STIEBEL ELTRON EASYTRON Connect Operation And Installation Manual

STIEBEL ELTRON EASYTRON Connect Operation And Installation Manual

Individual room control

Advertisement

Quick Links

OPERATION AND INSTALLATION
Individual room control
» EASYTRON Connect

Advertisement

Table of Contents
loading

Summary of Contents for STIEBEL ELTRON EASYTRON Connect

  • Page 1 OPERATION AND INSTALLATION Individual room control » EASYTRON Connect...
  • Page 2: Table Of Contents

    EASYTRON Connect room temperature sensor ERT ����� 20 Troubleshooting �������������������������������������������� 11 13.3 EASYTRON Connect radiator actuator ERS ���������������� 22 Status display for EASYTRON Connect base station EZE 11 13.4 Completing the connection of wireless components ���� 23 Status display for the EASYTRON Connect radiator Settings �����������������������������������������������������...
  • Page 3: Operation

    General information OpERATiON 15.2 Connection test on the wireless components ������������� 24 15.3 Failed connection to the EASYTRON Connect base station EZE ������������������������������������������������������� 26 15.4 EASYTRON Connect repeater ERE ��������������������������� 26 15.5 Resetting wireless components to the factory setting �� 27 General information Appliance shutdown ���������������������������������������...
  • Page 4: Other Symbols In This Documentation

    CAUTION Failure to observe this information may result in non-seri- ous or minor injury. Units of measurement Note All measurements are given in mm unless stated oth- erwise. | EASYTRON Connect www.stiebel-eltron.com...
  • Page 5: Safety

    Children must never play with the appliance. Cleaning and user maintenance must not be carried out by children without supervision. Test symbols See type plate on the appliance. www.stiebel-eltron.com EASYTRON Connect |...
  • Page 6 ISG web (Internet Service Gateway). are possible: - The system can optimise heat pump heating curves for the EASYTRON Connect underfloor heating controller EHF connected heating circuits. The device controls the underfloor heating system. The device can - The system can open all heating circuits for heat pump be used to control eight channels in each case with up to three defrost.
  • Page 7: Easytron Connect App

    Users have limited access rights to the setting options on the sys- from home via the EASYTRON Connect app. tem. Users can control rooms for which they have authorisation.
  • Page 8: Operating Modes

    OpERATiON EASYTRON Connect app Expert Note Aside from the same rights as Admin, the Expert also has full In STANDBY MODE, DHW heating is not available. access to the setting options in the "Pro" section. The heat pump's frost protection function is activated.
  • Page 9: Dhw Heating

    OpERATiON EASYTRON Connect app Retrofitting wireless components After the extended period away from home, standby mode is switched off again and the heat pump switches to PROGRAMMED MODE (AUTOMATIC MODE). WARNING Electrocution f Devices should be installed by a qualified contrac- Party action tor.
  • Page 10: Operation

    Press and hold the learn button on the device until the dis- play shows an "M". f Keep pressing the "Down" button until the display shows EASYTRON Connect radiator actuator ERS "Pb". f Press the learn button to confirm.
  • Page 11: Troubleshooting

    5.1.4 Anti-lock function Troubleshooting To prevent a radiator valve lock (e.g. due to deposits), the device Status display for EASYTRON Connect base opens and closes the radiator valve automatically. Then the device resumes control according to the settings. station EZE 5.1.5 Activating a lock...
  • Page 12: Status Display For The Easytron Connect Radiator Actuator Ers

    Observe all applicable national and regional regulations and instructions. System description The EASYTRON Connect system is responsible for individual room control in buildings. If a heat pump is connected to the system via ISG web, demand-dependent individual room control is possible.
  • Page 13: Standard Delivery

    - 1 EASYTRON Connect base station EZE To operate the system when away from home, you will need in- - 1 power supply unit for EASYTRON Connect base station EZE ternet access and a mobile device with the EASYTRON Connect - 1 network cable for EASYTRON Connect base station EZE app installed.
  • Page 14: Electrical Connection

