Technical Data
Fluid: Compressed air
Metal bowl: 17 bar (250 psig)
Transparent bowl: 10 bar (150 psig
Operating temperature*:
Metal bowl: –20° ... +65°C (0° ... +150°F)
Transparent bowl: –20° ... +50°C (0° ... +125°F)
* Air supply must be dry enough to avoid ice forma-
tion at temperatures below +2°C (+35°F).
Integral F64B/L Pre- ilter Element: 40 µm
nominal
Particle Removal F64B/L: 0,01 µm
Maximum Remaining Oil Content:
0,003 mg/m3 at +21°C (+70°F)
Air Quality: Within ISO8573-1:2010: 1:7:0
Typical performance characteristics
Inlet pressure
Maximum low (dm
(bar)
F64B
1
6,7
3
10,7
5
13,8
6,3
15,6
7
16,5
9
18,8
* Maximum low to maintain stated oil removal
performance.
Automatic drain connection: 1/8"
Automatic drain operating conditions:
Bowl pressure required to close drain:
Greater than 0,3 bar (5 psig)
Bowl pressure required to open drain:
Less than 0,2 bar (3 psig)
Minimum air low required to close drain:
1 dm3/s (2 scfm)
Manual operation: Depress pin inside drain
outlet to drain bowl
Nominal bowl size: 0,2 litre (7 luid oz)
Materials:
Body: Zinc
Bowl:
Metal: Zinc
Transparent: Polycarbonate
Metal bowl sight glass, standard: Pyrex
Element: Composite materials
Elastomers: Synthetic rubber
F64˙ – ˙˙N – ˙˙0
Thread
A
PTF
B
ISO Rc tapered
G
ISO G parallel
N
No yoke
Replacement Items
Service Kit
(Item No. (s) 3, 5, 8, 9, 14, 16, 17, 18, 20):
F64B-
F64L-
Pyrex sight glass kit (Item No. 7)
Element, coalescing (Item No. 3):
F64B
F64L
Element, integral pre- ilter
(Item No. 16)
Activated carbon pack
(Item No. 18)
Manual drain (Item No. 9, 12, 13, 14) 684-84
Automatic drain (Item No. 8)
Automatic drain - USA only
(Item No. 8)
/s) *
3
F64L
Operation
7,1
On exceptionally dirty lines it may be neces-
11,3
sary to clean the pre- ilter element at 90 day
14,4
intervals.
16,3
Do not exceed Maximum Flow rating or
excessive pressure drop will result or oil carry
17,2
over may occur.
19,5
The top ilter element acts as absorbant
pack to remove any small traces of oil or
hydro-carbon gases which might
be carried over from the lower bowl.
These elements also provide protection in the
event of any failure of the lower ilter.
Resistance to air low will gradually increase
as the ilter element collects solid particles.
The pressure differential across the element
should not be allowed to exceed 0,7 bar
(10 psi) or damage to the element may
occur.
Servicing
Air Service equipment should be initially
maintained annually. Use, quality of air and
condition at examination may indicate ad-
justment of the maintenance interval.
1. Open manual drain to expel accumulated
liquids. Keep liquids below element (3).
2. To operate automatic drain manually, lift
operating pin in bottom outlet with a blunt
rod.
3. Clean or replace ilter element when dirty.
Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the speci ications given in this document. (1999-xxxxb) © 2020 IMI International s.r.o.
F64B, F64L - Ultra High Ef iciency Coalescing Filter
Installation & Maintenance Instructions
Drain
A
Automatic
M
Manual
Bowl
R
T
F64B-KITA0V
F64L-KITA0V
2273-97
5350-99
5350-98
3698-02
20
5568-02
1
6000-70
4
3000-70
14
5
12
14
7
10
9
13
21
5
8
14
7
10
9
Metal with Pyrex sight glass
Transparent
21
15
18
18
17
20
1
2
2
5
16
16
12
14
19
6
3
19
3
3
3
10
9
13
5
8
14
10
9
IM/en 8.240.115.001
4
15
17
28
37
05/21

Advertisement

loading

Summary of Contents for IMI NORGREN F64B Series

  • Page 1 3. Clean or replace ilter element when dirty. Our policy is one of continued research and development. We therefore reserve the right to amend, 05/21 IM/en 8.240.115.001 without notice, the speci ications given in this document. (1999-xxxxb) © 2020 IMI International s.r.o.
  • Page 2 Our policy is one of continued research and development. We therefore reserve the right to amend, IM/en 8.240.115.002 without notice, the speci ications given in this document. (1999-xxxxb) © 2020 IMI International s.r.o. 05/21...

This manual is also suitable for:

Norgren f64l series