31. Toggle the counterweight removal/install switch in the
cab to the OFF position.
32. Turn handle of stop valve (9) clockwise and ensure the
valve is completely closed.
33. Install top cover to the counterweight and three bottom
covers to the machine's mainframe.
34. Install cover (16) over the counterweight removal/install
operation lever.
35. Connect rear view camera connector (15).
36. Close pump compartment door.
COUNTERWEIGHT INSTALLATION
18
15
16
9
ZX470LC-5B
MJAA-NACW1-010
15
ZX670LC-5B
MJAA-NACW1-011
15
ZX870LC-5B
MJAA-NACW1-012
16
9
16
9