Please visit www.parametric.ch for the latest documentation. Preparing the device 1 Opening the Enclosure Remove the four screws from the casing to gain access to the device. 2 Connecting the Programming Cable Connect the sensor to your Computer using a USB Cable.
Page 4
3 Install PCR Setup Tool Download the free PCR Setup Tool by opening the following URL: https://www.parametric.ch/downloads/ Download PCRSetupTool_Setup.exe and follow the instructions of the installer. Ignore all security warnings. 4 Set LoRaWAN Keys Start the PCR Configurator tool. After some seconds you will see the device information (1).
Page 5
5 Set TX Interval 6 Overview of Application Settings 7 Overview of LoRaWAN Settings www.parametric.ch/product/pcr2-od...
Connect the mains (AC) supply in compliance with national regulations (VDE0100 and EN50178) Before closing the casing, make sure that the two components are aligned as depicted. The cable gland and the antenna are pointing downwards. Ensure that the cable gland is fully tightened. www.parametric.ch/product/pcr2-od...
Page 7
Installation height: 0.5…4m above peoples heads Installation direction: Heading down, LEDs in line with direction of movement Separation angle: 40° (Distance between persons) Avoid: Side-by-side walking Groups Too close to each other Too wide entries (detection angle is 34°) www.parametric.ch/product/pcr2-od...
Page 9
In the interest of continuous further development of our equipment, we have to make changes to the scope of delivery in form, technology and equipment reserved. We also ask for your understanding that no claim can be derived from data and illustrations of this manual. Contact Address Parametric GmbH Waldeggstrasse 82 3800 Interlaken Switzerland www.parametric.ch...