Summary of Contents for Novelan LA Compact Station 1E
Page 1
Operating Manual Accessories for Air/Water heat pumps Outdoor Installation LA Compact Station 1E LA Compact Station 2E 83054003dUK – Translation into English of the original German operating manual – Subject to change without notice. w w w.novelan.com...
Indicates suggestions that help to save energy, raw materials and costs. Reference to other sections of the operating manual. Reference to other instructions of the manufac- turer. 83054003dUK – Translation into English of the original German operating manual – Subject to change without notice. www.novelan.com...
LA 7.1 – LA 18 ..............24 Legend Hydraulic integration..........25 TERMINAL DIAGRAM ..............26 CIRCUIT DIAGRAM Compact Station 1E ...............27 Compact Station 2E ...............28 83054003dUK – Translation into English of the original German operating manual – Subject to change without notice. www.novelan.com...
For a current list and additional partners of the manuf- acturer, please visit www.novelan.com. You can operate and control the heat pump system wi- th the control element of the heating and heat pump re- gulator.
Any defects or incorrect deliveries must be claimed immediately.. NOTICE. Note the model. Overview “Technical data/scope of delivery” or rating plate on unit. 83054003dUK – Translation into English of the original German operating manual – Subject to change without notice. www.novelan.com...
– Take suitable precautionary measures to eliminate the danger of tipping. ATTENTION Moving the unit without the feet mounted can damage the floor. 83054003dUK – Translation into English of the original German operating manual – Subject to change without notice. www.novelan.com...
(heating element not included in delivery; heating element for hot water tank up to max. 1 x EHZ 45F) 13 Electrical switch cabinet 83054003dUK – Translation into English of the original German operating manual – Subject to change without notice. www.novelan.com...
Install hot water connections to the heat pump based on the specifications of the heat pump guide below frost penetration depth. Heat pump guide. 83054003dUK – Translation into English of the original German operating manual – Subject to change without notice. www.novelan.com...
Follow specifications of the terminal diagram for electrical connections… “Terminal diagram” for respective model. 83054003dUK – Translation into English of the original German operating manual – Subject to change without notice. www.novelan.com...
If electric heating elements are installed, you are and compact station (heating water outlet to heat responsible for the fuse protection of these. pump)… „Dimensional drawings“ 83054003dUK – Translation into English of the original German operating manual – Subject to change without notice. www.novelan.com...
Page 12
HYDRAULIC TOWER 2 Follow the instructions from compact stati- on 1E… NOTICE. When delivered, the valve is set to hot water. 83054003dUK – Translation into English of the original German operating manual – Subject to change without notice. www.novelan.com...
Rinse the hot water tank until air no longer emerges from the valves at the taps… Close hot water valves at the taps. 83054003dUK – Translation into English of the original German operating manual – Subject to change without notice. www.novelan.com...
0 °C 10 °C 20 °C 30 °C 10 K Open valves to heating circuit… Reset the heating and heat pump controller. 83054003dUK – Translation into English of the original German operating manual – Subject to change without notice. www.novelan.com...
Page 15
Stick the heating and heat pump regulator’s control cable into the right bushing on the bottom of the control element… 83054003dUK – Translation into English of the original German operating manual – Subject to change without notice. www.novelan.com...
Thereafter, remove the snap-in lugs from the opposite side. 83054003dUK – Translation into English of the original German operating manual – Subject to change without notice. www.novelan.com...
The battery can be pushed out using a screwdriver. Dispose of battery and elec- tronic components in keeping with environ- mental considerations. 83054003dUK – Translation into English of the original German operating manual – Subject to change without notice. www.novelan.com...
Factory setting (adjust when commissioning the system) Sound Sound pressure level in free field/sound conducting level dB(A) ı dB(A) UK813300L *) comply with local regulations 83054003dUK – Translation into English of the original German operating manual – Subject to change without notice. www.novelan.com...
Page 19
• • • ı 25 ı 1,5 • ı 50 ı 1,5 • • 35 / 49 35 / 49 813300a 813301d 83054003dUK – Translation into English of the original German operating manual – Subject to change without notice. www.novelan.com...
Seite: 1/1 - / PEP 021-2006 / Stannow / 22.06.07 Zeichnungsnummer: 812022 a/ÄM 0072-2015/Liska/25.01.2015 Datei: 812022b Externe Pressung HT 1 b/ÄM 001-2016/Liska/25.02.2016 83054003dUK – Translation into English of the original German operating manual – Subject to change without notice. www.novelan.com...
- / PEP 021-2006 / Stannow / 22.06.07 Zeichnungsnummer: 812023a a /ÄM 013-2013 / Liška / 17.06.2013 Datei: 812023a Externe Pressung HT 2 83054003dUK – Translation into English of the original German operating manual – Subject to change without notice. www.novelan.com...
R 1¼" Kaltwasser R1" R1" Heizwasser Austritt (zur Wärmepumpe) R1" R1 1/4" 10 Heizwasser Eintritt (von der Wärmepumpe kommend) R1" R1 1/4" 819286 83054003dUK – Translation into English of the original German operating manual – Subject to change without notice. www.novelan.com...
Minimum room height 2100 Top edge of finished floor 20 Distance to next object Shaded area = free space for service purposes 83054003dUK – Translation into English of the original German operating manual – Subject to change without notice. www.novelan.com...
Hydraulic integration with LA 7.1 – LA 18 83054003dUK – Translation into English of the original German operating manual – Subject to change without notice. www.novelan.com...
Compact Station 1E / Compact Station 2E Terminal diagram 3~PE/400V/50Hz 3~N/PE/400V/50Hz 3~N/PE/400V/50Hz 1~N/PE/230V/50Hz B10 A ZW2/SST 83054003dUK – Translation into English of the original German operating manual – Subject to change without notice. www.novelan.com...
Circuit diagram Compact Station 1E yellow white Green Brown 83054003dUK – Translation into English of the original German operating manual – Subject to change without notice. www.novelan.com...
Compact Station 2E Circuit diagram yellow white Green Brown 83054003dUK – Translation into English of the original German operating manual – Subject to change without notice. www.novelan.com...
Page 29
83054003dUK – Translation into English of the original German operating manual – Subject to change without notice. www.novelan.com...
Page 30
83054003dUK – Translation into English of the original German operating manual – Subject to change without notice. www.novelan.com...
Page 31
83054003dUK – Translation into English of the original German operating manual – Subject to change without notice. www.novelan.com...
Page 32
Novelan – an ait-deutschland GmbH brand Industriestraße 3 · 95359 Kasendorf info@novelan.com www.novelan.com We reserve the right to make technical change.
Need help?
Do you have a question about the LA Compact Station 1E and is the answer not in the manual?
Questions and answers