    LAN. Note Never exceed a total LAN cable length of 100 m. f Connect the power supply unit to the device. f Plug the power supply unit into a standard socket. | EASYTRON Connect www.stiebel-eltron.com...
  • Page 15 Connection via Enter the address http://10.0.0.1 Note WLAN with in- in the address line of the brows- Changes to the WLAN, e.g. a new router, require you to stallation stick set up the device again. www.stiebel-eltron.com EASYTRON Connect |...
  • Page 16 You can call up the commissioning wizard again later on via the f If a software update is available, install it. device menu. f To operate the system when away from home, activate the connection to EASYTRON Connect. Login Heat pump Note During initial start-up, no pairing is required.
  • Page 17: Connecting Wireless Components

    Observe the chapter "Operation / f Enter the location of the system with postcode and town. Troubleshooting / Status display of EASYTRON Connect base sta- Based on these details, you can view the weather in the app.
  • Page 18: Easytron Connect Underfloor Heating Controller Ehf

    1 Antenna 6 Outputs for actuators f Connect the base station to the available wireless compo- 2 Learn button 7 Actuator nents. Start with the EASYTRON Connect underfloor heating 3 Antenna terminal 8 Power supply controller EHF. 4 ON/OFF indicator...
  • Page 19 Mount the device on the top-hat rail. Ensure that the hooks shows a steady green light. click into place. 13.1.3 EASYTRON Connect base station EZE pairing f Connect the antenna to the antenna terminal on the device. f On the base station, go to the "Wireless components" / "Pair and unpair" / "Pair"...
  • Page 20: Easytron Connect Room Temperature Sensor Ert

    Before the channels can be assigned a room, an EA- SYTRON Connect room temperature sensor ERT must be installed in the relevant room. f Observe the chapter "EASYTRON Connect room tem- perature sensor ERT". 1 Casing top 4 Learn button f Check in the base station "Connection status"...
  • Page 21 Connecting wireless components 13.2.2 EASYTRON Connect base station EZE pairing 13.2.4 Closing the casing f On the base station, go to the “Wireless components” / “Pair f Insert the locking tabs on the casing top into the top of the and unpair” / “Pair”...
  • Page 22: Easytron Connect Radiator Actuator Ers

    Battery symbol flashes Battery charge is low Display flashes Battery charge is critical 13.3.2 EASYTRON Connect base station EZE pairing f On the base station, go to the "Wireless components" / "Pair and unpair" / "Pair" menu. A flashing "M" is displayed.
  • Page 23: Completing The Connection Of Wireless Components

    Remove the USB LAN adaptor from the base station. Danfoss RA Connection via WLAN f Remove the installation stick from the base station. f If required, screw an adaptor to the radiator valve. f Screw the device to the adaptor till it is finger-tight. www.stiebel-eltron.com EASYTRON Connect |...
  • Page 24: Settings

    Switching times can be set for heating rooms. f Check the switching times and adjust them if required. 15. Connection test 15.1 Connection test on the EASYTRON Connect base station EZE f Check in the base station "Connection status" menu that the 1 Learn button wireless components were successfully paired.
  • Page 25 Connection test 15.2.2 EASYTRON Connect room temperature sensor ERT 15.2.3 EASYTRON Connect radiator actuator ERS 1 Learn button f Press the learn button quickly three times. The LED flashes quickly three times to confirm. 1 "Down" button Meaning 2 Learn button LED flashes slowly Performing connection test.
  • Page 26: Failed Connection To The Easytron Connect Base Station Eze

    1 LED f If one or more wireless components are still not connected, 2 Learn button install the repeater (see chapter "EASYTRON Connect repeat- er ERE". 15.4.1 Installation f Plug the device into a 230 V standard socket somewhere between the base station and the unconnected wireless com- ponent.
  • Page 27: Resetting Wireless Components To The Factory Setting

    Press and hold the learn button for seven seconds until the LED flashes. After a successful reset, the LED lights up for two seconds. 15.5.1 EASYTRON Connect radiator actuator ERS The device can be reset to factory settings while installed or un- installed.
  • Page 28: Appliance Shutdown

