Water Specialist CD/CZ
Control Valve
Programming Manual

Advertisement

Table of Contents
loading

Summary of Contents for Charger Water Specialist CD

  • Page 1 Water Specialist CD/CZ Control Valve Programming Manual...
  • Page 2 Page 2 CD Manual...
  • Page 3: Table Of Contents

    CD Manual Page 3 Table of Contents Front Cover and Drive Assembly ......................4 OEM General Programming Instructions ....................5 OEM Configuration Setup ........................7 OEM Softener System Setup ........................13 Setting Options Table ...........................17 OEM Filter System Setup ........................18 Installer Display Settings ........................20 User Display Settings ..........................21 Diagnostics ............................24 Valve History ............................26...
  • Page 4: Front Cover And Drive Assembly

    Page 4 CD Manual Front Cover and Drive Assembly Drawing No. Order No. Description Quantity V3984-01 WS1CD FRONT COVER ASSEMBLY V3107-01 WS1 MOTOR ASY V3002-A WS1 DRIVE BRACKET ASY V3985CD-04BOARD WS1 THRU 2 CD4 PCB REPL V3985CZ-04BOARD WS1THRU2 CZ4 WIFI PCB REPLACE V3110 WS1 DRIVE REDUCING GEAR 12X36 V3109...
  • Page 5: Oem General Programming Instructions

    CD Manual Page 5 OEM General Programming Instructions The control valve offers multiple procedures that allow the valve to be modified to suit the needs of the installation. These procedures are: • OEM Configuration Setup • User Display Settings • OEM Softener System Setup •...
  • Page 6 Page 6 CD Manual Once the OEM Cycle Sequence has been set, the other procedures can be accessed in any order. Details on each of the procedures are provided on the following pages. To “lock out” access to diagnostic and valve history displays and modifications to settings except hardness, day override, time of regeneration and time of day by anyone but the manufacturer, press ▼, NEXT, ▲, and CLOCK in sequence after settings are made.
  • Page 7: Oem Configuration Setup

    CD Manual Page 7 OEM Configuration Setup Step 1CS – Press NEXT and ▼ simultaneously for 3 seconds and release. Then press NEXT and ▼ STEP 1CS simultaneously for 3 seconds and release. If screen in Step 2CS does not appear in 5 seconds the lock on the valve is activated.
  • Page 8 Page 8 CD Manual Step 4CS – Allows selection of one of the following using ▲ or ▼: STEP 4CS • the Control Valve to act as an alternator; or • the Control Valve to have a no hard water bypass: or •...
  • Page 9 CD Manual Page 9 Retracted Extended Valve B in Service Position = Valve A in Service Position = MAV piston rod Extended MAV piston rod Retracted Note: Clack Twin Alternator Operations • Twin alternating systems can be programmed with a day override setting combined with the normal volume-based regeneration programming.
  • Page 10 Page 10 CD Manual Configuring the Control Valve for No Hard Water Bypass Operation: Select NO HARD BYPASS for control operation. For no hard water bypass operation the three wire connector is not used. Selection requires that a connection to MAV or a Clack No Hard Water Bypass Valve is made to the two pin connector labeled MAV located on the printed circuit board.
  • Page 11 CD Manual Page 11 Step 6CS – This allows the use of an outside signal to control the initiation of a regeneration. STEP 6CS Selection only matters if a connection is made to the two pin connector labeled DP SWITCH located on the printed circuit board.
  • Page 12 Page 12 CD Manual Step 8CS – Press ▼ or ▲ until BACKWASH appears. Press NEXT to go to Step 9CS. Press STEP 8CS REGEN to return to previous step. Step 9CS - Press ▼ or ▲ until Regenerant Draw DN appears. Press NEXT to go to Step 10CS. STEP 9CS Press REGEN to return to previous step.
  • Page 13: Oem Softener System Setup

    CD Manual Page 13 OEM Softener System Setup Step 1S – Press NEXT and ▼ simultaneously for 3 seconds and release. If screen in Step 2S does not STEP 1S appear in 5 seconds the lock on the valve is activated. To unlock press ▼, NEXT, ▲, and CLOCK in sequence, then press NEXT and ▼...
  • Page 14 Page 14 CD Manual Step 9S – Set Volume Capacity using ▲ or ▼. If value is set to: STEP 9S • AUTO capacity will be automatically calculated and reserve capacity will be automatically estimated; • OFF regeneration will be based solely on the day override set (see Installer Display Settings Step 4I); or •...
  • Page 15 CD Manual Page 15 Step 13S: Set Relay DURATION TIME using ▲ or ▼. STEP 13S • If REGEN TIME is selected in Step 11S, the relay will deactivate after the time set has expired. Ranges from 0:01 to 500:00 minutes. •...
  • Page 16 Page 16 CD Manual Step 21S: Status display only, if Step 18S is set to TIME or BOTH. Shows time remaining to Service Alarm. Can STEP 21S be reset to the initial value by pressing ▲ and ▼ for approximately 3 seconds. Press NEXT to exit OEM Softener System Setup or to go to Step 22S.
  • Page 17: Setting Options Table

