Error
Messa
Possible Cause & Solution
ges
Power
Electric dryer power cord is not
Supply
connected correctly, or house power
/ High
supply is incorrect.
Voltage
• Reset circuit breaker or replace
/ Low
fuse. Do not increase the fuse
Voltage
capacity.
House fuse is blown, circuit breaker
has tripped, or power outage has
occurred.
• If the problem is a circuit overload,
have it corrected by a qualified
electrician.
Gas
Gas supply or service turned off. (Gas
Supply
Model only.)
• Confirm that house gas shutoff and
the dryer gas shutoff are both fully
open.
Duct
Exhaust system is too long or has too
Blocka
many turns/restrictions.
ge
• Do not use the appliance until the
(80%) /
exhaust system has been cleaned
Duct
and/or repaired. Using the
Blocka
appliance with severely restricted
ge
exhaust is dangerous and could
(90%) /
result in a fire or other property
Duct
damage.
Blocka
ge
• Check the outside dryer vent while
(95%)
the appliance is operating to make
sure there is strong airflow. If the
exhaust system is extremely long,
have it repaired or rerouted.
Door
Door open error.
Open
• Do not open the door when doing
installation mode. Restart
Installation mode.
Restricted or Blocked Airflow
Avoid long runs or runs with multiple elbows or
bends.
Excess or crushed transition duct
Too many elbows or exhaust too long
Check for blockages and lint buildup.