Summary of Contents for Idemia SIGMA Series

  • Page 1 SIGMA Series Quick User Guide All descriptions illustrations, and specifications in this brochure should be considered approximate and may relate to optional equipment or feature...
  • Page 2 Table of Contents Color Step Content Overview Wiring Three Communications Four SDAC (Single Door Access Control) Five Software Administration Seven Capture basics 293732943-F IDEMIA DOCUMENT – REPRODUCTION AND DISCLOSURE PROHIBITED...
  • Page 3 (not displayed HID® iCLASS™ 13,56MHz (SIGMA … ICLASS) here) Or MIFARE™ DESFire ™ 13,56MHz (SIGMA .. MULTI) Optical biometrical sensor Or HID® Prox ® 125kHz (SIGMA .. PROX) 293732943-F IDEMIA DOCUMENT – REPRODUCTION AND DISCLOSURE PROHIBITED...
  • Page 4 Use only Brand Name cards. No name card may have lower performances or lower life time. Electronic documentation is provided in Adobe® Acrobat® format (PDF). Adobe® Acrobat® Reader is available at http://www.adobe.com. 293732943-F IDEMIA DOCUMENT – REPRODUCTION AND DISCLOSURE PROHIBITED...
  • Page 5 SIGMA Series The SIGMA Series contains the following product variants: Contactless Smart card reader ® Biometrics MIFARE Water ® ® Product designation iCLASS Prox ® (Fingerprint) DESFire Resistant (*)   SIGMA    SIGMA iClass   ...
  • Page 6 SIGMA terminal implementation To secure an access, IDEMIA recommends installing the SIGMA Series terminal as a part of a typical Access Control system, this consists of the components described below. The SIGMA Series terminal Its role is to process the access request from the user. It performs access right checks using one-to-many biometric identification or one-to-one biometric verification, and/or RF card authentication, and/or PIN check.
  • Page 7 (2) stored on the contactless card or in the user record in the terminal’s local database (3) There is no fingerprint image stored in the terminal, but only points of interest (minutiae) of each fingerprint 293732943-F IDEMIA DOCUMENT – REPRODUCTION AND DISCLOSURE PROHIBITED...
  • Page 8 High humidity, direct sun exposure, frequent high temperature, outdoor careless uses may alter the durability of the terminal.  When the terminal is exposed to such potential extreme conditions, IDEMIA recommends deploying an enclosure to protect the terminal and thus ensure a long-lasting performance in the field. 293732943-F...
  • Page 9: Wiring Overview

    Backup of the Date/Time of the terminal: the volatile settings (such as date/time) of the terminal are protected against power failure, by a dedicated component during a least 24 hours (at 25 C) without external power supply. 293732943-F IDEMIA DOCUMENT – REPRODUCTION AND DISCLOSURE PROHIBITED...
  • Page 10: Power Wiring

