PERIODIC CHECKS

Perform annual Periodic Checks at the beginning of the season according to the following
instructions (refer also to safety instructions in chapter 2):
1. Check the condition of the body seal. If necessary, replace the body seal.
2. Verify that all the brush units are in contact with the filtration screen. If necessary,
adjust the position of the brush units or replace them according to "Brushes shaft and
Brush units Removal & Installation."
3. Check the condition of the filtration screen assembly. If defective, replace according to
"Filtration Screen Assembly Removal & Installation."
4. Check the filtration screen seals condition. Lubricate with silicon grease.
5. Check the condition of the bearings, replace if damaged or deformed.
6. Check existence of grease on the motor axis.
7. Check the filter housing for paint damage and corrosion. If required, clean area with
sandpaper and apply a thin layer of basic + epoxy paint.
8. Check for leaks.