e will be sent again.
2. Data sending status prompt
OK+SEND:TX_LEN indicates that the data sending request is suc
cessful, TX_LEN: 1Byte, the length of the data sent
OK+SENT: TX_CNT means that the data is sent successfully, TX
_CNT: 1Byte, the number of data sending.
ERR+SEND:ERR_NUM indicates that the data sending request fai
led, and the reason is indicated by ERR_NUM. ERR_NUM: 1Byt
e,
0- Not connected to the network
1- Communication is busy, send request failed
2- The data length exceeds the current sendable length, only send
the MAC command
ERR+SENT: TX_CNT indicates that the data transmission failed,
and the number of transmissions reaches the maximum number. T
X_CNT: 1Byte, the number of data transmissions.
OK+RECV:TYPE,PORT,LEN,DATA Data received successfully (res
ponse message or active downlink data received)
TYPE: 1Byte, downlink transmission type
Bit0: 0-unconfirm, 1-confirm
Bit1: 0-Not ACK, 1-ACK
Bit2: 0-not carried, 1-carried, indicating whether the downlink data
carries the LINK command response
Bit3: 0-not carried, 1-carried, indicating whether the downlink data
carries the TIME command response, only when the bit is 1, it
means the time synchronization is successful
Bit4~Bit7: Default 0, reserved
PORT: 1Byte, downstream transmission port
LEN: 1Byte, downlink data length
DATA: nByte, downstream data, when LEN=0, this field does not
exist.