Surface Mounting Installation (Solid Wood) - BQT Solutions YD30D Installation And Operating Instructions Manual

Cobalt double sideload lock
Table of Contents

Advertisement

6.3

Surface Mounting Installation (Solid Wood)

1. Preparing the mounting surface
Install two 10Gx1" self-tapping screws (included with housing) in
the mounting surface, as per the product dimension drawings they
should be 220mm apart, 20mm from the surface edge.
2. Preparing the housing
An 8mm hole should be drilled through the housing wall at the
position chosen by the installer for the wiring to enter. The wiring
can be guided to the housing through surface mount conduit, or
through a hole in the mounting surface material. Push a rubber
grommet (included with housing) over the drilled hole to protect the
wires from any sharp edges.
3. Fitting the housing
Position the keyhole cutouts of the housing over the screw heads
and slide into position flush with the surface edge, and then tighten
screws in place to secure the housing.
4. Wiring the lock
Feed the wires through the 8mm hole in the housing and a
connection can be made to the supplied wire loom which in turn
plugs into the lock.
Refer to the Wiring section of this document for detailed
instructions on wiring.
5. Setting the operating mode
Ensure the operating mode switch is positioned to the
required state, Fail Safe or Fail Secure.
Refer to the Operating Mode section of this document for
detailed instructions on wiring.
6. Fitting the lock and strike plate
The lock can be placed into the housing, ensuring that the
wiring integrity is maintained, and then secured in place with
M5 machine screws (included with housing). Please ensure
the lock is the correct orientation as to pull the door into the
door jamb.