Download Print this page

Sony SEL16F28 Adjustment Manual page 2

Interchangeable e-mount lens
Hide thumbs Also See for SEL16F28:

Advertisement

1. PREPARATIONS
Equipment used
• Personal Computer (Note 1)
• B-L Control Box (J-6082-774-A)
(Supplied with D-sub 15-pin cable)
• AC cable (Sold on the market)
• RS-232C Cable (D-sub 9-pin (Male with securing screws), D-sub 9-pin (Female with securing screws)) Straight type (Sold on the market)
• USB to serial cable (D-sub 9-pin (Male)) (Sold on the market)
• Lens adjustment program (BLG-TestProgramV[][][].exe) (Note 2)
Note 1:
Personal computer must have the condition that Windows XP/Vista/7 runs normally and USB is connectable.
Note 2:
Obtain the lens adjustment program (BLG-TestProgramV[][][].exe) from the TISS homepage.
1-1. Connection
Connect equipment as shown below.
D-sub 15-pin cable
(Connect to lens mount block)
B-L Control Box
D-sub 9-pin: Male
AC Cable
RS-232C Cable
D-sub 9-pin: Female
USB to Serial Cable
Fig. 1-1-1
1-2. Installation of Lens Adjustment Program
1. Download the file " BLG-TestProgramV[][][].zip " from the TISS homepage, save and extract it.
2. Save " BLG-TestProgramV[][][].exe " in an arbitrary folder.
Note:
The version of " BLG-TestProgram " may be updated without notice.
1-3. Start of Lens Adjustment Program
1. Mount a lens to be tested to the lens mount block.
2. Connect the D-sub 15-pin cable to the lens mount block, and turn on the B-L Control Box.
3. Start " BLG-TestProgramV[][][].exe " .
Fig. 1-3-1
E-MOUNT LENS GENERAL ADJUSTMENT GUIDE
4. Click [Open] to connect communication with the B-L Control Box.
Note:
When the B-L Control Box or personal computer to be used is started for the first time, a password must be entered.
Fig. 1-3-2
When the password input window opens, ask HQ about password. In this case, the ID shown in " COM / USER Characteristic Number " must be
informed ( " YdDGAAHTJ " in the example above).
Since this ID number is unique to the B-L Control Box and personal computer, if a password is used for another B-L Control Box or personal
computer, another password is necessary.
5. Enter a password and click [OK]. Connection to the lens mount block is established and the [Power] button is made active.