Thermostatic remote control

Advertisement

OPERATING
DTIR1 remote controller has an LCD
display and 3
keys for operation and configuration
(MODE, +, -).
pic. 3
BASIC FUNCTION
ATTENTION: A default configuration
displays ambient temperature. To change it
see paragraph ADVANCED FEATURES
MANUAL MODE
This mode is for the manual setting of the temperature.
You can define two temperature levels and record them
in the controller's memory as COMFORT and ECO
settings. To set COMFORT: press MODE and choose
Then set exact temperature pressing + and -. To set
ECONOMY (ECO) temperature — press MODE and
choose
icon. Then set exact temperature pressing +
and -. A thermostat controls the output of the heating
element to achieve and sustain a set temperature. To
change temperature press + or -.
All changes made in COMFORT and ECO settings will
be recorded in controller's memory and later will be
used in AUTOMATIC MODE.
DRYING MODE
Choose
symbol by pressing MODE key (other icons
off). The time remaining to finish the DRYING mode
is displayed on LCD. By pressing + and – set the time
from 15 min. to 4 h. After having finished drying time
the controller switches to automatic mode.
The user can define 2 levels of ambient temperature
identified by easily remembered symbols:
COMFORT (Higher temperatures)
ECONOMY (Lower temperatures)
Each of these levels can be set with accuracy of up to
0.5°C. Both levels can be set according to your own
needs and used during the day and night. They can also
be changed at any time.
AVAILABLE WORKING MODES:
Manual mode: user changes manually settings of the
controller.
Automatic mode (24 hr Timer)
between pre set program, changing between the
settings
or
or :
Drying mode
: heater is switched on with full power
for the time set by user.
ANTIFREEZE
: prevents heating agent (in radiator) from
freezing when temperature falls below set point.
AUTOMATIC MODE (24 h TIMER)
Enables the heating element to switch on and off
using the 24 hr timer and your preset COMFORT and
ECO settings according to your programmed sched-
ule. Automatic mode has 96 cells of memory, every
single one covers time period of 15 minutes. For every
15 min you can set one of three
settings
or
or
temperatures have to be set in Manual Mode before
the AUTO Mode starts. Any manual change during
AUTO mode (buttons +/-) lasts for 2 hours and then
controller returns to its previous AUTO mode settings.
Default settings of AUTO mode shows picture 1.
TO MODIFY AUTO MODE PERMANENTLY:
1 PRESS THE KEYS MODE AND + TOGETHER FOR
5 SEC —
SYMBOL WILL START BLINKING AND
00:00 WILL APPEAR ON THE SCREEN.
2 WITH + AND — KEYS SELECT THE TIME (FOR-
WARD AND BACK).
3 BY PRESSING MODE BUTTON CHANGE SET-
TINGS FOR THE TIME SHOWN ON LCD (CHOOSE
BETWEEN:
OR
4 PROGRAMMING ALWAYS STARTS AT 0.00 AND
ENDS AT 24.00 (24HR CLOCK), AFTER A PAUSE
OF 15 SEC THE CONTROLLER AUTOMATICALLY
REMEMBERS YOUR CHANGES.
: automatically switches
. The COMFORT and ECO
OR
).
2

Advertisement

loading