Download Print this page

WEG EXP-IO- SENS-1000-ADV Instruction Manual

Advertisement

Quick Links

Instruction Manual
EXP-IO- SENS-1000-ADV
I/O Expansion card
• 2 PT1000 / NI1000 / Analog Inputs
• 1 Klixon / PTC / KTY84 Input
• 1 Klixon / PTC / KTY84 Output
2 Analog Outputs
Drive Requirements
The EXP-IO-SENS-1000-ADV card is designed for the following drives:
Drive Type: ADV200 WA (all versions); Recommended Firmware Release: 1.0 or later.
Drive Type: ADV200 (all versions); Firmware Release: 7.0 or later.
Description
The EXP-IO-SENS-1000-ADV is an optional expansion card for the ADV200 and ADV200 WA product family. This card
enables measurement of ambient temperature values via PT1000 or NI1000 external probe, and of motor temperatures via
Klixon, PTC or KTY84 external probe. The following I/O terminals are available on the card:
2 x Inputs for temperature measurement via PT1000 or NI1000 probe within the range of -20°C ÷ 150°C / -4°F ÷
302°F or alternately working as 2 x analog inputs for analog measurement (selection via software configuration)
1 x Input for temperature measurement via Klixon, PTC or KTY84 probe;
1 x Output for Klixon, PTC or KTY84 probe power supply;
2 x Analog Outputs.
About the Analog Outputs:
The analog outputs are manually configurable by means of a dedicated dip switch to select current or voltage
mode (see picture in the next paragraph);
The analog outputs can work in current mode within the range of 0 ÷ 20mA or in voltage mode within the range of
0 ÷ 10V.
NOTE
The drive can host one single card.
Connections
Card pinout details are shown below:
91
92
93
94
__________________________________________________________________________
95
96
97
98
EXP-IO-SENS-1000-ADV_EN
S2+
TMP
nu
51
52
53
54
61+
Cod. 1S5L37
Rev. 0.7 – 26-1-2023
61-
62+
62-
1

Advertisement

loading

Summary of Contents for WEG EXP-IO- SENS-1000-ADV

  • Page 1 Cod. 1S5L37 Rev. 0.7 – 26-1-2023 Instruction Manual EXP-IO- SENS-1000-ADV I/O Expansion card • 2 PT1000 / NI1000 / Analog Inputs • 1 Klixon / PTC / KTY84 Input • 1 Klixon / PTC / KTY84 Output • 2 Analog Outputs ...
  • Page 2 Terminal Name Function Max. DO NOT CONNECT CURRENT OR VOLTAGE SOURCE I-source Thermistor 1 Output current Thermistor 1 (max 11V@1.3mA) DO NOT CONNECT CURRENT OR VOLTAGE SOURCE V+ Thermistor 1 Positive Input Voltage Thermistor 1 (max 12V) DO NOT CONNECT CURRENT OR VOLTAGE SOURCE V- Thermistor 1 Negative Input Voltage Thermistor 1 (max 12V)
  • Page 3 Analog Output 1 and 2 dip-switches for voltage or current selection: Channel 1 analog output factory-configured for output 0 – 10V Channel 2 analog output factory-configured for output 0 – 10V __________________________________________________________________________ EXP-IO-SENS-1000-ADV_EN...
  • Page 4: Functional Block Diagram

     Functional Block Diagram Note: Terminals 92-93 and 96-97 can be used as ANALOG INPUT Terminals 51-52 and 53-54 can be used as TEMPERATURE SENSOR INPUT __________________________________________________________________________ EXP-IO-SENS-1000-ADV_EN...
  • Page 5  Probe Wiring Diagrams This section describes the wiring schema for connecting thermistors, RTD and sensors with reference to the most frequently used configuration. If the distance between the probe and the drive is longer than 3 meters (9.84 feet) 4-wire configuration is advisable.
  • Page 6 PT-1000 or NI1000 4-wire connection: • where Rw is the resistance of the wire and Rt is the resistance of the probe. Use two twisted pair shielded cables to connect the PT-1000/NI-1000 to the card and shortcut the shield to the metal cover of the drive (System Ground). Klixon / PTC / KTY84 connections: •...
  • Page 7: Installation

     Installation To install the card refer to the “Installation of optional cards” chapter in the “ADV200 WA & ADV200 Quick Start” installation handbook. This chapter describes the procedure for installing the card. During installation bear in mind the following: ...
  • Page 8: Ordering Information

     Ordering Information When ordering the EXP-IO-SENS-1000-ADV card please quote commercial code: S5L37. WEG Automation Europe S.r.l. Via Carducci, 24 - 21040 Gerenzano [VA] ITALY Ph. +39 02 967601 - Fax +39 02 9682653 - info.motion@weg.net - www.weg.net __________________________________________________________________________ EXP-IO-SENS-1000-ADV_EN...