ENG | Instruction Manual
LK 450 EasyHeat P
TECHNICAL DATA
Voltage
Primary voltage, adapter
Max. boiler efficiency
Working temperature
Min. supply temperature
Max. supply temperature
Max. working pressure
Media
Thread standard
Circulating pumps
Sound level
Electrical connection
Protection type
Antifreeze function
Level guard
Expansion vessel
Overheating protection
File import / export
Weight
The LK 450 EasyHeat P 9kW is a complete portable electrically
heated boiler. It is primarily meant to be used as a temporary hea-
ter, e.g. for drying concrete slabs installed with under floor heating
and for heating buildings under construction. LK 450 EasyHeat
P (programmable) 9kW has possibilyity to make individual pro-
grams of a drying period. 60 individual heating steps enables full
control of the drying process and possibility to reciving a protocol
aftewards from a SD-card. In case of use as a temorary boiler
constant temp can be set.
EasyHeat comes in a blue aluminum cabinet with inspection
window, so you can monitor the unit during operation. Cabinet is
lockable by using a padlock.
With a Expansion tank of 6L EasyHeat is sutible för systems up to
125L. For bigger systems needs an external expansion vessel.
1
400 V
400 V
9kW (3 + 6kW)
8-60 °C
8 °C
60 °C
3 bar
Water - Glycol mixture max.
30%
G - female thread
Wilo Para 15/6 - Composite
<30 dB
CEE-socket 400V/16A 5-pole
IP44
Yes
Yes
6 l
80 °C
Micro SD-card (Max 32 GB)
<25 kg
www.lkarmatur.com
SAFETY INSTRUCTIONS
• Read the user manual before putting the product into operation.
• Safety instructions must be followed at all times.
• Modifications made to the product will void the warranty.
• LK Armatur disclaims all responsibility for damages caused by
the use of devices, accessories or spare parts not approved by the
manufacturer.
• Damage caused by substandard third-party components will
voids the warranty.
• Repair work on the product must be carried out by qualified
personnel.
• Make sure the device is placed on a flat surface free of obstacles.
• Hoses and cords must be placed in such a way that they do not
pose a risk of danger. In cases where this is not possible, attention
is drawn to hoses and cables with extra marking.
• External power supply must always be secured with a ground-
fault circuit breaker.
STORAGE OF UNIT
Store indoors, frost-free. Temperature 5-45 °C
• Relative humidity from 20 to 70%
DISCLAIMER
LK Armatur takes no responsibility for the program choices and
settings the user makes to achieve the intended heating purpose.
This product is designed to meet the requirements of the relevant
EC directives. To maintain this
status all installation, repair and maintenance must be carried out
by qualified personnel using only original spare parts.