Warranty ITECH warrants that the product will be free from defects in material and workmanship under normal use for a period of one (1) year from the date of delivery (except those described in the Limitation of Warranty below).
Page 4
Failure to comply with these precautions or specific warnings elsewhere in this manual will constitute a default under safety standards of design, manufacture and intended use of the instrument. ITECH assumes no liability for the customer’s failure to comply with these precautions.
The following is a detailed description of the bracket. IT-E158A The IT-E158A is a kit for installing 2 instruments side-by-side into an ITECH cabinet. Contains a mounting handle at the front of the instrument, a fixing piece connecting the middle of the 2 instruments, and a fixing piece at the rear of the instrument.
Rear mounting connector (for fixing instrument) IT-E158C The IT-E158C is a kit for mounting a single instrument into an ITECH cabinet (with a baffle on the other side). Includes mounting handle at the front of the instrument, baffle plate, and fixing piece at the rear of the instrument.
Hexagon socket cheese head combination screw M5x12 IT-E158D The IT-E158D is a kit for mounting a single instrument into a non-ITECH cabinet (with a baffle on the other side). Includes mounting handle at the front of the instrument, a baffle plate, and a retractable fixture at the rear of the instrument.
Installation Instruction Chapter2 Installation Instruction 2.1 Instrument Preparation Before installing the IT-E158 kit, the instrument handle and rubber protective sleeve need to be removed, as detailed below (take the IT2801 SMU as an example). Do not block the air inlet holes on the side of the instrument and the air exhaust holes on the rear panel.
2.2 Installation of a single instrument Installation into ITECH cabinet (select IT-E158C) When installed into the ITECH cabinet, the installation method is shown below. Fasten the cross countersunk head screws M4x10 (4pcs) in the IT-E158C kit to the mounting lugs as shown by the red arrows in the figure below.
Page 16
Fasten the cassette nut combination (4pcs) in the IT-E158C kit to the rear mounting lug connector (2pcs) and the square hole strip in the middle of the side of the ITECH cabinet as shown by the red arrow in the figure below.
Installation into non-ITECH cabinets (select IT-E158D) When installed into a non-ITECH cabinet, the installation method is shown...
Page 18
Installation Instruction below. Fasten the cross countersunk head screws M4x10 (4pcs) in the IT-E158D kit to the mounting lugs as shown by the red arrows in the figure below. Install the cross small pan head screws M4x8 (12pcs) in the IT-E158D kit to both sides of the instrument as shown by the red arrows in the figure below.
Page 19
Installation Instruction the front mounting ears of the instrument and the cabinet. Note: When there is no pallet load-bearing inside the cabinet, it is recommended that at least two people cooperate in the operation, with one person making sure to hold the instrument while the others lock the screws and other operations.
2.3 Installation of two instruments Installation into ITECH cabinet (select IT-E158A) When installed into the ITECH cabinet, the installation method is shown below. Fasten the cross countersunk head screws M4x10 (4pcs) in the IT-E158A kit to the mounting lugs as shown by the red arrows in the figure below.
Page 21
Installation Instruction Install the cross small pan head screws M4x8 (8pcs, shown by red arrows) and cross countersunk head screws M4x10 (8pcs, shown by blue arrows) to both sides of the instrument as shown by the arrows in the figure below. According to the red arrow shown in the figure below, first merge the connection pieces in the middle of the two instruments (at note A in the figure), and after aligning the mounting holes in the middle, fasten them (at...
Page 22
Fasten the cassette nut combination (4pcs) to the rear mounting lug connectors (2pcs) and the square hole strip at the middle of the side of the ITECH cabinet as shown by the red arrow in the figure below. The installation schematic for one side is as follows.
Installation into non-ITECH cabinets (select IT-E158B) When installed into a non-ITECH cabinet, the installation method is shown below. Fasten the cross countersunk head screws M4x10 (4pcs) in the IT-E158B...
Page 24
Installation Instruction Install the cross small pan head screws M4x8 (8pcs, shown by red arrows) and cross countersunk head screws M4x10 (8pcs, shown by blue arrows) to both sides of the instrument as shown by the arrows in the figure below. According to the red arrow shown in the figure below, first merge the connection pieces in the middle of the two instruments (at note A in the figure), and after aligning the mounting holes in the middle, fasten them (at...
Page 25
Installation Instruction Fasten the cassette nut assembly (4pcs) to the rear mounting lug connectors (2pcs) and the square hole strip on the side of the cabinet as shown by the red arrow in the figure below. Drop the instrument with the carrying handle and rear end connector installed into the cabinet and fasten the cassette nut combination (4pcs) to the front mounting ears of the instrument and the cabinet.
Page 26
Installation Instruction Adjust the length of the retractable kit according to the depth of your cabinet. Fasten the hexagonal socket head combination screws M5x12 (4pcs) to the rear mounting lug connections already installed on the cabinet and already installed on the rear of the instrument as shown by the red arrows in the figure below.
Page 27
Installation Instruction After the installation is completed, the side is shown below (shortest and longest).
Page 28
Contact Us Thanks for purchasing ITECH products. In case of any doubts, please contact us as follows: 1. Visit ITECH website: www.itechate.com. 2. Select the most convenient contact method, for further information.
Need help?
Do you have a question about the IT-E158 and is the answer not in the manual?
Questions and answers