  • Page 1 Wired Controller IOM - VMHxxDU WIRED CONTROLLER INSTALLATION AND OWNER’S MANUAL Model KJR-120G1/TFBG-E-01 KJR-120G2/TFBG-E-03 517.787.2100 • www.marsdelivers.com...
  • Page 2 Wired Controller IOM - VMHxxDU ● This manual gives detailed description of the precautions that should be brought to your attention during operation. ● To ensure the correct service of the wired controller, read this manual carefully before using the unit. ●...
  • Page 3: Table Of Contents

    Wired Controller IOM - VMHxxDU 1. SAFETY PRECAUTION....................1 2. INSTALLATION ACCESSORY..................2 3. INSTALLATION METHOD....................4 4. APPENDIX INSTALL THE WIRE CONTROLLER KIT..........11 5. SPECIFICATION......................17 6. WIRED CONTROLLER FEATURES AND FUNCTIONS..........18 7. WIRED CONTROLLER DISPLAY.................19 8. WIRED CONTROLLER BUTTONS................20 9. PREPARATORY OPERATION..................21 10.
  • Page 4: Safety Precaution

    Wired Controller IOM - VMHxxDU 1. SAFETY PRECAUTION Read the safety precautions carefully before installing the unit.  Stated below are important safety issues that must be obeyed.  Means improper handling may lead to personal death or severe injury. WARNING Means improper handling may lead to personal injury or property loss.
  • Page 5: Installation Accessory

    Wired Controller IOM - VMHxxDU 2. INSTALLATION ACCESSORY S S e e l l e e c c t t t t h h e e i i n n s s t t a a l l l l a a t t i i o o n n l l o o c c a a t t i i o o n n D D o o n n ’...
  • Page 6 Wired Controller IOM - VMHxxDU 2. INSTALLATION ACCESSORY WIRED CONTROLLER INSTALLATION PRECAUTION 1 1 . . T T h h i i s s m m a a n n u u a a l l p p r r o o v v i i d d e e s s t t h h e e w w i i r r e e d d c c o o n n t t r r o o l l l l e e r r i i n n s s t t a a l l l l a a t t i i o o n n m m e e t t h h o o d d . . R R e e f f e e r r t t o o t t h h e e w w i i r r i i n n g g d d i i a a g g r r a a m m i i n n t t h h i i s s i i n n s s t t a a l l l l a a t t i i o o n n m m a a n n u u a a l l t t o o w w i i r r e e t t h h e e w w i i r r e e d d c c o o n n t t r r o o l l l l e e r r w w i i t t h h t t h h e e i i n n d d o o o o r r u u n n i i t t .
  • Page 7: Installation Method

