Adicos GSME-X20 Supplementary Instructions Manual

Fire gas detector
Hide thumbs Also See for GSME-X20:

Advertisement

GSME-X20
DO NOT OPEN IN GAS
LOADED ATMOSPHERE
EN
IP64
Supplementary Instruction Manual for GSME-X20
Fire Gas Detector
GTE Industrieelektronik GmbH | Helmholtzstr. 21, 38 – 40 41747 Viersen | Germany | +49 2162 3703-0 | info@gte.de

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GSME-X20 and is the answer not in the manual?

Questions and answers

Summary of Contents for Adicos GSME-X20

  • Page 1 GSME-X20 DO NOT OPEN IN GAS LOADED ATMOSPHERE IP64 Supplementary Instruction Manual for GSME-X20 Fire Gas Detector GTE Industrieelektronik GmbH | Helmholtzstr. 21, 38 – 40 41747 Viersen | Germany | +49 2162 3703-0 | info@gte.de...
  • Page 2 Supplementary Instructions for GSME-X20 Article number: 408-2410-004 Index: EN22 Release date: 11.01.2023 – Translation – Manufacturer GTE Industrieelektronik GmbH Helmholtzstr. 21, 38-40 41747 Viersen GERMANY Support hotline: +49 2162 3703-0 E-Mail: support.adicos@gte.de © 2023 GTE Industrieelektronik GmbH – This document and all figures contained may not be...
  • Page 3 COS system ensures reliable early detection of embers and smoldering fires even in adverse environments. ADICOS GSME fire gas detectors detect at an early stage gases that are characteristic for developing fires. They detect both open and concealed smoldering fires. Highly sensitive and at the same time robust, they are ideal for fire gas detection in industrial environments –...
  • Page 4: Table Of Contents

    ADICOS Mounting Plate ........
  • Page 5: About This Manual

    Objective This manual describes the special requirements on installation, wiring, commissioning, and operation of ADICOS detectors for explosive atmospheres up to ATEX zone 20. They are exclusively addressed to knowledgeable specialist personnel (–› Chap. 2, Safety instructions). Explanation of Symbols This manual features a continuous structure for best possible comprehension.
  • Page 6: Safety Instructions

    ATEX operating directive. Intended Use ADICOS GSME-X20 are designated for the detection of fire scenarios in explosive atmospheres of ATEX zone 20, 21 and 22. In this context, the operating parameters described in Chap. 9, »Technical Data« must be met. Any deviating use requires prior consultation with the manufacturer.
  • Page 7: Personnel Qualification

    Personnel Qualification Any work on ADICOS systems may only be performed by qualified personnel. Per- sons, who can perform work on electrical systems and recognize possible dan- gers based on their professional education, knowledge, and experience as well as knowledge of the applicable provisions, are considered qualified personnel.
  • Page 8: Structure

    Alarm NO white Relay output X6 a Alarm NO black Relay output X7 a Fault NC white Relay output X7 e Fault NC black M-bus max. 40 V non-polarized white with series resistor, standard 680 Ω 408-2410-004 EN22 ADICOS GSME-X20...
  • Page 9: Display Elements

    The signal dome is a translucent element. It includes the status LED to indicate the operating condition of the X20 detectors. The light signals of the ADICOS X20-Detectors are identical to the signals of the ADICOS detectors without explosion protection prop- erties.
  • Page 10: Installation

    DANGER! Risk of explosion due to electrical voltage in hazardous areas. The electronics of ADICOS GSME-X20 works with an electrical voltage that can trigger an explosion in potentially explosive atmospheres. • Do not open enclosure! Mount the device with closed housing! •...
  • Page 11: Wiring

    DANGER! Risk of explosion due to electrical voltage in hazardous areas. The electronics of ADICOS GSME-X20 works with an electrical voltage that can trigger an explosion in potentially explosive atmospheres. • Do not open enclosure! Mount the device with closed enclosure.
  • Page 12: Maintenance

    Detector Replacement DANGER! Risk of explosion due to electrical voltage in hazardous areas. The electronics of ADICOS GSME-X20 works with an electrical voltage that can trigger an explosion in potentially explosive atmospheres. • Do not open enclosure! • De-energize the entire detector system and secure against unintentionally reactivation for all wiring work! •...
  • Page 13: Technical Data

    Explosion protection class: Ex ta IIIC 105°C Da Certified according to ATEX and IECEx Max. surface temperature: °C < 105 Device group: II, category 1D Type approval: Certificate according to 2014/34/EU Other Bending radius > 91,5 connection cable ADICOS GSME-X20 408-2410-004 EN22...
  • Page 14: Id Plate

    (variable) (variable) ART-Nr: Article number TEMP: Ambient Degree of (variable) temperature protection COM-Nr: Communication /VA: Voltage range / Internal fusing number (variabel) maximum pow- (Short-circuit er consumption current) (heating incl.) CE marking Information on explosion protection 408-2410-004 EN22 ADICOS GSME-X20...
  • Page 15: 10 Appendix

    AppenDix 10 Appendix 10.1 ADICOS Mounting Plate 1 5 0 1 3 0 6 , 4 A - A ADICOS GSME-X20 408-2410-004 EN22...