Calibration Method - DeltaPix H4KAZFSD08DPX User Manual

20x motorized zoom and autofocus digital microscope
Table of Contents

Advertisement

Object Select
Angle
Arbitrary Line
Three-Point method to measure vertical line
Horizontal Line
Rectangle
Three-points Circle
Annulus
Three-points Two Circles
Polygon
Arrow
Make
corresponding relationship between the measurement unit and the sensor pixel size. The monitor's size can be input to achieve
the accurate value of the digital magnification. The
more than 1mm. The detailed
Export
Delete
Setting
Note:1) When the user left-clicks
Toolbar
will be fixed. In this case, the
cursor to the left side of the video window. Only when users left-click the
exit from the measurement mode will they be able to perform other operations in the
Autofocus Control Panel,
2) When a specific measuring object is selected during the measuring process, the
Control Bar
3) To ensure accuracy of the measurement, after the calibration is turned on, the camera will automatically reset,
and then sets the normalization magnification to 20X, and adjusts the focus to the required standard object distance.
If the
"Calibration
Object" on the stage is not clear on the monitor, you need to manually adjust the height of the
bracket to the clearest position, which is the standard object distance. After the
Measurement Toolbar
4) Even if the
Calibration
is at the standard object distance position, it is always better to reset it first, adjust the stand height in the reset state
to see object clear, and ensure that the camera is at the standard object distance position before measurement.

6.3.2 Calibration Method

User needs to prepare a
Move the mouse to the upper side of the video window, the
H4KAZFSD08DPX User Manual
Calibration
to determine the corresponding relation between magnification and resolution, this will establish the
Calibration
the measurement information to CSV file(*.csv)
all the
Measurement Objects
When the measurement ends, left click on a single measuring object and the Object Location & Properties Control
Bar will show up. The icons on the control bar mean
Adjustment, and Delete.
Display/Hide
Camera Control Panel
or the
Synthesis Camera Control
will appear for changing the object location and properties of the selected objects.
to measure the 1mm physical distance on the ruler, which should display 1mm on the monitor.
has been completed, once the user needs to measure, but is not sure whether the camera
Calibration Object
Calibration
needs to be done with the aid of a ruler with an accuracy of
process is described in Sec. 6.3.2
Move
button
on the
will not pop up automatically even if moving the mouse
Toolbar.
such as ruler before Calibration;
Measurement Toolbar
Point
Four-point method to measure the angle
Three-Point method to measure the spacing
Parallel Line
Vertical Line
Center + Radius Circle
Ellipse
Two Circles
Arc
Curve
Scale Bar
Exit from Current Measurement Mode
Left,
Move
Right,
Move
Up,
Measurement
Toolbar, the
button on the
Measurement Toolbar
Camera Control
Object Location & Attributes
Calibration
is completed, use the
will appear. Clicking
Move
Down,
Color
Measurement
to
Panel, the