Chengdu Ebyte Electronic Technology Co., Ltd.
(4)Connect to the product with a network debugging tool: here we take the sscom .exe debugging tool as an example.
1 Open a TCPServer service——2 Output the server IP connected to the product: 192.168.4.101 and service port
8886——3 Click Listen (that is, connect to the product, if the word "Listen" cannot be grayed out, please check the above
Parameter setting and hardware connection) - 4 Set data sending rules - 5 Edit product instructions (the picture shows reading the
AI1 channel acquisition value, see "
message received——successful.
(5)See "
4.1 Working Mode

2 Product Introduction

E851-RTU (4440-ETH) is a network IO product that supports 4 digital inputs (default dry contact), 4 differential analog inputs,
and 4 relay outputs. Support Modbus TCP/RTU protocol. The product is highly usable, and users can easily and quickly integrate it
into their own systems to realize Ethernet-based remote control.

2.1 Basic parameters

hardware parameters
Copyright © 2012, Chengdu Ebyte Electronic Technology Co., Ltd.
Chapter 4 Product Functions
" for more connection methods.
project
Product size (H*W*D)
product weight
Operating temperature
storage temperature
Working humidity
storage humidity
Operating Voltage
" for more instructions) - 6 Click "Send" ——7 Return
index
172*107*29mm
457.5± 5g
-20℃~+70℃
-40℃~+85℃
5%~95%
1%~95%
8V~28V
E851-RTU(4440-ETH) User Manual
9