Technical features
Fluid: Compressed air
Maximum pressure:
Guarded transparent bowl: 10 bar (150 psig)
Metal bowl: 17 bar (250 psig)
Operating temperature*:
Transparent bowl: –20° ... +50°C (0° ... +125°F)
Metal bowl: –20° ... +80°C (0° ... +175°F)
* Air supply must be dry enough to avoid ice forma-
tion at temperatures below +2°C (+35°F).
Particle removal: 5 µm, 25 µm or 40 µm filter element
Air quality: Within ISO 8573-1, Class 3 and Class 5
(particulates)
Typical flow with 40 µm element, 6,3 bar (90 psig)
inlet pressure and 0,5 bar (7 psig) droop from set: 70
dm
/s (148 scfm)
3
Automatic drain connection: 1/8"
Automatic drain operating conditions:
Pressure: 0,7 bar (10 psig). Drain opens when bowl
pressure drops below 0,2 bar (3 psig).
Minimum air flow: 1 dm
/s (2 scfm) required to close
3
drain
Nominal bowl size: 0,2 litre (7 fluid oz)
Materials:
Body: Zinc
Bowl:
Metal: Aluminium
Transparent, optional: Polycarbonate
Metal bowl liquid level indicator lens, standard:
Grilamid
Metal bowl sight glass, optional: Pyrex
Element: Sintered plastic
Elastomers: Synthetic rubber
Replacement Items
Service kit, contains required items circled:
Prismatic sight glass
Pyrex sight glass
Filter element, 5 µm
Filter element, 40 µm
Manual drain
Automatic drain
Mechanical service Indicator (1)
Installation
1. Install unit vertically in air line -
• vertically (bowl down),
• with air flow in direction of arrow on body,
• upstream of regulators, lubricators, and cycling valves,
• as close as possible to the air supply when used as a
main line filter,
• as close as possible to the device being serviced
when used as a final filter.
2. Before assembling the basic unit into the yoke the port
seal o-rings should be lightly smeared with o-ring grease.
3. Locate clamp ring under lugs on top of yoke, offer basic
unit into yoke with directional arrows correctly aligned
(an interference fit prevents assembly if misaligned)
before engaging and fully tightening the clamp ring.
Option
D
Service indicator
N
None
Drain
A
M
Q
4. Turn bowl or bowl guard fully clockwise into
body before pressurizing. Lock symbols on
body and bowl guards must align.
5. Auto-drain units may be fitted with a short
drain pipe and connector, minimum 5 mm
bore, to the G1⁄8 bottom outlet.
Servicing
1. Open manual drain to expel accumulated
liquids. Keep liquids below baffle (53).
2. To operate automatic drain manually, lift
operating pin in bottom outlet with a blunt
rod.
3. Clean or replace filter element when dirty.
Disassembly
1. Shut off inlet pressure. Reduce pressure in
inlet and outlet lines to zero.
2. For ease of maintenance the unit can be re moved
from the yoke by unscrewing the clamp ring, which
will jack the unit out downwards.
3. Lift and turn the filter bow counterclockwise and
remove with bowl o-ring.
4. Disassemble in general accordance with the item
numbers on exploded view. Do not remove the drains
or the service indicator unless replacement is neces-
sary. Remove and replace only if they malfunction.
Cleaning
4380-200
1. Partial cleaning of the filter element is possible
4380-040
by washing the element in soapy water and blow-
4380-041
ing out thoroughly with compressed air. Replace-
4338-01
ment by a clean element is
4338-02
recommended. Clean plastic bowl and lens (45)
684-84
with warm water only. Clean other parts with
3000-97
warm water and soap.
5797-50
2. Rinse and dry parts. Blow out internal passages in
body with clean, dry compressed air.
3. Inspect parts. Replace those found to be damaged.
Replace plastic bowl with a metal bowl if plastic
bowl shows signs of cracking or cloudiness.
Assembly
1. Lubricate o-rings with o-ring grease.
2. Assemble the unit as shown on the exploded view.
3. Torque Table
Item
55 (Filter guide) 2,0 ... 2,7 max
4. Assemble baffle (53), contact + 1/4 turn.
5. Turn bowl or bowl with guard fully clockwise
into body.
Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document. (1999 - I&M8074d) © 2020 IMI International s.r.o.
F64G – ˙˙˙ – ˙˙˙
Bowl
D
P
R
Automatic
Manual
Manual 1/4 turn
A
B
C
Torque in
N-m
(Inch-Pounds)
(18 ... 25)
Installation & Maintenance Instructions
Metal
Transparent with guard
Metal with Pyrex sight glass
Caution
Water vapor will pass through these units and could
condense into liquid form downstream as air temper-
ature drops. Install an air dryer if water condensation
could have a detrimental effect on the application.
6
7
56
55
54
53
18
26
19
22
25
28
21
24
27
20
23
32
40
33
36
39
42
35
38
41
34
37
I&M/en 8.240.100.01
F64G Filter
Element
1
5 µm
2
25 µm
3
40 µm
1
2
4
3
5
8
31
30
29
47
48
46
45
44
43
01/22

Advertisement

loading

Summary of Contents for IMI NORGREN F64G

  • Page 1 Our policy is one of continued research and development. We therefore reserve the right to amend, 01/22 without notice, the specifications given in this document. (1999 - I&M8074d) © 2020 IMI International s.r.o. I&M/en 8.240.100.01...
  • Page 2 Norgren. Our policy is one of continued research and development. We therefore reserve the right to amend, I&M/en 8.240.100.02 without notice, the specifications given in this document. (1999 - I&M8074d) © 2020 IMI International s.r.o. 01/22...