    Transport and storage............ 6 Assembly and start-up............ 7 ® Airozon 10000 Operation ................ 8 Available accessories............ 10 https://hub.trotec.com/?id=44531 Errors and faults.............. 10 Safety Maintenance ................ 11 Technical annex.............. 12 Read this manual carefully before starting or using the device. Always store the manual in the immediate vicinity Disposal ................ 15...
  • Page 3 Order a new power cable with mains plug from ozone from escaping to the environment. Trotec and replace the defective power cable with mains • Clearly indicate a room's ozone treatment for others and plug with the new one.
  • Page 4 Foreseeable misuse Warning Risk of injury caused by inhalation of ozone! • Do not use the device as private individual or at home / in The following symptoms could be indicative of a domestic environment. poisoning or an irritation caused by ozone: •...
  • Page 5: Information About The Device

    Depending on the concentration, ozone can have a very intense Information about the device smell similar to chlorine, hay or carnations, odours that can be smelled in mountain areas. By nature, the human nose is Device description already vastly superior to most measuring devices: It detects the Ozone is a very powerful oxidising agent with the ability to gas with a concentration of as little as 0.01 ml/m .
  • Page 6: Transport And Storage

    Device depiction Designation Air outlet Operating hours counter Mains supply Power adapter Ozone electrode Air inlet Timer switch On/off switch with operating light LED display Housing Transport and storage Note If you store or transport the device improperly, the device may be damaged. Note the information regarding transport and storage of the device.
  • Page 7: Assembly And Start-Up

    • When positioning the device, keep a sufficient distance to Assembly and start-up heat sources. • Make sure that no curtains or other objects interfere with Scope of delivery the air flow. • 1 x manual • Do not position the device near inflammable substances •...
  • Page 8: Operation

    Info Operation The device comes with a switch-on delay function of one minute. Take into consideration that no ozone will Note be generated during the first minute of the set Avoid open doors and windows. treatment duration yet. Always set the treatment Operating elements duration to more than one minute.
  • Page 9 (vomit) neutralisation. 1. Set the desired treatment duration by means of the timer. Please contact the Trotec customer service if you are using the 2. Set the on/off switch (9) to I to switch the device on. device for disinfection purposes.
  • Page 10: Available Accessories

    • Wait for 10 minutes before restarting the device. If the device is not starting, have the electrics checked by a A certain waiting period must be observed between the device specialist company or by Trotec. switch-off and accessing the treated room. The device is very loud: At the end of the waiting period the room must be aired out extensively.
  • Page 11: Maintenance

    Cleaning the housing Maintenance Clean the housing with a soft, damp and lint-free cloth. Make Activities required before starting maintenance sure that no moisture enters the housing. Protect electrical components from moisture. Do not use any aggressive cleaning Note agents such as cleaning sprays, solvents, alcohol-based or The device must be maintained at least once a abrasive cleaners to dampen the cloth.
  • Page 12: Technical Annex

    Cleaning the electrode Technical annex Note Technical data Device damage due to missing electrode! Never operate the odour neutraliser without inserted Parameter Value electrode! Model Airozon 10000 The electrode may be cleaned whilst built-in. Article number 1.180.000.112 1. Prior to cleaning check the electrode for cracks or Electric connection 230 V breakage.
  • Page 13 Circuit diagram Ozone generator Airozon® 10000...
  • Page 14 Overview and list of spare parts Note: The position numbers of the spare parts differ from those describing the positions of the components mentioned in these instructions. Item Designation Item Designation Handle Operating hours counter Cover Housing Air filter cover Net filter Air filter Power connection with fusing...
  • Page 15: Disposal

    Directive 2006/42/EC, Annex II, Part 1, Section A disposal regulations. We – Trotec GmbH – declare in sole responsibility that the product designated below was developed, constructed and The icon with the crossed-out waste bin on waste...