    This feature requires a specific electronic card plugged at the rear of the product. Warning: after use, the temperature of the POE module may be high: after power cut off, wait 5mn before working on connectors area. IDEMIA recommends using a gauge AWG20 for 12V power supply. Maximum voltage drop Gauge...
  • Page 11 A maximum of 31 devices may be installed on the same line. The maximum total cable length is 4000 ft. (1200m). The cable must be dedicated to this installation and not used for any other purpose 293732943-F IDEMIA DOCUMENT – REPRODUCTION AND DISCLOSURE PROHIBITED...
  • Page 12 Use CAT-5 UTP (or better) cable (shielded recommended) with a impedance of 120 . AWG 24 should be the minimum wire gauge used. The maximum total cable length is 4000 ft. (1200m). The cable must be dedicated to this installation and not used for any other purpose 293732943-F IDEMIA DOCUMENT – REPRODUCTION AND DISCLOSURE PROHIBITED...
  • Page 13  Use a category 5 shielding cable (120 Ohms) or better. It is strongly recommended to insert a repeater unit every 90m.  By default, SIGMA Series terminal is configured in Static IP mode. LAN Ethernet Management station IP address...
  • Page 14 For 18 AWG, the maximum cable distance is 500 ft. (150m); for 20 AWG, the maximum is 300 ft. (90m); for 22 AWG, the maximum is 200 ft. (60m). Electrical interface conforms to the Security Industry Association's Wiegand standard March 1995, and it is 5V TTL compatible. 293732943-F IDEMIA DOCUMENT – REPRODUCTION AND DISCLOSURE PROHIBITED...
  • Page 15 Data Clock In Data WIEGAND_IN0 Green / Red Clock WIEGAND_IN1 White / Red WIEGAND_GND Black / Red Data WIEGAND_OUT0 Green Clock WIEGAND_OUT1 White Data Clock Out WIEGAND_LEDOUT1 Blue LED Out WIEGAND_LEDOUT2 Blue / Red 293732943-F IDEMIA DOCUMENT – REPRODUCTION AND DISCLOSURE PROHIBITED...
  • Page 16 If door contact is not used, GPI1 (Orange / Red wire) and GPO1 (Yellow / Red wire) shall be connected together • Power supply from electrical source shall be switched off before starting the installation. 293732943-F IDEMIA DOCUMENT – REPRODUCTION AND DISCLOSURE PROHIBITED...
  • Page 17 2A, damage to the device may occur. If the deadbolt / door strike load exceeds 2A, an external relay must be used.  The internal relay is designed for 100.000 cycles. If more cycles are needed, an external relay driven by GPO must be used. 293732943-F IDEMIA DOCUMENT – REPRODUCTION AND DISCLOSURE PROHIBITED...
  • Page 18 Software for Remote Administration and Enrollment Terminals are compatible with MorphoManager application, version 15.5 or higher 293732943-F IDEMIA DOCUMENT – REPRODUCTION AND DISCLOSURE PROHIBITED...
  • Page 19 Boot assistant at next boot: Display this screen on next boot. Protocol Settings: select communication protocol : Bioscrypt 4G terminals, MA 500 and J Series (MA2G), or MorphoAccess SIGMA (MA5G) 293732943-F IDEMIA DOCUMENT – REPRODUCTION AND DISCLOSURE PROHIBITED...
  • Page 20 Configuration with a script hosted on a USB dongle not possible The default configuration is recommended by IDEMIA for operations. To use the features non available by default, the On-demand security state can be unlocked with MorphoBioToolBox. This shall not be done unless the end customer is made aware and an assessment on the system security is done.
  • Page 21 This Windows application can also be used for the full terminal configuration. Starting from version 16, MorphoManager can also configure the TLS communication of a terminal as soon as the latter has a valid IP address. 293732943-F IDEMIA DOCUMENT – REPRODUCTION AND DISCLOSURE PROHIBITED...
  • Page 22 Optionnally, a contactless card can be created. “Local enrollment” shall not be used in a secure system, where it should be performed on an enrolment station (a PC with a dedicated application such as MorphoManager). 293732943-F IDEMIA DOCUMENT – REPRODUCTION AND DISCLOSURE PROHIBITED...
  • Page 23 /or warm it up. ergonomically more difficult to use) figure above. For handling large scale enrollments please contact your IDEMIA representative for training and services options 293732943-F IDEMIA DOCUMENT – REPRODUCTION AND DISCLOSURE PROHIBITED...
  • Page 24 Incorrect Position: • Do not tilt the finger to the right or left side of the sensor Finger Angle Correct Position: • The finger must be parallel to sensor sides IDEAL POSITION 293732943-F IDEMIA DOCUMENT – REPRODUCTION AND DISCLOSURE PROHIBITED...
  • Page 25 Inclination Correct Position: • Finger is parallel to sensor surface IDEAL POSITION Incorrect Position: • Do not roll finger Finger rotation Correct Position: • Finger is parallel to surface sensor IDEAL POSITION 293732943-F IDEMIA DOCUMENT – REPRODUCTION AND DISCLOSURE PROHIBITED...
  • Page 26 LCD touch screen The terminal reads the user data stored in the card (at depending on the configuration. least the User ID), and starts the authentication process, as defined by the terminal settings 293732943-F IDEMIA DOCUMENT – REPRODUCTION AND DISCLOSURE PROHIBITED...
  • Page 27 Use dry air spray to remove the dust out of the sensor glass Firmware release  To get the best of our technology, we recommend you to download and install the last firmware release (please refer to last page) 293732943-F IDEMIA DOCUMENT – REPRODUCTION AND DISCLOSURE PROHIBITED...
  • Page 28 Release note : for each firmware version, a release note is published describing the new features, the supported products, the potential known issues, the upgrade / downgrade limitations, the recommendations, the potential restrictions… 293732943-F IDEMIA DOCUMENT – REPRODUCTION AND DISCLOSURE PROHIBITED...
  • Page 29 Copyright © 2022, IDEMIA. All rights reserved. www.idemia.com Reproduction in whole or in part in any form or medium without the express written permission of IDEMIA is prohibited. The trademarks identified herein are the trademarks of registered trademarks of IDEMIA, or other third party.