  • Page 1 ® AIROZON SUPERCRACKER ORIGINAL INSTRUCTIONS OZONE GENERATOR...
  • Page 2: Table Of Contents

    Transport and storage............ 6 ® Airozon Assembly and start-up............ 7 Supercracker Operation ................ 8 Available accessories............ 11 https://hub.trotec.com/?id=39949 Errors and faults.............. 11 Safety Maintenance ................ 12 Technical annex.............. 13 Read this manual carefully before starting or using the device. Always store the manual in the immediate vicinity Disposal ................ 16...
  • Page 3 Trotec (OZ-ONE) or in a Defective power cables pose a serious health risk! specialist shop. Wear a respirator mask with ozone filter.
  • Page 4 Personnel qualifications Warning Risk of injury caused by inhalation of ozone! People who use this device must: The following symptoms could be indicative of • have been trained in handling the device and be aware of poisoning or an irritation caused by ozone: the dangers that occur when working with the oxidising - eye irritations –...
  • Page 5: Information About The Device

    Depending on the concentration, ozone can have a very intense Information about the device smell similar to chlorine, hay or carnations, odours that can be smelled in mountain areas. By nature, the human nose is Device description already vastly superior to most measuring devices: It detects the Ozone is a very powerful oxidising agent with the ability to gas with a concentration of as little as 0.01 ml/m .
  • Page 6: Transport And Storage

    Device depiction Transport and storage Note If you store or transport the device improperly, the device may be damaged. Note the information regarding transport and storage of the device. Note Device may be damaged by vibration. Excessive vibrations can result in electrode damage. To prevent this, always protect the odour neutraliser from vibrations or slipping during transport.
  • Page 7: Assembly And Start-Up

    Start-up Assembly and start-up When positioning the device, observe the minimum distance Scope of delivery from walls or other objects as described in the chapter Technical annex. • 1 x device • 1 x Power cable • 1 x Transport handle • 1 x manual Unpacking the device 1.
  • Page 8: Operation

    Connecting the power cable Setting the operating mode • Insert the mains plug into a properly secured mains socket The following operating modes can be set on the device: located outside of the room to be cleaned. This enables • Disinfection you to switch the device off in case of an emergency •...
  • Page 9 The manual mode can only be used with an activation code. If 3. Make sure that neither humans nor animals are situated in you need this code, please contact the Trotec customer service. the room to be cleaned. The entry of the code can be corrected using CLR and DEL. By 4.
  • Page 10 (vomit) off switch for reasons of safety. In that event, the mains plug located outside of the treated room should be disconnected Please contact the Trotec customer service if you are using the from the power supply. device for disinfection purposes.
  • Page 11: Available Accessories

    ZZ7000275 device is not starting, have the electrics checked by a Professional extension cable 7.333.000.376 specialist company or by Trotec. 20 m / 230 V / 2.5 mm² The device is very loud: • Position the device on a dry, firm and level surface. • Check whether the fan and its bearing for damage. If you detect any damage, have the device checked by a certified specialist workshop.
  • Page 12: Maintenance

    Cleaning the housing Maintenance Clean the housing with a soft, damp and lint-free cloth. Make Activities required before starting maintenance sure that no moisture enters the housing. Protect electrical components from moisture. Do not use any aggressive cleaning Warning of electrical voltage agents such as cleaning sprays, solvents, alcohol-based or Do not touch the mains plug with wet or damp hands.
  • Page 13: Technical Annex

    Upon delivery top (A): 50 cm of a replacement filter, this code will be provided by Trotec. rear (B): 50 cm It is possible to view the remaining useful life before the At the sides (C):...
  • Page 14 Overview and list of spare parts Note: The position numbers of the spare parts differ from those describing the positions of the components mentioned in these instructions. Item Designation Item Designation Front panel Operation indicator Ozone exhaust pipe Axial fans Lid for ozone air outlet Protection Rubber foot, front...
  • Page 15 Circuit diagram Ozone generator Airozon® Supercracker...
  • Page 16: Disposal

    Directive 2006/42/EC, Annex II, Part 1, Section A disposal regulations. We – Trotec GmbH – declare in sole responsibility that the product designated below was developed, constructed and The icon with the crossed-out waste bin on waste...
  • Page 17 Trotec GmbH Grebbener Str. 7 D-52525 Heinsberg +49 2452 962-400 +49 2452 962-200 info@trotec.com www.trotec.com...