ENG | Instruction Manual
LK 450 EasyHeat P
TECHNICAL DATA
Voltage
Primary voltage, adapter
Max. boiler efficiency
Working temperature
Min. supply temperature
Max. supply temperature
Max. working pressure
Media
Thread standard
Circulating pumps
Sound level
Electrical connection
Protection type
Antifreeze function
Level guard
Expansion vessel
Overheating protection
File import / export
Weight
The LK 450 EasyHeat P 9kW is a complete portable electrically
heated boiler. It is primarily meant to be used as a temporary hea-
ter, e.g. for drying concrete slabs installed with under floor heating
and for heating buildings under construction. LK 450 EasyHeat
P (programmable) 9kW has possibilyity to make individual pro-
grams of a drying period. 60 individual heating steps enables full
control of the drying process and possibility to reciving a protocol
aftewards from a SD-card. In case of use as a temorary boiler
constant temp can be set.
EasyHeat comes in a blue aluminum cabinet with inspection
window, so you can monitor the unit during operation. Cabinet is
lockable by using a padlock.
With a Expansion tank of 6L EasyHeat is sutible för systems up to
125L. For bigger systems needs an external expansion vessel.
1
400 V
400 V
9kW (3 + 6kW)
8-60 °C
8 °C
60 °C
3 bar
Water - Glycol mixture max.
30%
G - female thread
Wilo Para 15/6 - Composite
<30 dB
CEE-socket 400V/16A 5-pole
IP44
Yes
Yes
6 l
80 °C
Micro SD-card (Max 32 GB)
<25 kg
www.lkarmatur.com
SAFETY INSTRUCTIONS
• Read the user manual before putting the product into operation.
• Safety instructions must be followed at all times.
• Modifications made to the product will void the warranty.
• LK Armatur disclaims all responsibility for damages caused by
the use of devices, accessories or spare parts not approved by the
manufacturer.
• Damage caused by substandard third-party components will
voids the warranty.
• Repair work on the product must be carried out by qualified
personnel.
• Make sure the device is placed on a flat surface free of obstacles.
• Hoses and cords must be placed in such a way that they do not
pose a risk of danger. In cases where this is not possible, attention
is drawn to hoses and cables with extra marking.
• External power supply must always be secured with a ground-
fault circuit breaker.
STORAGE OF UNIT
Store indoors, frost-free. Temperature 5-45 °C
• Relative humidity from 20 to 70%
DISCLAIMER
LK Armatur takes no responsibility for the program choices and
settings the user makes to achieve the intended heating purpose.
This product is designed to meet the requirements of the relevant
EC directives. To maintain this
status all installation, repair and maintenance must be carried out
by qualified personnel using only original spare parts.

Advertisement

Table of Contents
loading

Summary of Contents for LK Armatur 450 EasyHeat P

  • Page 1 This product is designed to meet the requirements of the relevant The LK 450 EasyHeat P 9kW is a complete portable electrically EC directives. To maintain this heated boiler. It is primarily meant to be used as a temporary hea- status all installation, repair and maintenance must be carried out ter, e.g.
  • Page 2 ENG | Instruction Manual LK 450 EASY HEAT COMPRISES OF: Main power on/off 13. Manometer, 0-4 bar Display 14. Safety valve 3 bar Red light 15. Hose expansion vessel Green light 16. Hose filling valve Fuse PLC 17. Filling valve MIcro SD card reader 18.
  • Page 3: Installation

    ENG | Instruction Manual INSTALLATION START UP Before the unit is put into operation, it must be en- Connect to heating system by connecting to the unit’s supply sured that locally applicable building and hot water (from EasyHeat) and return (to EasyHeat) (Rotating nut 1”). installation standards are fulfilled.
  • Page 4: Shutdown And Storage

    ENG | Instruction Manual SHUTDOWN AND STORAGE When shutting down the unit. Stop the running heating program. Turn off pump. If heating data logging is applied, remember to export log file. Turn off main power swich and then disconnect power supply. Disconnect unit from heating system and make sure to empty out excess water.
  • Page 5 ENG | Instruction Manual LK 450 EASYHEAT DISPLAY STRUCTURE PROGRAM START SYSTEM SYSTEM SETTINGS PROGRAM SETTING CONSTANT ALARM CONSTANT SETTING Alarm indication • A blinking exclamation mark indicates active alarms in the device. • The number shows the quantity of active alarms. Buttons under the front cover Not used (service function) Not used (service function)
  • Page 6: Display: Alarm

    ENG | Instruction Manual DISPLAY: START SYSTEM DISPLAY: ALARM To get access to heating functions in display following settings Active Alarms. (Shows ongoing alarms) choices need to be done. Alarm history. (Alarms that have been but are no longer active) 1: Language ->...
  • Page 7: Function: Lamp

    ENG | Instruction Manual FUNCTION: POWER FAILURE / UNIT SHUTDOWN FUNCTION HEATING: PROGRAM (TEMP) The heating function regulates a 3 kW and a 6kW element that 1: If the unit detects that a power failure has accrued during active starts and stops based on how the water temperature relates to heating the Power Failure Alarm is activated to alert the fact that the setpoint temperature.
  • Page 8 ENG | Instruction Manual FUNCTION: ALARM FUNCTION: SD CARD, EXPORT/IMPORT PROGRAM Deviation alarm: If System temp and setpoint deviate 10+C for If needed program made in the display could be exported to the more than 3600sec. SD-Card or to the internal memory (as a backup) via function EX- PORT STEP PROGRAM in SET PROGRAM display.
  • Page 9: Technische Daten

