REQUEST FOR START-UP

2 AMBIENT CONDITIONS

USE
ALTITUDE
AMBIENT TEMPERATURE
MINIMUM LIGHTING LEVEL
REQUIRED
MAX RELATIVE HUMIDITY
INSTALLATION CATEGORY (OR
SURGE CATEGORY or
INSTALLATION CATEGORY)
ELECTRICAL INSULATION CLASS
(ref. IEC 61140)
DEGREE OF POLLUTION
MODEL
HEAT EMISSION INTO THE ROOM -
CYCLE RUNNING
(Assessed considering a cycle containing a
93°C thermal disinfection cycle - not
including the heat emitted by the steam
vent)

3 MACHINE POSITIONING

IMPORTANT
The machine must be positioned with its back against a wall (minimum distance 10 mm) and must be installed by an authorized
SMEG technician. The machine, when suitably prepared, can be placed under a work top
The technician who installs the machine is responsible for the appliance correct operation after it has been installed. The
technician must also provide all the necessary information to the user for correct use.
During installation, it is necessary to remove the scratchproof film on the outer steel surfaces.
The kit of installation accessories (seals and clamps) is located inside the wash chamber.
The machine can be placed up against the sides to the adjacent units, taking care to leave free venting of the steam on the
back: it is therefore advisable that the wall at the back is made of brickwork or some other impermeable material.
Furthermore ensure the heat does not reach any electrical circuits or sockets on the back of the appliance.
The machine is equipped with hoses to supply and drain off the water. These can be positioned towards the right or left,
depending on the installation requirements.
LEVELLING
After positioning the machine, adjust the feet by screwing or unscrewing them in order to adjust the height and level it using
a spirit level so that it is to be horizontal (max angle tolerance allowed: 0.5°).
Correct levelling will ensure that the machine operates in the right way.
CAUTION
Any adjustment, maintenance, etc.. must be performed with the device switched off and disconnected from power sources.
LIFTING AND TRANSPORT
The base of the machine, before leaving the factory, is fixed on a pallet which serves both for lifting and for the transport.
The machine must be handled with a fork-lift truck or transpallet.
Rev. 19 561 0151 08 - EN
AMBIENT CONDITIONS
Indoor
Up to 1000m
From 5°C to 40°C
300 lx
80% for temperatures up to 31°C with linear decrease to 50% at the
temperature of 40°C
II
I
2
GW0160, GW1160, WD1160,
GW2145,
GW4060, WD4060, PW4060,
WD2145
GW3060, GW4090, WD5090
600 W
(2050
BTU/h)
GW4190, WD4190
900 W
( 3070 BTU/hr )
GW6290
1000 W
(3400 BTU/h)
5 - 18