The optional Steffes ½ HP (Item #1302132 and ¾ HP (Item #1302134) variable speed air handlers are used to
interface a Comfort Plus Hydronic with a centrally ducted heating or cooling system. Each air handler includes
a plenum assembly, variable speed supply air blower, water coil. air filter, and installation kit.
When the Comfort Plus Hydronic system receives a heat call from the air handler's room thermostat, the
primary loop pump (circulator) is energized to circulate water through the heat exchanger. At the same time,
the air handler's pump (circulator) and the variable speed supply air blower are energized. The pump circulates
hot water through the air handler's water coil and the variable speed supply air blower extracts heat from the
water in the coil and delivers it to the appropriate heating zone through the ductwork. Since the air handler is
attached to the side of the Comfort Plus Hydronic system, it also provides automatic static heat recovery. If
used with a heat pump, the air handler monitors outlet air temperatures and provides comfort modulation.
Maximum Static Pressure
Maximum Water Coil Output (See Note)
Maximum A-Coil Size - Front Access
Voltage
Full Load Amps (240/208V)
Supply Air Blower
Filter
Standard Copper Pipe Size
NOTE: If using the ¾ or 1 HP Air Handler, the 90,000 BTU/hr coil output may decrease when using an
A-coil smaller than 5 ton.
Figure 1
½ HP
23.69"
23.5"
VARIABLE SPEED AIR HANDLER
OPERATION
SPECIFICATIONS & DIMENSIONS
.75 inches H
60,000 BTU/hr
22 5/16" W x 30" H x 22 3/4" D
¾ HP
23.69"
26.5"
Page 1 of 5
INSTALATION INSTURCTIONS
FOR 5100 & 7100 SERIES
1/2 HP
O
2
240/208 VAC
4.3/5.0
1/2 HP, 60 HZ
20" x 20" x 2"
3/4"
3/4 HP
.75 inches H
90,000 BTU/hr
25 5/16" W x 33" H x 22 3/4" D
240/208 VAC
6.8/7.3
3/4 HP, 60 HZ
20" x 25" x 2"
3/4"
Figure 2
Document #1200365 Rev 10
O
2
Supply Air
Outlet
Blower Access
Coil Access
Filter Access
09/04/2020

Advertisement

loading
Need help?

Need help?

Do you have a question about the 5100 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Steffes 5100 Series

  • Page 1 FOR 5100 & 7100 SERIES The optional Steffes ½ HP (Item #1302132 and ¾ HP (Item #1302134) variable speed air handlers are used to interface a Comfort Plus Hydronic with a centrally ducted heating or cooling system. Each air handler includes a plenum assembly, variable speed supply air blower, water coil.
  • Page 2: Installation

    V ar i abl e S pe ed A ir H and le r In st ru ct i on s( c o n t in ued ) . . . INSTALLATION THIS PROCEDURE MUST BE PERFORMED BY A QUALIFIED TECHNICIAN NOTE: Per UL requirements, the air handler must be mounted to the right side of the Comfort Plus Hydronic system.
  • Page 3 V ar i abl e S pe ed A ir H and le r In st ru ct i on s( c o n t in ued ) . . . 14. Connect the 7-pin harness to the port Outdoor Sensor Connections labeled “Blower”...
  • Page 4 V ar i abl e S pe ed A ir H and le r In st ru ct i on s( c o n t in u ed ) . . . Figure 12 Single Stage Heat Pump Application Hydronic Heat Thermostat, Zone Valve, End Switch, or Pump Control Honeywell TH5220D To Heat Pump...
  • Page 5: Freeze Protection

    Air Handler may not be acceptable for other heating zones in the installation. coil and provide comfort modulation. Steffes It is the responsibility of the installer to ensure that recommends a Taco 007 single speed 115 proper tempering devices are in place.

This manual is also suitable for:

7100 series