INSTALLATION INSTRUCTIONS
Ergonomic Bidet Seat
Side Entry: 30502
Bottom Entry: 30504
Please read all instructions before installation and leave this document
with the end user for future reference as it contains important warranty information
AKW BIDET
Consilio Bidet Seat
Side Entry: 30501
Bottom Entry: 30503

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 30501 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Akw 30501

  • Page 1 INSTALLATION INSTRUCTIONS Ergonomic Bidet Seat Consilio Bidet Seat Side Entry: 30502 Side Entry: 30501 Bottom Entry: 30504 Bottom Entry: 30503 Please read all instructions before installation and leave this document with the end user for future reference as it contains important warranty information...
  • Page 2: Table Of Contents

    Contents ..........................5 Important Safety Information ............................6 Important Information ............................7 Technical Specification .............................8 Technical Dimensions ............................9-10 Side Entry Installation ..........................11-12 Bottom Entry Installation ........................... 13-14 Remote Control Installation ................................ 15 Maintenance ................................16 Contact Us General: 01905 823 298 www.akw-ltd.co.uk...
  • Page 3: Overview

    Seated detector Air dry Female wash Rear wash Program upgrade Power light/ Night detector LED Fault Indication Air dry Rear wash Unlatch Button/ Night light Thermostat reset Button Female wash Order: 01905 823 299 orders.akw-ltd.co.uk Technical Support: 01905 560 219...
  • Page 4: Contents

    Flexible Water Pipe Plates & Seat Hinge Covers Valve Remote Control Remote Control Holder Remote Holder Fixings, (Batteries not supplied) & Cord Cover & Double Sided Tape Bottom Entry Only - 3 Pin Waterproof Cable Connector General: 01905 823 298 www.akw-ltd.co.uk...
  • Page 5: Important Safety Information

    • Children must not play with the appliance. Cleaning and user maintenance must not be undertaken by children. Order: 01905 823 299 orders.akw-ltd.co.uk Technical Support: 01905 560 219...
  • Page 6: Important Information

    These instructions are provided to advise the minimum standards of installation and recommends what the best practice for the installation is. Due to the very wide variability of possible installation conditions, AKW cannot provide all circumstances for the installation. AKW cannot accept any liability in connection with this information or its use.
  • Page 7: Technical Specification

    Temperature 40~52°C Device Dry Cycle Time 3 minutes Safety Device Thermal fuse/Thermostat frequency ~2460MHz Remote Maximum Rf output power 0dBm Control Type of Batteries 2x 1.5v lR03 aaa (not included) Order: 01905 823 299 orders.akw-ltd.co.uk Technical Support: 01905 560 219...
  • Page 8: Technical Dimensions

    Technical Dimensions Ergonomic Bidet Seat Consilio Bidet Seat Side Entry: 30501 Side Entry: 30502 Bottom Entry: 30503 Bottom Entry: 30504 160 (+/- 20mm) 160 (+/- 20mm) General: 01905 823 298 www.akw-ltd.co.uk...
  • Page 9: Side Entry Installation

    Side Entry Installation Caution: Ensure that the power supply is turned off at the mains supply and the water is turned off at the isolation valve. Order: 01905 823 299 orders.akw-ltd.co.uk Technical Support: 01905 560 219...
  • Page 10 Side Entry Installation 1/2” Isolating valve & Tee Junction 1/2” x 1/2” 1/2” x 1/2” flexible Cistern pipe (not supplied) water pipe Refer to the user instructions for aKw Bidet functions and operations. General: 01905 823 298 www.akw-ltd.co.uk...
  • Page 11: Bottom Entry Installation

    Bottom Entry Installation Refer to the toilet cistern installation instructions for completing the electrical and plumbing installation, and then the pan instructions before attaching the aKw Bidet. Order: 01905 823 299 orders.akw-ltd.co.uk Technical Support: 01905 560 219...
  • Page 12 Bottom Entry Installation 3/8” x 1/2” flexible pipe Connector 1/2” x 1/2” 3 pin waterproof Isolating valve Cable Connector Refer to the user instructions for Bidet functions and operations. General: 01905 823 298 www.akw-ltd.co.uk...
  • Page 13: Remote Control Installation

    Remote Control Installation Using wall fixings Recommended Installation area for the remote control holder. 200 mm 200 mm 200 mm 200 mm Order: 01905 823 299 orders.akw-ltd.co.uk Technical Support: 01905 560 219...
  • Page 14 Remote Control Installation Using double-sided tape Recommended Installation area for the remote control holder. 200 mm 200 mm 200 mm 200 mm General: 01905 823 298 www.akw-ltd.co.uk...
  • Page 15: Maintenance

    Do not tilt or rotate the bidet until the water has finished draining from the tank. Do not turn the appliance over to drain the tank. Only drain from underneath and catch the water. Turn and pull out to open. Order: 01905 823 299 orders.akw-ltd.co.uk Technical Support: 01905 560 219 Insert and turn to close...
  • Page 16: Contact Us

    If the issue is still unresolved, contact AKW Technical Enquiries who will provide further advice and arrange for a maintenance engineer to visit if necessary. None of the foregoing affects your statutory rights.