Electrical Installation - HAMOKI B10 Instruction Manual

Planetary mixer
Table of Contents

Advertisement

Electrical Installation

ELECTRICAL INSTALLATION:
The electrical installation of the mixer must conform to the local or national electricity board
regulations.
A competent person must carry out the electrical installation. Ensure that the electrical supply
agrees with the machine specification, prior to connection.
The mixer is 'class l' appliances where the protection against electric shock does not rely solely
on basic insulation. An external electrical isolator and MCB/fuses (both items supplied by
others) must be fitted to the incoming electrical supply to the mixer. In addition a 35mA
residual current device is strongly recommended to provide extra protection
This appliance should be connected to the point of the supply with the impedance value
Zsys less than (0.05+j0.03)Ω.
If the supply cord is damaged, it must be replaced by a special cord or assembly available
from the manufacturer or retailer.
B10, B20
11

Advertisement

Table of Contents
loading

This manual is also suitable for:

B20B30B40B60

Table of Contents