    < 25 kg HAFTUNGSAUSSCHLUSS LK Armatur übernimmt keine Verantwortung für die Program- Die LK 450 EasyHeat P 9 kW ist eine vollständig, tragbare, elek- mauswahl und -einstellungen, die der Benutzer vornimmt, um den trische Heizung. Sie ist in erster Linie dafür konzipiert, als beabsichtigten Heizzweck zu erreichen.
  • Page 10 DE | Bedienungsanleitung DIE LK 450 EASY HEAT BESTEHT AUS: Netzschalter Ein/Aus 13. Manometer, 0 bis 4 bar Anzeige 14. Sicherheitsventil 3 bar Rote Leuchte 15. Schlauch Ausdehnungsgefäß Grüne Leuchte 16. Schlauch Füllventil Sicherung SPS 17. Füllventil MicroSD-Kartenleser 18. Rücklauf 1” Sicherungen 19.
  • Page 11 DE | Bedienungsanleitung START INSTALLATION Vor der Inbetriebnahme der Heizung ist sicherzus- Vor- und Rücklaufleitung mithilfe der 1-Zoll-Überwurfmut- tellen, dass die jeweils einschlägigen Standards tern an die Heizanlage anschließen. und Normen für den Hochbau und die Warmwas- Die Heizanlage muss mit Wasser befüllt und entlüftet sein. serinstallation eingehalten werden.
  • Page 12: Fehlerbehebung

    DE | Bedienungsanleitung HERUNTERFAHREN UND LAGERUNG Fehlerbeschreibung: Die Solltemperatur wird nicht erreicht! Heizung herunterfahren: Überprüfen, dass die Solltemperatur richtig eingestellt ist. Heizprogramm beenden. Pumpe ausstellen. Kann ein Fehler nicht behoben werden, bitte an den Kundendienst Falls Heizdaten aufgezeichnet werden, die Protokolldatei wenden.
  • Page 13 DE | Bedienungsanleitung LK 450 EASYHEAT MENÜSTRUKTUR SYSTEM PROGRAMM START SYSTEM PROGRAMM EINSTELLUNG EINSTELLUNGEN KONSTANT ALARM KONSTANT EINSTELLUNG Alarmanzeige • Ein blinkendes Ausrufezeichen zeigt aktive Alarme im Gerät an. • Die Zahl zeigt die Anzahl der aktiven Alarme an. Taster hinter der Frontabdeckung Nicht verwendet (Servicefunktion) Nicht verwendet (Servicefunktion) Nicht verwendet (Servicefunktion)
  • Page 14 DE | Bedienungsanleitung ANZEIGE: LAUFENDES PROGRAMM ANZEIGE: SYSTEM STARTEN 1: Sollwert. (Zeigt Solltemperatur für aktuellen Schritt) Zum Öffnen der Heizfunktionen in der Anzeige müssen folgende 2: Temperatur. (Zeigt Ist-Temperatur in der Anlage) Schritte unternommen werden. 3: Restzeit. (Zeigt Gesamtrestdauer im Programm) 1: Sprache ->...
  • Page 15 DE | Bedienungsanleitung FUNKTION: STROMAUSFALL / Heizung SCHALTET AB • Die Funktionalität dieses Alarms soll darauf hinweisen, dass 1: Falls die Heizung einen in der aktiven Heizphase aufgetretenen die Solltemperatur unter den aktuellen Bedingungen nicht Stromausfall erkennt, wird der Alarm für Stromausfall gesetzt, um erreicht wird.
  • Page 16 DE | Bedienungsanleitung FUNKTION: SD-KARTE, PROTOKOLLDATEI FUNKTION: WASSERPEGELERFASSUNG Bei der Ausführung eines Heizprogramms (Konstant oder Pro- Wasserpegelwert muss < 10 kΩ sein, damit die Heizfunktion aus- gramm Temp) wird eine Protokolldatei erstellt und im Geräte- geführt werden kann. Ein Wert > 10 kΩ zeigt an, dass KEIN Wasser speicher gespeichert.
  • Page 17 ENG | DE | FR | IT | FI | SE www.lkarmatur.se | www.lkarmatur.com | www.lkarmatur.de...
  • Page 18 ENG | DE | FR | IT | FI | SE ACCESSORIES & SPARE PARTS | ERSATZTEILE UND ZUBEHÖR | ACCESSOIRES & PIÈCES DÉTACHÉES | RICAMBI E ACCESSORI | VARAOSAT JA LISÄVARUSTEET | RESERVDELAR & TILLBEHÖR Article no. Article Position 187354 Wilo Para 15/6 - Composite 187352...
  • Page 19 ENG | DE | FR | IT | FI | SE www.lkarmatur.se | www.lkarmatur.com | www.lkarmatur.de...
  • Page 20 LK ARMATUR AB www.lkarmatur.com LK ARMATUR DEUTSCHLAND GMBH www.lkarmatur.de...

Table of Contents