    CD Manual Page 17 Setting Options Table Regeneration Regeneration System Type Day Override Option Type Regeneration occurs at the next regeneration time when Softening Auto Normal 1-28 days volume capacity falls below the reserve capacity, or the specified number of days is reached, whichever comes first. Regeneration occurs at the next regeneration time when Softening Auto...
  • Page 18: Oem Filter System Setup

    Page 18 CD Manual OEM Filter System Setup Step 1F – Press NEXT and ▼ simultaneously for 3 seconds and release. If screen in Step 2F does not STEP 1F appear in 5 seconds the lock on the valve is activated. To unlock press ▼, NEXT, ▲, and CLOCK in sequence, then press NEXT and ▼...
  • Page 19 CD Manual Page 19 Step 8F – Set Volume Capacity using . If value is set to: ▲ or ▼ STEP 8F • “OFF” regeneration will be based solely on the day override set (see Installer Display/Settings Step 4I); or •...
  • Page 20: Installer Display Settings

    Page 20 CD Manual Installer Display Settings STEP 1I - Press NEXT and ▲ simultaneously for 3 seconds. STEP 1I STEP 2I – Display Language: Choose between English and Spanish. Press NEXT to go to Step 3I. STEP 2I Press REGEN to exit Installer Display Settings. STEP 3I –...
  • Page 21: User Display Settings

    CD Manual Page 21 User Display Settings General Operation When the system is operating, one of several displays may be shown. The displays normally rotate, however pressing NEXT will pause on the selected display for 5 minutes. Pressing NEXT will alternate between the displays.
  • Page 22 Page 22 CD Manual Regeneration Mode Typically a system is set to regenerate at a time of low water usage. An example of a time with low water usage is when a household is asleep. If there is a demand for water when the system is regenerating, untreated water will be used.
  • Page 23 CD Manual Page 23 Power Loss If the power goes out the system will keep time until the battery is depleted. If an extended power outage occurs, the time of day will flash on and off which indicates the time of day should be reset and the non-rechargeable battery replaced. The system will remember the rest.
  • Page 24: Diagnostics

    Page 24 CD Manual Diagnostics STEP 1D – Press ▲ and ▼ simultaneously for three seconds. If screen in step 2D does not appear STEP 1D in 5 seconds the lock on the valve is activated. To unlock press ▼, NEXT, ▲, and CLOCK in sequence, then press ▲...
  • Page 25 CD Manual Page 25 STEP 7D – Flow rate, maximum last seven days: Use ▲ or ▼ to display the maximum flow rate STEP 7D in gallons per minute that occurred in each of the last seven days. This display will equal zero if a water meter is not installed.
  • Page 26: Valve History

    Page 26 CD Manual Valve History STEP 1VH – Press ▲ and ▼ simultaneously for three seconds and release. Then press ▲ and ▼ STEP 1VH simultaneously and release. If screen in step 2VH does not appear in 5 seconds the lock on the valve is activated.
  • Page 27 CD Manual Page 27 Revision History: 8/24/2022 COVER: CD/CZ PAGE 4: V3985CD-04BOARD WS1 THRU 2 CD4 PCB REPL V3985CZ-04BOARD WS1THRU2 CZ4 WIFI PCB REPLACE V4228-01BOARD WS1THRU2 WIFI REV2 PCB REPLACE Add Wi-Fi board drawing PAGE 6: Add text: If using a Wi-Fi enabled valve, another display showing connection information will also be available. Add text: If using a Wi-Fi enabled valve, pressing CLOCK and ▼...
  • Page 28 Under Salt Alarm: “If the Salt Level Alarm was set in Step 23S ” PAGE 26: Step 2VH - updated display to current version Values in steps 3VH through 6VH cannot be reset. Charger Water Treatment Products 8150 N. Lehigh Ave, Morton Grove, IL 60053 www.chargerwater.com/FAQ Form No. V3435CD • 12/8/2022...