    Wired Controller IOM - VMHxxDU 3. INSTALLATION METHOD 1.Wired Remote Controller Dimensions (4.7”) (0.7”) (1.8”) (4.8”) (3.3”) (2.4”) Fig 3-1 2.Wiring Connection Diagram Insert of the mainboard CN40 ----------------------------------- black black ----------------------------------- yellow yellow ----------------------------------- brown brown ----------------------------------- 4-Core Shield Cable, the length Wired controller Indoor unit mainboard is decided by installation...
  • Page 8 Wired Controller IOM - VMHxxDU 3. INSTALLATION METHOD 3.Wiring figure Mainboard 4-core shielding wire The connection cable CN40 Fig 3-3(A) Model :KJR-120G2/TFBG-E-03(12V) C C o o n n n n e e c c t t t t h h e e f f e e m m a a l l e e j j o o i i n n t t o o f f t t h h e e w w i i r r e e s s g g r r o o u u p p f f r r o o m m t t h h e e m m a a i i n n b b o o a a r r d d w w i i t t h h t t h h e e m m a a l l e e j j o o i i n n t t o o f f t t h h e e c c o o n n n n e e c c t t i i v v e e w w i i r r e e s s g g r r o o u u p p .
  • Page 9 Wired Controller IOM - VMHxxDU 3. INSTALLATION METHOD Display board Adapter board The connection CN101 cable 4-core shielding wire Model B:KJR-120G1/TFBG-E-01(5V) Fig 3-3(B) I I n n s s t t a a l l l l t t h h e e A A d d a a p p t t e e r r B B o o a a r r d d a a n n d d t t h h e e D D i i s s p p l l a a y y B B o o a a r r d d o o n n t t h h e e H H i i g g h h W W a a l l l l ( ( S S e e e e t t h h e e A A p p p p e e n n d d i i x x f f o o r r i i n n s s t t r r u u c c t t i i o o n n s s ) ) .
  • Page 10 Wired Controller IOM - VMHxxDU 3. INSTALLATION METHOD 4.Wired controller upper part Remove I I n n s s e e r r t t a a f f l l a a t t s s c c r r e e w w d d r r i i v v e e r r i i n n t t o o t t h h e e s s l l o o t t s s i i n n t t h h e e l l o o w w e e r r p p a a r r t t o o f f t t h h e e w w i i r r e e d d c c o o n n t t r r o o l l l l e e r r ( ( 2 2 p p l l a a c c e e s s ) ) .
  • Page 11 Wired Controller IOM - VMHxxDU 3. INSTALLATION METHOD For switch box mounting, fasten the back plate on the switch box with 2 screws (M4x25) and fasten it on the wall with 1 screw (ST3.9x25). (Fig.3-6) Back plate Switch box Screw (ST3.9×25) Screws (M4×25) Fig 3-6 N N O O T T E E : : P P l l a a c c e e o o n n a a f f l l a a t t s s u u r r f f a a c c e e .
  • Page 12 Wired Controller IOM - VMHxxDU 3. INSTALLATION METHOD 7. Wire the indoor unit There are three methods: 1 from the rear; 2 from the bottom; 3 from the top; 4. Notch the part for the wiring to pass through with a nipper tool.
  • Page 13: D D

    Wired Controller IOM - VMHxxDU 3. INSTALLATION METHOD NOTE: DO NOT allow water to enter the remote control. Use the trap and putty to seal the wires. Putty Trap Putty Putty Trap Trap Fig 3-8 8 8 . . R R e e a a t t t t a a c c h h t t h h e e w w i i r r e e d d c c o o n n t t r r o o l l l l e e r r ’ ’ s s u u p p p p e e r r p p a a r r t t While adjusting and mounting the upper case, avoid clamping the wiring during installation.
  • Page 14: Appendix Install The Wire Controller Kit

    Wired Controller IOM - VMHxxDU 4. APPENDIX INSTALL THE WIRED CONTROLLER KIT 1. Open the front panel. 2. Disconnect the wire from the main controller board.
  • Page 15 Wired Controller IOM - VMHxxDU 4. APPENDIX INSTALL THE WIRED CONTROLLER KIT 3. Identify the components. From left to right, the wired controller, convert board and the display board. 4. Identify connections on the Display Board. CN201 is the display board connection to the main board wire (on the display board).
  • Page 16 Wired Controller IOM - VMHxxDU 4. APPENDIX INSTALL THE WIRED CONTROLLER KIT CN101 is the display board connection to the convert board wire (on the display board). 5. Uninstall the display board from the front panel. Keep the display board holder.
  • Page 17 Wired Controller IOM - VMHxxDU 4. APPENDIX INSTALL THE WIRED CONTROLLER KIT 6. Carefully bend and break off the rectangular section (upper left section with two diagonal holes) from the display board. NOTE: Break off the upper left hand rectangle (section with the two holes marked with a red rectangle).
  • Page 18 Wired Controller IOM - VMHxxDU 4. APPENDIX INSTALL THE WIRED CONTROLLER KIT 8. Before assembling mounting back on the Front Panel, remove the display board’s screen cover. 9. Connect the Wires to the Adaptor Board. a. Connect the wire coming from the Display board to the Convert Board (this connection consists of 5 wires).
  • Page 19 Wired Controller IOM - VMHxxDU 4. APPENDIX INSTALL THE WIRED CONTROLLER KIT b. Connect the wire coming from the Wired Remote Controller to the Convert Board (this connection consists of 4 wires). 10. Once the ports are connected, install the cover. 11.
  • Page 20: Specification

