Download Print this page

Daikin RX09N5VL Service Manual page 21

Advertisement

Si001418E
Step
2
Remove the terminal
cover.
3
Remove the protection
bushing.
4
Disconnect the
compressor lead wires
and the overload
protector.
5
Remove the sheet of
putty.
6
Heat up and disconnect
the every brazed part of
the four way valve.
7
Remove the four way
valve.
Removal Procedure
Procedure
Terminal cover
W (blue)
U (red)
Protection
bushing
V (yellow)
Overload protector
(R20866)
(R20867)
Brazed part
Four way
valve
Putty
(R20868)
Four Way Valve
Points