STANDER C A T I N V E N T O ™ USER MANUAL...
Page 2
Akces-Med employee or at specialized medical store! AKCES-MED. Ltd. reserve the right to introduce technical and trading changes in the content of the instruction without warning. Product marked with the CE sign is Class I medical device, of...
8. The use of Stander ....................18 8.1 Preparation of the patient................18 8.2 Preparation of device before each use............19 8.3 Upright position ....................21 9. Safety rules .......................24 10. Terms of warranty....................26 10. Maintenance and cleaning ...................27 11. Labelling........................31 www.akces-med.com +48 17 864 04 77 export@akces-med.com...
Page 4
It enables independent (with supervision), safe standing, play and education. Thanks to its simplicity CAT II INVENTO™ is a valuable device rehabilitation of handicap children at home, hospitals, rehabilitation centers. Used properly may significantly improve the quality of life of children.
User manual should be kept in easily accessible place. It is designed for people who look after the disabled , and for both doctors as well as physiotherapists who operate the device. Before using the CAT II INVENTO™ standing frame, user is obliged to familiarize himself/herself with user manual.
Page 6
200/110 mmHg, pulmonary hypertension, cardiac arrythmias, moderate heart valve disease); respiratory system (unstable asthma) and unstable metabolic disorders, it is necessary to monitor the user while standing in order to prevent serious complications. www.akces-med.com +48 17 864 04 77 export@akces-med.com...
1. Foot rest with street castors with gas spring 2. Foot stabilization 3. Knee stabilization 4. Pelvis supports 5. Chest supports 6. Pelvis stabilizing belt 7. Chest stabilizing belt 8. Head rest (used during supine standing) 9. Tray www.akces-med.com +48 17 864 04 77 export@akces-med.com...
0-90 [kg] Maximum user weight Unit Weight and dimensions of the device [cm] Product width [cm] Product length [cm] Product height [kg] Product weight Note: Dimensional tolerance in the table is +1/-1 cm. www.akces-med.com +48 17 864 04 77 export@akces-med.com...
5mm key (point 11 page 6) included with the device (picture 5.1) place the foot rest in the required position (picture 5.2) insert the screw into the whole and tighten it with the key (picture 5.2) picture 5.2 picture 5.1 www.akces-med.com +48 17 864 04 77 export@akces-med.com...
(pict. 5.8) to prepare the device to the supine position additionally the knee supports must be adjusted (pict. 5.9) picture 5.7 picture 5.6 picture 5.9 picture 5.8 www.akces-med.com +48 17 864 04 77 export@akces-med.com...
In order to properly adjust the heel stabilization it is necessary to: adjust the location and the distance between the heel stabilizations ź (pict. 5.12) adjust the width of heel stabilization to fit the shoes of the patient ź (pict. 5.13) www.akces-med.com +48 17 864 04 77 export@akces-med.com...
Page 14
3D adjustment (optional equipment) If the device is equipped with 3D footers you have to adjust: location and distance between the footers (pict. 5.14) lateral inclination of the footers (pict. 5.15) picture 5.14 picture 5.15 www.akces-med.com +48 17 864 04 77 export@akces-med.com...
CAUTION! The adjustment of the tray in the supine position must be done after the patient is placed in the device. In case of prone position the tray is adjusted before the patient is placed in the device! www.akces-med.com +48 17 864 04 77 export@akces-med.com...
Page 16
Please follow these steps so as to mount soft cover for tray: picture 6.22 Adhere 5 adhesive Velcro tapes; ź Put soft cover in a way that its edges cover ź tray edges. picture 6.23 picture 6.24 www.akces-med.com +48 17 864 04 77 export@akces-med.com...
1- assemble the head rest 2- change position of the tray support 3- assemble knee supports on the other side of the knee stabilization 4- change position of the heel stabilization in the footers www.akces-med.com +48 17 864 04 77 export@akces-med.com...
THE USE OF STANDER CAUTION! Stander has to be used CAT II INVENTO™ with compliance to guidelines included in this user manual. Remember to use the product only with someone who is trained and knowledgeable. 8.1. Preparation of the patient Before using the product, it is essential to make sure that: ·...
ź stabilizing belts (if the device is equipped) open the knee stabilization, releasing the catch hold and turning it by ź 90°(pict. 8.2) www.akces-med.com +48 17 864 04 77 export@akces-med.com...
Page 20
CAUTION! Remember to make sure that all belts and locking are correctly adjusted and fastened. Check also if fastenings from adjustable elements are firmly tightened. www.akces-med.com +48 17 864 04 77 export@akces-med.com...
Make changes if necessary klik 5. Fasten the patient with the aid of all belts and close knee support. Make sure that all castors are situated in correct places (fig. 8.3) klik picture 8.3 www.akces-med.com +48 17 864 04 77 export@akces-med.com...
Page 22
If these undesirable side-effects still occur it is necessary to contact doctor. If these side effects disappeared, remember to inform doctor so as to make decision concerning further upright position process. www.akces-med.com +48 17 864 04 77 export@akces-med.com...
Page 23
5. Unfasten belts which stabilize foot, hips and chest. 6. Make sure that all belts and precautions do not block the patient. 7. Move the patient and place him on a prepared device. www.akces-med.com +48 17 864 04 77 export@akces-med.com...
It is highly important to consult either doctor or physiotherapist in order to make right decision concerning the choice of CAT II INVENTO™ and its size. It is also essential to familiarize with the guidelines described in user manual before using the device.
Page 25
Do not use a product that has any signs of damage, tearing or wear. Only anundamaged product and proper use guarantee its right and safe working. If the product is damaged, discontinue use and contact the manufacturer. www.akces-med.com +48 17 864 04 77 export@akces-med.com...
Next, manufacturer determines again how long the product can be used and, moreover, the date of the next service will be determined. 5) If product is damaged, please contact our dealer or Akces-MED Sp. z. o. o customer service (ph. 17/864 04 77) www.akces-med.com +48 17 864 04 77 export@akces-med.com...
After disinfection, wait until the element is completely dry, especially in the case of upholstery. Before using the disinfectant, first check in an invisible place whether the product will not discolor or damage the disinfected surface. www.akces-med.com +48 17 864 04 70 produkcja@akces-med.com...
Page 28
Remember that upholstery has to be always dry before using! The manufacturer of the standing frame, Akces-MED Sp. z o. o., is not responsible for any damages caused by using unsuitable cleaners. Before using it is necessary to: clean wheels;...
Page 29
Before using the Remove dirt (e.g. hair, food remains, etc.) product, check if the upholstery is dry. from the moving parts of the product. www.akces-med.com +48 17 864 04 70 produkcja@akces-med.com...
Page 30
After that, the manufacturer will re-define the life time of the product and the date of the next check. The list of all spare parts is available for download after selecting a product on www.akces-med.com. www.akces-med.com +48 17 864 04 77 export@akces-med.com...