    On the base station, go to the "Wireless components" / "Pair and unpair" / "Unpair" menu. f Follow the steps for pairing (see chapter "Connecting wire- less components"). 16.2 Dismantling the EASYTRON Connect radiator actuator ERS f Press and hold the learn button for three seconds until "M" is displayed.
  • Page 29: Parameter Overview

    OFF | ON If there is a defrost demand, the heat from the system can be used. Reset OFF | EXE- Reset the heating parameters to the factory CUTE settings. Network and user data are retained. www.stiebel-eltron.com EASYTRON Connect |...
  • Page 30: Room 1 - 24

    Shows the battery charge level. 1...4 Valve 1...4 Shows the current underfloor heating valve position. Demand Shows the set temperature passed on for supplying the heating circuits. ISG HC 1-n Shows the actual temperature of the heating circuit. | EASYTRON Connect www.stiebel-eltron.com...
  • Page 31 The time period is defined by the heat pump (SG Ready). Default name Name of the room. ROOM SET- TiNG Feel-good tem- °C Setback Select the required set room temperature. perature temperature www.stiebel-eltron.com EASYTRON Connect |...
  • Page 32 If the room temperature falls below the set stat pump room temperature by the value set here, the underfloor heating valves close. RESET Reset OFF | EXE- Reset the heating parameters to the factory CUTE settings. Network and user data are retained. | EASYTRON Connect www.stiebel-eltron.com...
  • Page 33: Heat Pump

    Default name Only with heat pump Name of the heat pump. 17.4 Fault messages Menu item / Options Unit Min. Max. Standard System Special fea- Description parameter value tures Reset OFF | RESET Deletes the fault messages. www.stiebel-eltron.com EASYTRON Connect |...
  • Page 34: Configuration

    Valve 1...4 Name of the radiator thermostat or underfloor heating system in the allocated room. HARDWARE: Balancing: RF1-RF24 Temperature calibration of the room temper- ature sensor. Output: Test OFF | Output Test the underfloor heating channels. | EASYTRON Connect www.stiebel-eltron.com...
  • Page 35: Specification

    Specification 18. Specification 18.1.2 EASYTRON Connect underfloor heating controller EHF 18.1 Data table 237736 Application limits 18.1.1 EASYTRON Connect base station EZE Operating temperature range °C -10...+50 Electrical data Power consumption 237737 Max. relay output breaking capacity Application limits...
  • Page 36 Specification 18.1.3 EASYTRON Connect underfloor heating actuator EFS 18.1.4 EASYTRON Connect room temperature sensor ERT 237740 237738 Electrical data Application limits Rated voltage Operating temperature range °C -10...+50 Frequency 50/60 Electrical data Max. starting current 0.55 Power supply Battery 2x 1.5 V AAA...
  • Page 37 Specification 18.1.5 EASYTRON Connect radiator actuator ERS 18.1.6 EASYTRON Connect repeater ERE 237741 237743 Application limits Application limits Operating temperature range °C 0...+40 Operating temperature range °C 0...+40 Max. heating flow temperature °C Electrical data Mechanical load bearing capacity...
  • Page 38 This will not affect warranties issued by any importers. Environment and recycling We would ask you to help protect the environment. After use, dispose of the various materials in accordance with national regulations. | EASYTRON Connect www.stiebel-eltron.com...
  • Page 39 NOTES www.stiebel-eltron.com EASYTRON Connect |...
  • Page 40 Deutschland Verkauf Tel. 05531 702-110 | Fax 05531 702-95108 | info-center@stiebel-eltron.de Kundendienst STIEBEL ELTRON GmbH & Co. KG Tel. 05531 702-111 | Fax 05531 702-95890 | kundendienst@stiebel-eltron.de Dr.-Stiebel-Straße 33 | 37603 Holzminden Ersatzteilverkauf Tel. 05531 702-120 | Fax 05531 702-95335 | ersatzteile@stiebel-eltron.de Tel.

Table of Contents