    Wired Controller IOM - VMHxxDU 5. SPECIFICATION DC 5V/DC 12V Input voltage Ambient temperature 23~110℉(-5~43℃) RH40%~RH90% Ambient humidity Wiring specifications Wiring type Total length Size <66 ft (20m) 0.029 in-0.74mm Shielded vinyl cord or cable (0.75-1.25mm ) <164 ft (50m)
  • Page 21: Wired Controller Features And Functions

    Wired Controller IOM - VMHxxDU 6. FEATURE AND FUNCTION OF THE WIRED CONTROLLER Feature: LCD display. Malfunction code display: displays the error code (helpful for servicing) 4-way wire layout design. Room temperature display. Copy/ Swing Timer Day off/Del Confirm Back/Turbo Follow me ℃...
  • Page 22: Wired Controller Display

    Wired Controller IOM - VMHxxDU 7. WIRED CONTROLLER DISPLAY 1. Operation mode indicator 8. Turbo/Auxiliary Heat function indicator 2. Fan speed indicator 9. °C / °F indicator 3. Left-right swing indicator 10. Temperature display 4. Up-down swing indicator 11. Lock indicator 5.
  • Page 23: Wired Controller Buttons

    Wired Controller IOM - VMHxxDU 8. WIRED CONTROLLER BUTTONS Copy/ Swing Timer Day off/Del Confirm Back/Turbo Follow me Mode Fan speed (Lock) 1. Mode 6. Timer 2. Power 7. Day Off/Del 3. Adjust 8. Copy/Follow me 4. Fan Speed 9. Back/Turbo 5.
  • Page 24: Preparatory Operation

    Wired Controller IOM - VMHxxDU 9. PREPARATORY OPERATION Set the current day and time Press TIMER for 3s or more. The timer displays flashes. Timer Press + or − to set the date. The selected date flashes. Date setting is complete and the time setting is ready Timer after pressing TIMER or if nothing is pressed in 10 seconds.
  • Page 25: Operation

    Wired Controller IOM - VMHxxDU 10. OPERATION To start/stop operation Press the Power button. To set the operation mode Operation mode setting Press MODE to set the operation mode. Mode (Heat function is invalid for cool only type unit) Room temperature setting Press + or −...
  • Page 26 Wired Controller IOM - VMHxxDU 10. OPERATION Fan speed setting Press FAN SPEED to set the fan speed NOTE: This function is unavailable in the AUTO or DRY modes. Fan speed (Lock) Room temperature sensor selection Press FOLLOW ME to select whether the room temperature is detected at the indoor unit or at the wired controller.
  • Page 27 Wired Controller IOM - VMHxxDU 10. OPERATION Child lock function Press LOCK for 3 seconds to activate the CHILD LOCK feature and lock all buttons on the wired controller. Press again for 3 seconds Fan speed to deactivate. (Lock) NOTE: When the child lock function is activated, lock image appears.
  • Page 28 Wired Controller IOM - VMHxxDU 10. OPERATION Turbo/Auxiliary Heat function (on some models) • Press TURBO to activate/deactivate the Turbo/Auxiliary Back/Turbo Heat function. The turbo function sets the unit to reach the user’s present temperature in the shortest amount of time possible.
  • Page 29 Wired Controller IOM - VMHxxDU 10. OPERATION Swing function (For the unit with left & right auto swing function only) 1 Up-Down swing Swing Press the Swing button to start up-down swing function. Press it again to stop. When the Up-Down swing function is activated,the mark appears.
  • Page 30 Wired Controller IOM - VMHxxDU 10. OPERATION Swing function (For the unit without left & right auto swing function models) Up-Down airflow direction and swing Swing Use SWING to adjust the up and down airflow direction. 1.Every time the user presses SWING, the louver swings six degrees. 2.Press and hold SWING for 2 seconds, it changes to the UP−DOWN SWING mode.
  • Page 31: Timer Functions

