ZONE DIP Switches
The ZONE DIP switches enable you to control the routing of the IR commands from the IR DATA IN. Your
two routing options include:
• The left ZONE DIP switch controls the routing of IR DATA IN to the Room 1 control module. In the up
position this routing is enabled and Room 1 can be controlled from the IR DATA IN. In the down position
this routing is disabled and Room 1 cannot be controlled by the IR DATA IN (see Figure 21).
to Room 1 control module
• The right ZONE DIP switch controls the routing of IR DATA IN to the DEDICATED FLASHER output. In
the up position this routing is enabled and the dedicated flasher can be controlled from the IR DATA IN. In
the down position this routing is disabled and the dedicated flasher cannot be controlled by the IR DATA
IN (see Figure 21).
Setting the DEFAULTS DIP Switches
The DEFAULTS DIP switches are used to configure various features of the RVL-6.
Choosing Rooms That Respond To An ALL ON Command
The DIP switches labeled ALL ON enable you to individually configure which rooms will respond to the ALL
ON command (see Figure 22). Each room has a corresponding DIP switch (1-6 starting from the left).
• Setting the ALL ON DIP switch in the up position will enable the corresponding room control module to
respond to an ALL ON command.
• Setting the ALL ON DIP switch in the down position will disable the corresponding room control module
from responding to an ALL ON command.
Setting the Turn-On Volume Level
The DIP switch labeled V enables you configure the volume level when a room is turned on (see Figure 23).
• Setting the V DIP switch in the up position will enable all rooms (only one switch), when turned on, to
automatically revert to its previous volume setting.
Controls DATA IN
Figure 21 Zone DIP switches.
1
2
3
4
5
6
Figure 22 ALL ON respond DIP switches.
Turn on with last volume setting
Turn on with 25% volume
Figure 23 Turn-on volume level.
Controls DATA IN
to DEDICATED FLASHER
Enables room to respond to ALL ON
Disables room to respond to ALL ON