6.3.3.3 Pipe And Hose Connection With Attachment Nipple And Hose Clamp - Ecolab EcoPro-ES-00510X-PFC-00S-1S-S0 Operating Instructions Manual

Dynamic pump
Hide thumbs Also See for EcoPro-ES-00510X-PFC-00S-1S-S0:
Table of Contents

Advertisement

Assembly, installation, modification and upgrades

6.3.3.3 Pipe and hose connection with attachment nipple and hose clamp

Fig. 12: Pipe and hose connection with attachment nipple and hose clamp
A
Detail/Section: Illustration of individual part
1
Hose
2
Union nut
3
Tapered part
4
O-ring
1.
Cut hose (1) straight.
2.
Push the union nut (2) and clamp it over the hose (1).
3.
Push the hose clamp (6) over the hose (1).
4.
Push the hose (1) onto tapered part (3) up to the stop collar (detail A1).
5.
Place the O-ring (4) in the groove of the suction or pressure valve (5).
6.
Tighten the union nut (2) (detail B1).
7.
Push the hose clamp (6) downward and tighten (detail B1).
417102264 Rev. 5-01.2019
5
Suction valve, pressure valve
6
Hose clamp
A1 Pipe or hose attached
B1 Valve connection: Target state after assembly