    Wired Controller IOM - VMHxxDU 11. TIMER FUNCTIONS WEEKLY timer Use to set the operating times for each day of the week. On timer Use to start the air conditioner operation. The timer operates and the air conditioner operation starts after the time has passed. Off timer Use to stop the air conditioner operation.
  • Page 32 Wired Controller IOM - VMHxxDU 11. TIMER FUNCTIONS To set the On or Off TIMER Press Timer to select the Timer No display Press Confirm and the Clock display flashes Confirm ex.Off timer set at PM 6:00 Press + or − to set the time. After the time is set, the timer starts or stops automatically.
  • Page 33 Wired Controller IOM - VMHxxDU 11. TIMER FUNCTIONS To set the On and Off TIMER Press Timer to select the Timer Confirm Press Confirm and the Clock display flashes. Confirm Press the button + or - to set the On timer and then press Confirm.
  • Page 34: Weekly Timer

    Wired Controller IOM - VMHxxDU 12. WEEKLY TIMER Weekly timer setting Press Timer to select the and press Confirm. Confirm Timer Day of the week setting Press + or − to select the day of the week Confirm and then press CONFIRM. ON timer setting of timer setting 1 Press + and −...
  • Page 35 Wired Controller IOM - VMHxxDU 12. WEEKLY TIMER IMPORTANT: Up to 8 scheduled events can be set on one day. Various events can be scheduled in either MODE, TEMPERATURE and FAN speeds. ex.Tuesday time scale 1 Time setting Press + and − to set the time then press Confirm CONFIRM.
  • Page 36 Wired Controller IOM - VMHxxDU 12. WEEKLY TIMER Fan speed setting Press + and − to set the fan speed then press Confirm CONFIRM. NOTE: This setting is unavailable in the AUTO, DRY or OFF modes. Different scheduled events can be set by repeating steps 3 through 7.
  • Page 37 Wired Controller IOM - VMHxxDU 12. WEEKLY TIMER WEEKLY timer operation To start Press Timer to select the , and then the timer Timer starts automatically. To cancel Press Power to cancel the timer mode. The timer mode can also be canceled by changing the Timer timer mode using Timer.
  • Page 38 Wired Controller IOM - VMHxxDU 12. WEEKLY TIMER Press DAY OFF to create an off day. Day off/Del mark is hidden ex.The DAY OFF is set for Wednesday Set the DAY OFF for other days by repeating the steps 2 and 3. Back/Turbo Press BACK to revert to the weekly timer.
  • Page 39 Wired Controller IOM - VMHxxDU 12. WEEKLY TIMER Copy/ Press COPY, the letters CY appear on the LCD. Follow me Press + or − to select the day to copy to. Press COPY to confirm. Copy/ Follow me mark flashes quickly ex.
  • Page 40 Wired Controller IOM - VMHxxDU 12. WEEKLY TIMER Delete the time scale in one day. During the weekly timer setting, Confirm press CONFIRM. Press + and − to select the day of the week Confirm and then press CONFIRM. Day off/Del Press + and −...
  • Page 41: Set External Static Pressure

    Wired Controller IOM - VMHxxDU 13. SET EXTERNAL STATIC PRESSURE Using the wired controller to set external static pressure (some air conditioners) . • You can use the unit’s automatic airflow adjustment function to set external static pressure. • Automatic airflow adjustment is the volume of blow-off air that has been automatically adjusted to the quantity rated.
  • Page 42: Fault Alarm Handl L Ing

    Wired Controller IOM - VMHxxDU 14. FAULT ALARM HANDING If the system does not properly operate except in the aforementioned cases or the aforementioned malfunctions are evident, investigate the system according to the following procedures. DISPLAY MALFUNCTION AND PROTECTION DEFINITION DIGITAL TUBE Communication error between wired controller and indoor unit...
  • Page 43 Wired Controller IOM - VMHxxDU Page Intentionally Left Blank...