2
1. Negative Terminal
2. Positive Terminal
3. Battery
4. Hold Down Bracket
Figure 24
1. Remove battery from unit.
2. Clean terminals and battery cable ends
with wire brush.
3. Coat terminals with dielectric grease or
petroleum jelly.
4. Replace battery.
Charging the Battery
IMPORTANT: DO NOT fast charge. Charging
at a higher rate will damage or destroy
battery. ONLY use an automatic charger
designed for use with your battery.
ALWAYS follow information provided on
battery by battery manufacturer. Contact
battery manufacturer for extensive
instructions to charge battery.
1. Remove battery from unit. See Remove
Battery on page 32.
2. Place battery on bench or other well-
ventilated place.
3. Connect positive (+) lead of charger to
positive (+) terminal, and negative (–)
lead to negative (–) terminal.
4. Charge battery according to charger and
battery manufacturers' instructions.
5. Replace battery. See Replace Battery on
page 32.
Jump-Starting
Gravely does not recommend jump-starting
your unit. Jump-starting can damage engine
and electrical system components. See your
engine manual for more detailed information.
1
4
3

ELECTRICAL SERVICE

(Figure 25)
Replacing Fuses
IMPORTANT: AVOID DAMAGE! When
replacing fuses use only replacements with
the same amperage rating or you may
damage the circuit.
The unit is equipped with fuses to protect the
multiple circuits. The fuses are located in the
fuse box on the right side of the seat.
1. Remove defective fuse from socket.
2. Check metal clip in fuse window and
discard fuse if clip is broken.
3. Install new fuse of equal amperage rating
into socket.
Replacing Relays
NOTICE: (Relays are interchangeable. Use
only quality replacement relays (see Service
Parts on page 45).
The unit is equipped with relays located in the
fuse box on the right side of the seat.
1. Remove defective relay from socket.
2. Install new relay into socket.
4
2
3
1. Fuse Box
2. Start Relay
3. Starter Solenoid Relay
4. PTO Relay
5. 10-Amp Fuse (Run Circuit)
6. 10-Amp Fuse (Power Seat Circuit)
7. 20-Amp Fuse (Charging Circuit)
8. 10-Amp Fuse (PTO Circuit)
9. 15-Amp Fuse (Auxiliary Circuit)
EN - 33
5
7
8
Figure 25
1
6
9