of the elevator logic controller. After Signal Cable 2 is disconnected, COM and NC terminals are connected to the COM and NC terminals of the corresponding floor respectively.
EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual Instruction: S1 and S2 switches are two relays (S1 relay is normally closed and S2 relay is normally open) of the elevator control board respectively. S1 is disconnected after power on, and S1 is closed after swiping the layer selection card, then the elevator button can be lit by pressing;...
Page 21
EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual When the FIRE interface becomes a short circuit, all the keys of the elevator cannot be lit normally. If you want to cancel the "fire" function, please log in ZKBio CVSecurity software, click [Elevator] >...
Note: Use the software setup after connecting the DEX16 module to the EC16 master controller. A maximum of seven DEX16 extended boards can be connected to one EC16 controller.The total can be expanded to 128 layers at most. Before power is supplied, use the DIP switch to set the RS-485 addresses of the DEX16s, following the order in which each DEX16 is connected.
Elevator Controller System Power Supply Structure Figure 4-9 Diagram of elevator controller system power supply structure The EC16 elevator controller is powered by +12V DC power supply. When using +12V DC power supply, generally speaking, in order to reduce the influence of power interference between elevator controllers, each elevator controller should be powered separately.
EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual Elevator control operating instructions Connect to ZKBio CVSecurity Software The elevator controller needs to be connected to the software and set the corresponding parameters to use the elevator control function in the software system, and can manage the equipment through the system, upload the user's elevator control data, download the configuration information and output various reterminals to realize the digital management of the enterprise.
EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual 5.1.2 Add Device on the Software Add elevator control device by searching, the operation process is as follows. Click [Elevator] > [ElevatorDevice] > [Device] > [Search], to open the Search interface in the software.
EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual Note: When the device cannot be added to the software, please check the following information. When the device can not be added, please check whether the communication is HTTP or HTTPS.
EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual 5.1.4 Add Expansion Board on the Software Click [Elevator] > [Elevator Device] > [Expanding Board] to enter the setting interface. Click[New] to add a expanding board. Click [Device Name] and select the expansion board in the pop-up window.
Connect the VCC, GND, 485A and 485B terminals of the reader to the RS-485 communication terminal of the elevator controller, and the wiring is shown in the following figure. Figure 5- 1 Wiring Schematic of RS-485 Reader and EC16 Elevator Controller Set the 485 addresses (machine number) of the reader by software.
Page 30
EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual Each EC16 can connect a maximum of eight RS-485 readers, as shown in the figure below. Figure 5- 2 Wiring diagram of elevator controller and multiple RS-485 readers...
The reader should be installed about 55 inches (1.4m) from the ground and 0.1 inches to 0.2 inches (30 to 50mm) from the door edge frame. Figure 5- 3 Wiring Diagram of EC16 Elevator Controller and Wiegand Reader 5.1.6 Set Elevator Control Rules on Software Note that when setting elevator control rules, when the "Direct Selection Set"...
Page 32
EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual 5.1.6.1 Set Elevator Control Levels Group Click [Elevator] > [Elevator Control Rule] > [Elevator Levels] to enter the setting interface. Click [New] to add a new elevator control level group.
Page 33
EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual 5.1.6.2 Set Access by Levels Add personnel to the elevator control level group. Click [Elevator] > [Elevator Control Rule] > [Set Access By Levels] to enter the setting interface.
Page 34
EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual 5.1.6.4 Set Access By Department Edit the elevator control level group for the department. Click [Elevator] > [Elevator Control Rule] > [Set Access By Department] to enter the setting interface.
Page 35
EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual In the Add direct selection layer pop-up window, click on the drop-down menu to select the elevator device, direct floor and time zones. Click [OK] to save and exit.
EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual User Verification on the QR-600 Series Readers When the QR-600 Series Reader successfully communicates with the elevator controller (see 5.1.5 Add Reader on the Software for details on the connection method), the user can verify on the QR-600 series reader.
Page 37
EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual Open the App on the Smartphone. On the login screen, tap [Server Setting] and type the IP Address or the Domain Name of the Server, and its Port Number.
EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual Note: The APP's network connection and the server's network connection need to be in the same LAN, otherwise the network will be unavailable. 5.3.2 Login Initially, it is required to configure the Server Settings before login. After the Server settings are successfully saved, it will automatically return to the login screen.
Page 39
EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual Employees can login with the Personnel ID in [Personnel] > [Personnel] > [Person] and self- service password. The default self-service password is 123456. The employee login diagram is shown in the figure:...
EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual The Administrator and Employee can change the Password in the App System Settings. Notes: The license determines the number of available Mobile App connections. Users can view it by clicking [Personal Information] >...
EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual 5.3.4 Verification QR Code After logging into the ZKBioSecurity Mobile App as an employee, click on the mobile credential icon and bring up the QR code to verify on the reader. After successful verification, you can go straight to the authorized floor or you can light up the authorized floor manually.
EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual Communication Connection The backend PC software is able to communicate with the system via TCP/IP for data exchange and remote management. Communication lines are as far away from high-voltage power lines as possible, and should not be wired in parallel with power lines, let alone bundled together.
EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual TCP/IP Communication The Ethernet 10/100Base-T Crossover Cable, a type of crossover network cable, is mainly used for cascade hubs and switches, or used to connect two Ethernet end-points directly without a hub. Both 10Base-T and 100Base-T are supterminaled.
EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual 6. The factory default IP address of the device is: 192.168.1.201, after the device is added successfully, you can modify the IP address of the device in the communication column. Select the device, click [Elevator] >...
Page 45
EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual Select the device to be modified, click the icon to modify the IP address of the device, click [OK] after setting the parameters, as the following figure shows.
Page 46
EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual Modify the IP address of Network card 1 in the pop-up window. Click [OK] to save and exit. Note: Network card 1 is the IP address of the primary NIC of the elevator controller, and Network card 2 is the IP address of the extended NIC of the elevator controller.
If the upgrade is unsuccessful, the elevator controller will return to normal operation. Restore Factory Settings The EC16 elevator controller can be restored to factory settings by [RESET] key. Press the [RESET] button, 1 to 5 seconds to upgrade with USB disk, 5 to 10 seconds to restart the controller, 10 seconds or more to restore the factory settings.
User Manual Appendix 1 Buzzer, Indicator Light Prompt Instructions EC16 elevator controller works normally online, when the user verifies the RFID card in RS-485 reader and Wiegand reader, the buzzer and indicator prompts are shown in the following table. Working Status...
Appendix 2 Privacy Policy Notice: To help you better use the products and services of ZKTeco and its affiliates, hereinafter referred as “we”, “our”, or “us”, the smart service provider, we consistently collect your personal information. Since we understand the importance of your personal information, we took your privacy sincerely and we have formulated this privacy policy to protect your personal information.
Page 50
EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual 3. Only your user ID is displayed by default. You can set whether to display other user verification information (such as Name, Department, Photo, etc.) under the Administrator privilege.
EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual Appendix 3 Eco-friendly Operation The product's "eco-friendly operational period" refers to the time during which this product will not discharge any toxic or hazardous substances when used in accordance with the prerequisites in this manual.