Maintenance; Printed Board Functions And Indicator Lamps; Configuring The Board; Software Update - Necta Snakky Max Instructions For Installation, Use And Maintenance Manual

Hide thumbs Also See for Snakky Max:
Table of Contents

Advertisement

Chapter 3

MAINTENANCE

The maintenance operations described in this chapter
should be carried out with the machine energised and
therefore by qualified personnel, who are trained in the
correct use of the machine and are aware of the specific
risks of such condition.
To energize the system with the open door, simply insert
the special key into the switch on the payment system
compartment door (see Fig. 24).
Inside the machine, the only parts that stay energised
are those protected by covers and carrying a plate with
the warning "Disconnect the power before removing
the protective cover".
Before removing such covers disconnect the machine
from the power grid.
The integrity of the machine and compliance with the
standards of the relevant systems must be checked at
least once a year by qualified personnel.
PRINTED BOARD FUNCTIONS
AND INDICATOR LAMPS
The C.P.U. (Central Processing Unit) board controls all
users set for the maximum configuration of the spiral
compartment and processes the input signals from the
keypad, the payment system and the cooling unit sensors.
The card also houses some LEDs which, during the
machine operation, give the following indications:
- Green LED (3): blinks during normal operation of the
C.P.U. board;
- Yellow LED (4): glows when 5 V DC are detected;
- Red LED (7): glows when, for any reason, the software
is reset.

CONFIGURING THE BOARD

This board is preset also for the MDB protocol.
The 4 dip-switches for setting the SW2 coin mechanism
(see Fig. 17) should be set to OFF for Executive-BDV and
to ON for MDB.

SOFTWARE UPDATE

The machine is fitted with a Flash EPROM which can be
electronically updated.
By means of a special program and suitable system
(UpKey, Personal Computer or similar) the machine man-
agement software can be updated without replacing the
EPROM.
Warning!
When downloading the software it is advisable to discon-
nect the motor connectors from the CPU board (J1 e J2).
© by NECTA VENDING SOLUTIONS SpA
Fig. 17
1
- J14 Coin mechanism power supply
2
- J15 Board power supply
3
- Green LED: run (DL2)
4
- Yellow LED: 5 V DC (DL1)
5
- J1 Dispensing compartment connection
6
- J2 Spiral motor control
7
- Red LED: CPU reset (DL3)
8
- J3 Input/output
9
- J17 UpKey connection
10
- J4 Not used
11
- J5 RS232
12
- J6 Photocells
13
- J7 Can-Bus
14
- Button not used
15
- J8 Validators
16
- J9 Probe
17
- J10 LCD display
18
- J11 Direct selection keypad
19
- J16 Keypad
20
- J12 MDB expansion
21
- Coin mechanism setting minidips (SW2)
22
- J13 Expansion for BDV / EXE
25
0407 239 -00

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents